{"title":"在梯度反相液相色谱中使用建模软件进行异常保留预测:为什么会发生以及如何预防","authors":"Jennifer K. Field, Melvin R. Euerby, Patrik Petersson, Stuart N. Berry, James Hogbin, Veronica Paget, Earl McKoy, Raymond Wong","doi":"10.56530/lcgc.eu.vg7476d5","DOIUrl":null,"url":null,"abstract":"This article presents the benefits of screening column and mobile phase combinations that generate differing chromatographic selectivities in reversed-phase gradient ultrahigh-pressure liquid chromatographic (UHPLC) method development strategies. Photodiode array (PDA) and mass spectrophotometric (MS) detection was necessary to facilitate peak tracking or identification of components in the sample mixture to build retention models. Retention time prediction accuracies of < 0.3% were obtained from a two-dimensional gradient time vs. temperature model when the initial gradient conditions were maintained. However, anomalous retention predictions were observed when higher %B initial gradient conditions were employed. Polar analytes in the sample mixture that started to migrate down the column in the dwell volume of the UHPLC system produced inaccurate retention time predictions if an inappropriate dwell volume was used in the retention model. An iterative dwell volume estimation was demonstrated to generate more accurate retention time predictions than when a practically determined dwell volume was used. However, to obtain good predictions the analyst should endeavour to use initial chromatographic conditions that promote focusing of all analytes on top of the column (that is, retention factor > 10).","PeriodicalId":49915,"journal":{"name":"LC GC Europe","volume":"21 1","pages":"0"},"PeriodicalIF":0.8000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Anomalous Retention Prediction Using Modelling Software in Gradient Reversed-Phase Liquid Chromatography: Why it Can Occur and How to Prevent It\",\"authors\":\"Jennifer K. Field, Melvin R. Euerby, Patrik Petersson, Stuart N. Berry, James Hogbin, Veronica Paget, Earl McKoy, Raymond Wong\",\"doi\":\"10.56530/lcgc.eu.vg7476d5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article presents the benefits of screening column and mobile phase combinations that generate differing chromatographic selectivities in reversed-phase gradient ultrahigh-pressure liquid chromatographic (UHPLC) method development strategies. Photodiode array (PDA) and mass spectrophotometric (MS) detection was necessary to facilitate peak tracking or identification of components in the sample mixture to build retention models. Retention time prediction accuracies of < 0.3% were obtained from a two-dimensional gradient time vs. temperature model when the initial gradient conditions were maintained. However, anomalous retention predictions were observed when higher %B initial gradient conditions were employed. Polar analytes in the sample mixture that started to migrate down the column in the dwell volume of the UHPLC system produced inaccurate retention time predictions if an inappropriate dwell volume was used in the retention model. An iterative dwell volume estimation was demonstrated to generate more accurate retention time predictions than when a practically determined dwell volume was used. However, to obtain good predictions the analyst should endeavour to use initial chromatographic conditions that promote focusing of all analytes on top of the column (that is, retention factor > 10).\",\"PeriodicalId\":49915,\"journal\":{\"name\":\"LC GC Europe\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"LC GC Europe\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.56530/lcgc.eu.vg7476d5\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"LC GC Europe","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56530/lcgc.eu.vg7476d5","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了在反相梯度超高压液相色谱(UHPLC)方法开发策略中筛选柱和流动相组合产生不同色谱选择性的好处。光电二极管阵列(PDA)和质谱(MS)检测是必要的,以方便峰跟踪或鉴定样品混合物中的成分,以建立保留模型。保留时间预测精度当保持初始梯度条件时,二维梯度时间温度模型得到0.3%。然而,当采用较高的%B初始梯度条件时,观察到异常保留预测。样品混合物中的极性分析物在UHPLC系统的驻留体积中开始向下迁移,如果在保留模型中使用不适当的驻留体积,则会产生不准确的保留时间预测。与实际确定的驻留体积相比,迭代驻留体积估计被证明可以产生更准确的保留时间预测。然而,为了获得良好的预测,分析人员应努力使用初始色谱条件,促进所有分析物集中在色谱柱顶部(即保留系数>10)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Anomalous Retention Prediction Using Modelling Software in Gradient Reversed-Phase Liquid Chromatography: Why it Can Occur and How to Prevent It
This article presents the benefits of screening column and mobile phase combinations that generate differing chromatographic selectivities in reversed-phase gradient ultrahigh-pressure liquid chromatographic (UHPLC) method development strategies. Photodiode array (PDA) and mass spectrophotometric (MS) detection was necessary to facilitate peak tracking or identification of components in the sample mixture to build retention models. Retention time prediction accuracies of < 0.3% were obtained from a two-dimensional gradient time vs. temperature model when the initial gradient conditions were maintained. However, anomalous retention predictions were observed when higher %B initial gradient conditions were employed. Polar analytes in the sample mixture that started to migrate down the column in the dwell volume of the UHPLC system produced inaccurate retention time predictions if an inappropriate dwell volume was used in the retention model. An iterative dwell volume estimation was demonstrated to generate more accurate retention time predictions than when a practically determined dwell volume was used. However, to obtain good predictions the analyst should endeavour to use initial chromatographic conditions that promote focusing of all analytes on top of the column (that is, retention factor > 10).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
LC GC Europe
LC GC Europe 化学-分析化学
CiteScore
0.37
自引率
60.00%
发文量
1
审稿时长
3 months
期刊介绍: Because LCGC is directed to experienced researchers and applications personnel in the field of chromatography, avoid describing details or techniques that are common knowledge among such specialists.
期刊最新文献
Le Corbusier et la ballena : habitar la cubierta de Ronchamp Une introduction à Vers une architecture L’Art décoratif d’aujourd’hui de Le Corbusier. Polémique et théorie critique de « l’aile gauche » de Vers une Architecture Pascal Aumasson, Yves Brand’Honneur. Savina, Le Corbusier. De l’art celtique à la sculpture moderne Entretien avec Jean-Louis Cohen, par Élisabeth Essaïan
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1