ITM 68Ge/68Ga发电机推荐保质期后的有效性和安全性评估

Q3 Medicine Siriraj Medical Journal Pub Date : 2023-10-01 DOI:10.33192/smj.v75i10.264289
Tossaporn Sriprapa, Thanete Doungta, Nopparath Sakulsamart, Nilmanee Taweewatthanasopon, Lanyawat Madputeh, Pitima Ragchana, Napamon Sritongkul, Malulee Tantawiroon, Somlak Kongmuang, Benjapa Khiewvan, Shuichi Shiratori
{"title":"ITM 68Ge/68Ga发电机推荐保质期后的有效性和安全性评估","authors":"Tossaporn Sriprapa, Thanete Doungta, Nopparath Sakulsamart, Nilmanee Taweewatthanasopon, Lanyawat Madputeh, Pitima Ragchana, Napamon Sritongkul, Malulee Tantawiroon, Somlak Kongmuang, Benjapa Khiewvan, Shuichi Shiratori","doi":"10.33192/smj.v75i10.264289","DOIUrl":null,"url":null,"abstract":"Objective: 68Ga can be routinely produced by a 68Ge/68Ga generator without the need for a cyclotron. It is recommended to replace the 68Ge/68Ga generator after 250 elutions or 12 months of shelf-life whichever endpoint is reached first. However, a 68Ge/68Ga generator that has gone past its recommended lifespan can still be further used as a 68Ga source for 68Ga-labeled radiopharmaceuticals for use in animal experiments. To ensure the quality of 68Ga eluates, we aimed to evaluate the efficacy and safety of the ITM (Isotope Technologies München) 68Ge/68Ga generator in our institute after its recommended shelf-life. Materials and Methods: A 21-month-old ITM 68Ge/68Ga generator was eluted using 4.0 ml of 0.05 M HCl. The 68Ga elution yields were calculated, and 68Ge breakthrough was measured at least 48 h after elution in an aliquot amount using a multichannel analyzer (MCA) with a high-purity germanium probe. Metal impurities in the 68Ga eluates were analyzed by ICP-MS. Results: The elution yield of 68Ga was 35.2 ± 8.1%; n = 5 (decay corrected). 68Ge breakthrough from the ITM 68Ge/68Ga generator was below the detectable level. The average amounts of the metallic ions 57Fe, 66Zn, 203Pb, 60Ni, and 63Cu were 18.60, 9.86, 2.42, 0.52, and 0.47 µg/GBq, respectively. Conclusion: The ITM 68Ge/68Ga generator demonstrated consistent and reliable 68Ga elution profiles with an absence of either 68Ge breakthrough or other metal contaminants in the eluent samples as verified by the manufacturer. The use of the ITM 68Ge/68Ga generator could be extended past its recommended shelf-life to prepare 68Ga radiopharmaceuticals that are considered safe and suitable for use in animal experimentation and other applications.","PeriodicalId":37270,"journal":{"name":"Siriraj Medical Journal","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Efficacy and Safety of the ITM 68Ge/68Ga Generator After its Recommended Shelf-life\",\"authors\":\"Tossaporn Sriprapa, Thanete Doungta, Nopparath Sakulsamart, Nilmanee Taweewatthanasopon, Lanyawat Madputeh, Pitima Ragchana, Napamon Sritongkul, Malulee Tantawiroon, Somlak Kongmuang, Benjapa Khiewvan, Shuichi Shiratori\",\"doi\":\"10.33192/smj.v75i10.264289\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: 68Ga can be routinely produced by a 68Ge/68Ga generator without the need for a cyclotron. It is recommended to replace the 68Ge/68Ga generator after 250 elutions or 12 months of shelf-life whichever endpoint is reached first. However, a 68Ge/68Ga generator that has gone past its recommended lifespan can still be further used as a 68Ga source for 68Ga-labeled radiopharmaceuticals for use in animal experiments. To ensure the quality of 68Ga eluates, we aimed to evaluate the efficacy and safety of the ITM (Isotope Technologies München) 68Ge/68Ga generator in our institute after its recommended shelf-life. Materials and Methods: A 21-month-old ITM 68Ge/68Ga generator was eluted using 4.0 ml of 0.05 M HCl. The 68Ga elution yields were calculated, and 68Ge breakthrough was measured at least 48 h after elution in an aliquot amount using a multichannel analyzer (MCA) with a high-purity germanium probe. Metal impurities in the 68Ga eluates were analyzed by ICP-MS. Results: The elution yield of 68Ga was 35.2 ± 8.1%; n = 5 (decay corrected). 