{"title":"紫外光微束扫描与无透镜紫外光微束镜振镜显微镜:从研究仪器的历史到现代机电光学系统的工程","authors":"","doi":"10.33140/jsndc.03.01.06","DOIUrl":null,"url":null,"abstract":"This article aims to ensure continuity between classical methods of ul-traviolet microscopy or/and micromanipulation using ultraviolet mi-crobeam and lens-less ultraviolet microscopy and microbeam exposure of cells and tissues. Considering the history of the development of the method and the possibility of working with different methods of mechanical scanning, the authors propose to use mirror galvanometers and an electromechanical scanning system in the mechanical engineering of lensless microbeam installations. These installations make it possible to provide both scanning with an ultraviolet microbeam to obtain a line scan image, and precision micromanipulation at the level of individual cells or individual organelles (in the case of large cells). We propose to extrapolate mathematical models previously developed for galvanic mirrors of light-beam oscilloscopes for microbeam scanning systems, position-sensitive micromanipulation, and real-time microphotometric cell analysis.","PeriodicalId":91517,"journal":{"name":"International journal of sensor networks and data communications","volume":"106 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Towards Ultraviolet Microbeam Scanning and Lens-Less UV Microbeam Microscopy with Mirror Galvanometric Scanners: From the History of Research Instrumentation to Engineering of Modern Mechatronic Optical Systems\",\"authors\":\"\",\"doi\":\"10.33140/jsndc.03.01.06\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article aims to ensure continuity between classical methods of ul-traviolet microscopy or/and micromanipulation using ultraviolet mi-crobeam and lens-less ultraviolet microscopy and microbeam exposure of cells and tissues. Considering the history of the development of the method and the possibility of working with different methods of mechanical scanning, the authors propose to use mirror galvanometers and an electromechanical scanning system in the mechanical engineering of lensless microbeam installations. These installations make it possible to provide both scanning with an ultraviolet microbeam to obtain a line scan image, and precision micromanipulation at the level of individual cells or individual organelles (in the case of large cells). We propose to extrapolate mathematical models previously developed for galvanic mirrors of light-beam oscilloscopes for microbeam scanning systems, position-sensitive micromanipulation, and real-time microphotometric cell analysis.\",\"PeriodicalId\":91517,\"journal\":{\"name\":\"International journal of sensor networks and data communications\",\"volume\":\"106 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of sensor networks and data communications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33140/jsndc.03.01.06\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of sensor networks and data communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33140/jsndc.03.01.06","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Towards Ultraviolet Microbeam Scanning and Lens-Less UV Microbeam Microscopy with Mirror Galvanometric Scanners: From the History of Research Instrumentation to Engineering of Modern Mechatronic Optical Systems
This article aims to ensure continuity between classical methods of ul-traviolet microscopy or/and micromanipulation using ultraviolet mi-crobeam and lens-less ultraviolet microscopy and microbeam exposure of cells and tissues. Considering the history of the development of the method and the possibility of working with different methods of mechanical scanning, the authors propose to use mirror galvanometers and an electromechanical scanning system in the mechanical engineering of lensless microbeam installations. These installations make it possible to provide both scanning with an ultraviolet microbeam to obtain a line scan image, and precision micromanipulation at the level of individual cells or individual organelles (in the case of large cells). We propose to extrapolate mathematical models previously developed for galvanic mirrors of light-beam oscilloscopes for microbeam scanning systems, position-sensitive micromanipulation, and real-time microphotometric cell analysis.