José Alberto Rodríguez Agudo, Jan Haeberle, Michael Müller-Pabel, Alexander Troiss, Abhishek Shetty, Joachim Kaschta, Christopher Giehl
{"title":"用一种新型扭轴复合流变仪表征复泊松比的温度和频率依赖性","authors":"José Alberto Rodríguez Agudo, Jan Haeberle, Michael Müller-Pabel, Alexander Troiss, Abhishek Shetty, Joachim Kaschta, Christopher Giehl","doi":"10.1122/8.0000675","DOIUrl":null,"url":null,"abstract":"This study discusses the feasibility of using a combined torsional-axial rheometer to indirectly measure the complex Poisson’s ratio based on shear and Young’s modulus. For this purpose, isothermal frequency sweeps in torsion and extension are performed sequentially on the same cylindrical specimen and under the same environmental conditions. The method is tested on two amorphous polymers, a semicrystalline polymer, a polymer blend, and a copolymer. The article includes an extensive literature review and an uncertainty assessment of the method to provide a basis for subsequent data comparison with existing research. The experimental data show a monotonic increase in the complex Poisson’s ratio up to 0.5 as the temperature approaches α-relaxation for all samples, except for the amorphous polymer. The latter shows a local minimum in the complex Poisson’s ratio observed near α-relaxation, which disappears after thermal annealing of the sample above the α-relaxation temperature. The real and imaginary parts of the complex Poisson’s ratio are additionally determined by evaluating both phase shift angles from torsional and extensional measurements. All polymers show a certain offset between the torsional and extensional phase shift angles in the glassy state, which gradually decreases as the temperature approaches α-relaxation. The complex Poisson’s ratio results are in good agreement with the literature data obtained by existing methods. This confirms that the method is applicable to polymers up to α-relaxation temperatures with significant time savings due to the nondestructive approach. This is of particular interest, given the limited availability of data in the literature.","PeriodicalId":16991,"journal":{"name":"Journal of Rheology","volume":"34 2","pages":"0"},"PeriodicalIF":3.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characterization of the temperature and frequency dependency of the complex Poisson’s ratio using a novel combined torsional-axial rheometer\",\"authors\":\"José Alberto Rodríguez Agudo, Jan Haeberle, Michael Müller-Pabel, Alexander Troiss, Abhishek Shetty, Joachim Kaschta, Christopher Giehl\",\"doi\":\"10.1122/8.0000675\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study discusses the feasibility of using a combined torsional-axial rheometer to indirectly measure the complex Poisson’s ratio based on shear and Young’s modulus. For this purpose, isothermal frequency sweeps in torsion and extension are performed sequentially on the same cylindrical specimen and under the same environmental conditions. The method is tested on two amorphous polymers, a semicrystalline polymer, a polymer blend, and a copolymer. The article includes an extensive literature review and an uncertainty assessment of the method to provide a basis for subsequent data comparison with existing research. The experimental data show a monotonic increase in the complex Poisson’s ratio up to 0.5 as the temperature approaches α-relaxation for all samples, except for the amorphous polymer. The latter shows a local minimum in the complex Poisson’s ratio observed near α-relaxation, which disappears after thermal annealing of the sample above the α-relaxation temperature. The real and imaginary parts of the complex Poisson’s ratio are additionally determined by evaluating both phase shift angles from torsional and extensional measurements. All polymers show a certain offset between the torsional and extensional phase shift angles in the glassy state, which gradually decreases as the temperature approaches α-relaxation. The complex Poisson’s ratio results are in good agreement with the literature data obtained by existing methods. This confirms that the method is applicable to polymers up to α-relaxation temperatures with significant time savings due to the nondestructive approach. This is of particular interest, given the limited availability of data in the literature.\",\"PeriodicalId\":16991,\"journal\":{\"name\":\"Journal of Rheology\",\"volume\":\"34 2\",\"pages\":\"0\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Rheology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1122/8.0000675\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MECHANICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rheology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1122/8.0000675","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MECHANICS","Score":null,"Total":0}
Characterization of the temperature and frequency dependency of the complex Poisson’s ratio using a novel combined torsional-axial rheometer
This study discusses the feasibility of using a combined torsional-axial rheometer to indirectly measure the complex Poisson’s ratio based on shear and Young’s modulus. For this purpose, isothermal frequency sweeps in torsion and extension are performed sequentially on the same cylindrical specimen and under the same environmental conditions. The method is tested on two amorphous polymers, a semicrystalline polymer, a polymer blend, and a copolymer. The article includes an extensive literature review and an uncertainty assessment of the method to provide a basis for subsequent data comparison with existing research. The experimental data show a monotonic increase in the complex Poisson’s ratio up to 0.5 as the temperature approaches α-relaxation for all samples, except for the amorphous polymer. The latter shows a local minimum in the complex Poisson’s ratio observed near α-relaxation, which disappears after thermal annealing of the sample above the α-relaxation temperature. The real and imaginary parts of the complex Poisson’s ratio are additionally determined by evaluating both phase shift angles from torsional and extensional measurements. All polymers show a certain offset between the torsional and extensional phase shift angles in the glassy state, which gradually decreases as the temperature approaches α-relaxation. The complex Poisson’s ratio results are in good agreement with the literature data obtained by existing methods. This confirms that the method is applicable to polymers up to α-relaxation temperatures with significant time savings due to the nondestructive approach. This is of particular interest, given the limited availability of data in the literature.
期刊介绍:
The Journal of Rheology, formerly the Transactions of The Society of Rheology, is published six times per year by The Society of Rheology, a member society of the American Institute of Physics, through AIP Publishing. It provides in-depth interdisciplinary coverage of theoretical and experimental issues drawn from industry and academia. The Journal of Rheology is published for professionals and students in chemistry, physics, engineering, material science, and mathematics.