68Ge breakthrough from the ITM 68Ge/68Ga generator was below the detectable level. The average amounts of the metallic ions 57Fe, 66Zn, 203Pb, 60Ni, and 63Cu were 18.60, 9.86, 2.42, 0.52, and 0.47 µg/GBq, respectively. Conclusion: The ITM 68Ge/68Ga generator demonstrated consistent and reliable 68Ga elution profiles with an absence of either 68Ge breakthrough or other metal contaminants in the eluent samples as verified by the manufacturer. The use of the ITM 68Ge/68Ga generator could be extended past its recommended shelf-life to prepare 68Ga radiopharmaceuticals that are considered safe and suitable for use in animal experimentation and other applications.\",\"PeriodicalId\":37270,\"journal\":{\"name\":\"Siriraj Medical Journal\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Siriraj Medical Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33192/smj.v75i10.264289\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Siriraj Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33192/smj.v75i10.264289","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:68Ga可以在不需要回旋加速器的情况下由68Ge/68Ga发生器常规产生。建议在250次洗脱或保质期12个月后更换68Ge/68Ga发生器,以先达到的终点为准。然而,超过其推荐寿命的68Ge/68Ga发生器仍然可以进一步用作68Ga标记的放射性药物的68Ga源,用于动物实验。为了确保68Ga洗脱液的质量,我们旨在评估ITM(同位素技术公司)68Ge/68Ga发生器在推荐保质期后的有效性和安全性。材料与方法:用4.0 ml 0.05 M HCl洗脱21个月的ITM 68Ge/68Ga发生器。计算68Ga的洗脱率,并在等量洗脱后至少48 h,使用带有高纯度锗探针的多通道分析仪(MCA)测量68Ge的突破。用ICP-MS对68Ga洗脱液中的金属杂质进行了分析。结果:68Ga的洗脱率为35.2±8.1%;N = 5(衰减修正)。ITM 68Ge/68Ga发生器的68Ge突破低于可检测水平。金属离子57Fe、66Zn、203Pb、60Ni和63Cu的平均含量分别为18.60、9.86、2.42、0.52和0.47µg/GBq。结论:ITM 68Ge/68Ga发生器显示出一致和可靠的68Ga洗脱剖面,并且经制造商验证,洗脱样品中没有68Ge突破或其他金属污染物。ITM 68Ge/68Ga发生器的使用可以延长其推荐的保质期,以制备被认为安全且适合用于动物实验和其他应用的68Ga放射性药物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the Efficacy and Safety of the ITM 68Ge/68Ga Generator After its Recommended Shelf-life
Objective: 68Ga can be routinely produced by a 68Ge/68Ga generator without the need for a cyclotron. It is recommended to replace the 68Ge/68Ga generator after 250 elutions or 12 months of shelf-life whichever endpoint is reached first. However, a 68Ge/68Ga generator that has gone past its recommended lifespan can still be further used as a 68Ga source for 68Ga-labeled radiopharmaceuticals for use in animal experiments. To ensure the quality of 68Ga eluates, we aimed to evaluate the efficacy and safety of the ITM (Isotope Technologies München) 68Ge/68Ga generator in our institute after its recommended shelf-life. Materials and Methods: A 21-month-old ITM 68Ge/68Ga generator was eluted using 4.0 ml of 0.05 M HCl. The 68Ga elution yields were calculated, and 68Ge breakthrough was measured at least 48 h after elution in an aliquot amount using a multichannel analyzer (MCA) with a high-purity germanium probe. Metal impurities in the 68Ga eluates were analyzed by ICP-MS. Results: The elution yield of 68Ga was 35.2 ± 8.1%; n = 5 (decay corrected). 68Ge breakthrough from the ITM 68Ge/68Ga generator was below the detectable level. The average amounts of the metallic ions 57Fe, 66Zn, 203Pb, 60Ni, and 63Cu were 18.60, 9.86, 2.42, 0.52, and 0.47 µg/GBq, respectively. Conclusion: The ITM 68Ge/68Ga generator demonstrated consistent and reliable 68Ga elution profiles with an absence of either 68Ge breakthrough or other metal contaminants in the eluent samples as verified by the manufacturer. The use of the ITM 68Ge/68Ga generator could be extended past its recommended shelf-life to prepare 68Ga radiopharmaceuticals that are considered safe and suitable for use in animal experimentation and other applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Siriraj Medical Journal
Siriraj Medical Journal Medicine-Medicine (all)
CiteScore
0.90
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
Incidences, Characteristics, Management and Outcomes of Different Subtypes of Postoperative Delirium in Elderly Patients Admitted to the Surgical Intensive Care Unit: A Secondary Analysis of a Prospective Cohort Study Optimizing Perioperative Care for Elderly Surgical Patients: A Review of Strategies and Evidence-Based Practices Comparison between the Standard Teaching and the Thai Version of Blended Teaching on Basic Airway Management in Siriraj Medical Students Analgesic Efficacy of Ultrasound-guided Fascia Iliaca Compartment Block (FICB) and Outcomes in Preoperative Fast-track Geriatric Patients with Hip Fracture: A Single-center Retrospective Study Effectiveness of Smartphone Applications vs Conventional Care in Warfarin Therapy: A Randomized Controlled Trial on the Time in the Therapeutic Range
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1