用碘包覆铂电极差分脉冲伏安法测定血清和尿液样本中的多巴胺

IF 1.1 Q4 PHARMACOLOGY & PHARMACY Pharmacia Pub Date : 2023-10-05 DOI:10.3897/pharmacia.70.e110336
Wafa Hourani, Mohammad Amayreh, Mohammed Khair Hourani
{"title":"用碘包覆铂电极差分脉冲伏安法测定血清和尿液样本中的多巴胺","authors":"Wafa Hourani, Mohammad Amayreh, Mohammed Khair Hourani","doi":"10.3897/pharmacia.70.e110336","DOIUrl":null,"url":null,"abstract":"While platinum electrode shows hyperactivity towards adsorption and surface processes, iodine-coated platinum electrode offers remarkable inertness toward them. Therefore, iodine-coated platinum electrodes lend themselves to probe chemical species in the bulk solution without intervention from adsorption and surface processes. The current work presents utilization of iodine-coated polycrystalline platinum electrode as a voltammetric sensor for determination of dopamine in serum and urine samples. Differential pulse voltammetry (DPV) at iodine coated polycrystalline platinum electrode is the technique of choice whenever higher sensitivity is sought. DPV with a scan rate of 5 mV/s was applied for determination of dopamine in PBS at pH 7. The anodic peak related to dopamine oxidation in the above-mentioned solution was centered at ~0.1V vs. Ag/AgCl quasi reference electrode. The linear range for the developed method was between 1.0 and 100 µM. The anodic peak current showed excellent linearity with dopamine concentration (R 2 =0.9977) over the above-mentioned range. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.29 µM and 0.96 µM respectively which attests to the high sensitivity of the developed method. The proposed method was successfully applied to the analysis of dopamine in serum and urine samples. The percent recovery values ranged from 94.4 to 104.5% attesting to the accuracy of the developed method and absence of determinate errors.","PeriodicalId":20086,"journal":{"name":"Pharmacia","volume":"27 1","pages":"0"},"PeriodicalIF":1.1000,"publicationDate":"2023-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of dopamine in blood serum and urine samples by differential pulse voltammetry at an iodine-coated platinum electrode\",\"authors\":\"Wafa Hourani, Mohammad Amayreh, Mohammed Khair Hourani\",\"doi\":\"10.3897/pharmacia.70.e110336\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"While platinum electrode shows hyperactivity towards adsorption and surface processes, iodine-coated platinum electrode offers remarkable inertness toward them. Therefore, iodine-coated platinum electrodes lend themselves to probe chemical species in the bulk solution without intervention from adsorption and surface processes. The current work presents utilization of iodine-coated polycrystalline platinum electrode as a voltammetric sensor for determination of dopamine in serum and urine samples. Differential pulse voltammetry (DPV) at iodine coated polycrystalline platinum electrode is the technique of choice whenever higher sensitivity is sought. DPV with a scan rate of 5 mV/s was applied for determination of dopamine in PBS at pH 7. The anodic peak related to dopamine oxidation in the above-mentioned solution was centered at ~0.1V vs. Ag/AgCl quasi reference electrode. The linear range for the developed method was between 1.0 and 100 µM. The anodic peak current showed excellent linearity with dopamine concentration (R 2 =0.9977) over the above-mentioned range. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.29 µM and 0.96 µM respectively which attests to the high sensitivity of the developed method. The proposed method was successfully applied to the analysis of dopamine in serum and urine samples. The percent recovery values ranged from 94.4 to 104.5% attesting to the accuracy of the developed method and absence of determinate errors.\",\"PeriodicalId\":20086,\"journal\":{\"name\":\"Pharmacia\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmacia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3897/pharmacia.70.e110336\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmacia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3897/pharmacia.70.e110336","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

铂电极对吸附和表面过程表现出高活性,而碘包覆铂电极对吸附和表面过程表现出明显的惰性。因此,碘包覆铂电极可以在不受吸附和表面过程干预的情况下探测大块溶液中的化学物质。目前的工作是利用碘包覆的多晶铂电极作为伏安传感器来测定血清和尿液样本中的多巴胺。在碘包覆多晶铂电极上的差分脉冲伏安法(DPV)是寻求更高灵敏度的首选技术。采用扫描速率为5 mV/s的DPV检测pH为7的PBS中多巴胺的含量。与Ag/AgCl准参比电极相比,上述溶液中多巴胺氧化相关的阳极峰集中在~0.1V处。该方法的线性范围为1.0 ~ 100µM。在此范围内,阳极峰电流与多巴胺浓度呈良好的线性关系(r2 =0.9977)。检测限(LOD)和定量限(LOQ)分别为0.29µM和0.96µM,表明该方法具有较高的灵敏度。该方法已成功应用于血清和尿液样本中多巴胺的分析。回收率在94.4 ~ 104.5%之间,证明了所建立方法的准确性和不存在确定误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of dopamine in blood serum and urine samples by differential pulse voltammetry at an iodine-coated platinum electrode
While platinum electrode shows hyperactivity towards adsorption and surface processes, iodine-coated platinum electrode offers remarkable inertness toward them. Therefore, iodine-coated platinum electrodes lend themselves to probe chemical species in the bulk solution without intervention from adsorption and surface processes. The current work presents utilization of iodine-coated polycrystalline platinum electrode as a voltammetric sensor for determination of dopamine in serum and urine samples. Differential pulse voltammetry (DPV) at iodine coated polycrystalline platinum electrode is the technique of choice whenever higher sensitivity is sought. DPV with a scan rate of 5 mV/s was applied for determination of dopamine in PBS at pH 7. The anodic peak related to dopamine oxidation in the above-mentioned solution was centered at ~0.1V vs. Ag/AgCl quasi reference electrode. The linear range for the developed method was between 1.0 and 100 µM. The anodic peak current showed excellent linearity with dopamine concentration (R 2 =0.9977) over the above-mentioned range. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.29 µM and 0.96 µM respectively which attests to the high sensitivity of the developed method. The proposed method was successfully applied to the analysis of dopamine in serum and urine samples. The percent recovery values ranged from 94.4 to 104.5% attesting to the accuracy of the developed method and absence of determinate errors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pharmacia
Pharmacia PHARMACOLOGY & PHARMACY-
CiteScore
2.30
自引率
27.30%
发文量
114
审稿时长
12 weeks
期刊最新文献
Microneedle and drug delivery across the skin: An overview Nephroprotective effects of Equisetum ramosissimum L. extract in streptozotocin-induced diabetic rats Spectroscopic and thermodynamic characterization of the interaction of a new synthesized antitumor drug candidate 2H4MBBH with human serum albumin Amstirdam coffee ameliorates Lp-PLA2 and the inflammatory response in an atherosclerosis rats A 36-year-old woman with a parathyroid cyst
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1