{"title":"电阻率层析成像与土工现场数据在土壤剖面表征中的相关性","authors":"Ahmad Khairul Abd Malik, Aziman Madun, Muhammad Nur Hidayat Zahari","doi":"10.30880/jsue.2023.03.01.002","DOIUrl":null,"url":null,"abstract":"This study looked at the effects of compaction on resistivity values as well as the relationship between different degrees of compaction. The material used in this experiment was laterite soil. The sample was tested into a standard proctor mould. The model has 10.20cm diameter and 11.6 cm for height of the mould. Each sample's resistivity was measured entirely compacted.The resistivity testing in this study were conducted using the Miller 400A. ASTM D 422 Standards were used, and for electrical resistivity testing, ASTM G57 is used. This research emphasises the impact of moisture content on resistivity value, as soil reduces resistivity value when the soil has higher moisture content which is 120 Ωm at 37%, and 190 Ωm at 25%. By comparing the results of different moisture content of soil samples under varied degrees of compaction, better resistivity interpretation tables may be generated.","PeriodicalId":277750,"journal":{"name":"Journal of Sustainable Underground Exploration","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Correlation of Electrical Resistivity Tomography and Geotechnical Field Data for Soil Profile Characterization\",\"authors\":\"Ahmad Khairul Abd Malik, Aziman Madun, Muhammad Nur Hidayat Zahari\",\"doi\":\"10.30880/jsue.2023.03.01.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study looked at the effects of compaction on resistivity values as well as the relationship between different degrees of compaction. The material used in this experiment was laterite soil. The sample was tested into a standard proctor mould. The model has 10.20cm diameter and 11.6 cm for height of the mould. Each sample's resistivity was measured entirely compacted.The resistivity testing in this study were conducted using the Miller 400A. ASTM D 422 Standards were used, and for electrical resistivity testing, ASTM G57 is used. This research emphasises the impact of moisture content on resistivity value, as soil reduces resistivity value when the soil has higher moisture content which is 120 Ωm at 37%, and 190 Ωm at 25%. By comparing the results of different moisture content of soil samples under varied degrees of compaction, better resistivity interpretation tables may be generated.\",\"PeriodicalId\":277750,\"journal\":{\"name\":\"Journal of Sustainable Underground Exploration\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Sustainable Underground Exploration\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30880/jsue.2023.03.01.002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sustainable Underground Exploration","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30880/jsue.2023.03.01.002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本研究考察了压实对电阻率值的影响以及不同压实程度之间的关系。本实验所用材料为红土。样品在标准普罗克特模具中进行了测试。模型直径10.20厘米,模具高度11.6厘米。每个样品的电阻率测量完全压实。本研究的电阻率测试采用Miller 400A进行。采用ASTM D 422标准,电阻率测试采用ASTM G57标准。本研究强调含水率对电阻率值的影响,土壤含水率较高时电阻率值降低,含水率为120 Ωm(37%),含水率为190 Ωm(25%)。通过比较不同压实程度下土样不同含水率的结果,可以得到更好的电阻率解释表。
Correlation of Electrical Resistivity Tomography and Geotechnical Field Data for Soil Profile Characterization
This study looked at the effects of compaction on resistivity values as well as the relationship between different degrees of compaction. The material used in this experiment was laterite soil. The sample was tested into a standard proctor mould. The model has 10.20cm diameter and 11.6 cm for height of the mould. Each sample's resistivity was measured entirely compacted.The resistivity testing in this study were conducted using the Miller 400A. ASTM D 422 Standards were used, and for electrical resistivity testing, ASTM G57 is used. This research emphasises the impact of moisture content on resistivity value, as soil reduces resistivity value when the soil has higher moisture content which is 120 Ωm at 37%, and 190 Ωm at 25%. By comparing the results of different moisture content of soil samples under varied degrees of compaction, better resistivity interpretation tables may be generated.