实际可行的嵌入式传感器动态评估钢琴系统,用于量化钢琴演奏过程中数字的冲击力

IF 1.6 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Medical and Biological Engineering Pub Date : 2023-11-07 DOI:10.1007/s40846-023-00835-7
Kuan-Yin Lai, Chieh-Hsiang Hsu, Yu-Chen Lin, Chung-Hung Tsai, Cheng-Feng Lin, Li-Chieh Kuo, Fong-Chin Su
{"title":"实际可行的嵌入式传感器动态评估钢琴系统,用于量化钢琴演奏过程中数字的冲击力","authors":"Kuan-Yin Lai, Chieh-Hsiang Hsu, Yu-Chen Lin, Chung-Hung Tsai, Cheng-Feng Lin, Li-Chieh Kuo, Fong-Chin Su","doi":"10.1007/s40846-023-00835-7","DOIUrl":null,"url":null,"abstract":"Abstract Purpose Understanding the pathogenesis of playing-related hand disorders through investigations based on coordination and biomechanical perspectives is indispensable. This study aimed to establish a sensor-embedded kinetic assessment piano system (SeKAPS) and conduct reliability and validity tests for this system. In addition, the differences in digit coordination between professional pianists and non-musicians were investigated. Methods Twelve subminiature load cells were embedded in the middle of the 12 corresponding keys of an upright piano. A customized calibrated system with a load cell was used to establish the criterion-related validity of the SeKAPS. The reliability of the SeKAPS was determined by 22 volunteer pianists. The other ten professional pianists and ten non-musicians were recruited to indicate the feasibility of the SeKAPS to distinguish the performing differences between groups. Results The R 2 values of regression analyses for the load cells were 0.993–0.999 ( p < 0.001), indicating high validity. The ICC values of the modified keys were 0.82–0.93, indicating high reliability. The results indicate that SeKAPS is accurate in detecting the striking force of digits during piano playing. Significant differences existed in the mean peak force and mean CVs of the peak force of the specific digits between the two groups. The results showed differences in finger control strategies between the pianists and non-musicians. Conclusion The SeKAPS may provide a valuable assessment for assisting pianists in understanding digit force control and movement strategies to achieve efficient digit coordination.","PeriodicalId":50133,"journal":{"name":"Journal of Medical and Biological Engineering","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2023-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Practically Feasible Sensor-Embedded Kinetic Assessment Piano System for Quantifying Striking Force of Digits During Piano Playing\",\"authors\":\"Kuan-Yin Lai, Chieh-Hsiang Hsu, Yu-Chen Lin, Chung-Hung Tsai, Cheng-Feng Lin, Li-Chieh Kuo, Fong-Chin Su\",\"doi\":\"10.1007/s40846-023-00835-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Purpose Understanding the pathogenesis of playing-related hand disorders through investigations based on coordination and biomechanical perspectives is indispensable. This study aimed to establish a sensor-embedded kinetic assessment piano system (SeKAPS) and conduct reliability and validity tests for this system. In addition, the differences in digit coordination between professional pianists and non-musicians were investigated. Methods Twelve subminiature load cells were embedded in the middle of the 12 corresponding keys of an upright piano. A customized calibrated system with a load cell was used to establish the criterion-related validity of the SeKAPS. The reliability of the SeKAPS was determined by 22 volunteer pianists. The other ten professional pianists and ten non-musicians were recruited to indicate the feasibility of the SeKAPS to distinguish the performing differences between groups. Results The R 2 values of regression analyses for the load cells were 0.993–0.999 ( p < 0.001), indicating high validity. The ICC values of the modified keys were 0.82–0.93, indicating high reliability. The results indicate that SeKAPS is accurate in detecting the striking force of digits during piano playing. Significant differences existed in the mean peak force and mean CVs of the peak force of the specific digits between the two groups. The results showed differences in finger control strategies between the pianists and non-musicians. Conclusion The SeKAPS may provide a valuable assessment for assisting pianists in understanding digit force control and movement strategies to achieve efficient digit coordination.