立式百叶窗的热特性

Q4 Environmental Science Journal of Environmental Engineering (Japan) Pub Date : 2023-10-01 DOI:10.3130/aije.88.789
Kyoichiro ISOZAKI, Hitoshi TAKEDA
{"title":"立式百叶窗的热特性","authors":"Kyoichiro ISOZAKI, Hitoshi TAKEDA","doi":"10.3130/aije.88.789","DOIUrl":null,"url":null,"abstract":"By using Radiance and the thermal resistance value between vertical blind and glass, it is possible to calculate the cooling and heating load at any azimuth angle of the vertical blind. We created the 2010s reference weather data from the Tokyo 2010-2019 meteorological data. This time, using the newly created meteorological data, a vertical blind is installed at opening of the office building, and a cooling/heating load simulation is performed by automatic control. As a result, the greatest effect of reducing the cooling load is the minimum heat gain control.","PeriodicalId":38500,"journal":{"name":"Journal of Environmental Engineering (Japan)","volume":"240 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"縦型ブラインドの熱特性\",\"authors\":\"Kyoichiro ISOZAKI, Hitoshi TAKEDA\",\"doi\":\"10.3130/aije.88.789\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"By using Radiance and the thermal resistance value between vertical blind and glass, it is possible to calculate the cooling and heating load at any azimuth angle of the vertical blind. We created the 2010s reference weather data from the Tokyo 2010-2019 meteorological data. This time, using the newly created meteorological data, a vertical blind is installed at opening of the office building, and a cooling/heating load simulation is performed by automatic control. As a result, the greatest effect of reducing the cooling load is the minimum heat gain control.\",\"PeriodicalId\":38500,\"journal\":{\"name\":\"Journal of Environmental Engineering (Japan)\",\"volume\":\"240 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Environmental Engineering (Japan)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3130/aije.88.789\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Engineering (Japan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3130/aije.88.789","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 0

摘要

利用辐亮度和垂直百叶窗与玻璃之间的热阻值,可以计算出垂直百叶窗任意方位角下的冷热负荷。我们从东京2010-2019年的气象数据中创建了2010年代的参考天气数据。这次,利用新创建的气象数据,在办公楼的开口处安装垂直百叶窗,并通过自动控制进行冷热负荷模拟。因此,减少冷却负荷的最大效果是最小的热增益控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
縦型ブラインドの熱特性
By using Radiance and the thermal resistance value between vertical blind and glass, it is possible to calculate the cooling and heating load at any azimuth angle of the vertical blind. We created the 2010s reference weather data from the Tokyo 2010-2019 meteorological data. This time, using the newly created meteorological data, a vertical blind is installed at opening of the office building, and a cooling/heating load simulation is performed by automatic control. As a result, the greatest effect of reducing the cooling load is the minimum heat gain control.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Environmental Engineering (Japan)
Journal of Environmental Engineering (Japan) Environmental Science-Environmental Engineering
CiteScore
0.70
自引率
0.00%
发文量
77
期刊最新文献
宿泊施設の衛生的環境に関する実態調査 PROPOSAL AND CONSIDERATION OF SPATIAL PERFORMANCE EVALUATION METHOD FOR ELECTROMAGNETIC SHIELDING ROOM パーソナル空調の操作性が執務者の熱的快適性・知的生産性に与える影響 A STUDY ON THE DIFFERENCES OF EVALUATION STRUCTURE BETWEEN CYCLISTS IN TOURISM AND DAILY TRANSPORTATION ON RIVERSIDE ROAD EFFECTS OF ARTIFICIAL WINDOW IN AN ENCLOSED PERSONALIZED WORK ENVIRONMENT ON USERS’ PSYCHOLOGY AND PRODUCTIVITY
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1