\",\"PeriodicalId\":50133,\"journal\":{\"name\":\"Journal of Medical and Biological Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical and Biological Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s40846-023-00835-7\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical and Biological Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40846-023-00835-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

目的从协调性和生物力学的角度研究游戏相关手部疾病的发病机制是必不可少的。本研究旨在建立传感器嵌入式钢琴动力学评估系统(SeKAPS),并对该系统进行信度和效度检验。此外,研究了专业钢琴家和非音乐家在手指协调方面的差异。方法在立式钢琴的12个对应琴键中间嵌入12个微型测压元件。使用带有称重传感器的定制校准系统来建立SeKAPS与标准相关的有效性。SeKAPS的可靠性是由22名志愿钢琴家确定的。另外10名专业钢琴家和10名非音乐家被招募来表明SeKAPS区分不同群体之间演奏差异的可行性。结果测压元件回归分析的r2值为0.993 ~ 0.999 (p <0.001),表明高效度。修改后的密钥ICC值为0.82 ~ 0.93,可靠性较高。结果表明,SeKAPS在钢琴弹奏过程中数字敲击力的检测是准确的。两组在具体指的平均峰值力和平均峰值力cv上存在显著差异。结果显示,钢琴家和非音乐家在手指控制策略上存在差异。结论SeKAPS可以帮助钢琴家了解手指力量控制和运动策略,以达到有效的手指协调。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Practically Feasible Sensor-Embedded Kinetic Assessment Piano System for Quantifying Striking Force of Digits During Piano Playing
Abstract Purpose Understanding the pathogenesis of playing-related hand disorders through investigations based on coordination and biomechanical perspectives is indispensable. This study aimed to establish a sensor-embedded kinetic assessment piano system (SeKAPS) and conduct reliability and validity tests for this system. In addition, the differences in digit coordination between professional pianists and non-musicians were investigated. Methods Twelve subminiature load cells were embedded in the middle of the 12 corresponding keys of an upright piano. A customized calibrated system with a load cell was used to establish the criterion-related validity of the SeKAPS. The reliability of the SeKAPS was determined by 22 volunteer pianists. The other ten professional pianists and ten non-musicians were recruited to indicate the feasibility of the SeKAPS to distinguish the performing differences between groups. Results The R 2 values of regression analyses for the load cells were 0.993–0.999 ( p < 0.001), indicating high validity. The ICC values of the modified keys were 0.82–0.93, indicating high reliability. The results indicate that SeKAPS is accurate in detecting the striking force of digits during piano playing. Significant differences existed in the mean peak force and mean CVs of the peak force of the specific digits between the two groups. The results showed differences in finger control strategies between the pianists and non-musicians. Conclusion The SeKAPS may provide a valuable assessment for assisting pianists in understanding digit force control and movement strategies to achieve efficient digit coordination.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.30
自引率
5.00%
发文量
81
审稿时长
3 months
期刊介绍: The purpose of Journal of Medical and Biological Engineering, JMBE, is committed to encouraging and providing the standard of biomedical engineering. The journal is devoted to publishing papers related to clinical engineering, biomedical signals, medical imaging, bio-informatics, tissue engineering, and so on. Other than the above articles, any contributions regarding hot issues and technological developments that help reach the purpose are also included.
期刊最新文献
Influence of Different Stages of Post-Traumatic Elbow Joint Capsule Healing on Pronation Movement Attribute and Malignancy Analysis of Lung Nodule on Chest CT with Cause-and-Effect Logic Biomechanical Performance of Different Implant Spacings and Placement Angles in Partial Fixed Denture Prosthesis Restorations: A Finite Element Analysis Enhancing Myocardial Infarction Diagnosis: LSTM-based Deep Learning Approach Integrating Echocardiographic Wall Motion Analysis Investigation of Image Quality for Cuboid and Tapered Array microPET Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1