{"title":"卒中容量变化是心脏手术患者植入主动脉内球囊泵后液体反应性的良好预测指标","authors":"Rostislav Enev, Fillip Abedinov, Neda Bakalova, Margarita Atanasova, Nezabravka Chilingirova, Plamen Krastev","doi":"10.7546/crabs.2023.04.14","DOIUrl":null,"url":null,"abstract":"There is a vast body of evidence in favour of individualising fluid therapy using dynamic hemodynamic indices like stroke volume variation (SVV). Patients with implanted intra-aortic balloon pump (IABP) are excluded from this approach because of pulse contour artifacts caused by the pump. The aim of this work is to test whether SVV can be used for fluid responsiveness prediction in these patients. Patients after cardiac surgery with implanted IABP were included in this study. SVV was measured after placing the IABP on standby mode for one minute. Cardiac output (CO) measurement was obtained via Swan-Ganz catheter before and after a 6 ml/kg fluid challenge. Fluid responsiveness was defined as increase of CO by at least 10%. SVV above 8.5% showed a good correlation with fluid responsiveness. Sensitivity was 95 (95% CI 85 to 100) and specificity 82 (95% CI 72 to 92). SVV had an area under the ROC curve 0.91 (95% CI 0.81 to 1.0) SVV is a good predictor of fluid responsiveness in patients with IABP. SVV should not be excluded as a fluid therapy guide for these patients. Placing the pump on standby for one minute allows obtaining an accurate measurement of this important variable.","PeriodicalId":50652,"journal":{"name":"Comptes Rendus De L Academie Bulgare Des Sciences","volume":"122 1","pages":"0"},"PeriodicalIF":0.3000,"publicationDate":"2023-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stroke Volume Variation is a Good Predictor of Fluid Responsiveness in Cardiac Surgery Patients with Implanted Intra-aortic Balloon Pump\",\"authors\":\"Rostislav Enev, Fillip Abedinov, Neda Bakalova, Margarita Atanasova, Nezabravka Chilingirova, Plamen Krastev\",\"doi\":\"10.7546/crabs.2023.04.14\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There is a vast body of evidence in favour of individualising fluid therapy using dynamic hemodynamic indices like stroke volume variation (SVV). Patients with implanted intra-aortic balloon pump (IABP) are excluded from this approach because of pulse contour artifacts caused by the pump. The aim of this work is to test whether SVV can be used for fluid responsiveness prediction in these patients. Patients after cardiac surgery with implanted IABP were included in this study. SVV was measured after placing the IABP on standby mode for one minute. Cardiac output (CO) measurement was obtained via Swan-Ganz catheter before and after a 6 ml/kg fluid challenge. Fluid responsiveness was defined as increase of CO by at least 10%. SVV above 8.5% showed a good correlation with fluid responsiveness. Sensitivity was 95 (95% CI 85 to 100) and specificity 82 (95% CI 72 to 92). SVV had an area under the ROC curve 0.91 (95% CI 0.81 to 1.0) SVV is a good predictor of fluid responsiveness in patients with IABP. SVV should not be excluded as a fluid therapy guide for these patients. Placing the pump on standby for one minute allows obtaining an accurate measurement of this important variable.\",\"PeriodicalId\":50652,\"journal\":{\"name\":\"Comptes Rendus De L Academie Bulgare Des Sciences\",\"volume\":\"122 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2023-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Comptes Rendus De L Academie Bulgare Des Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7546/crabs.2023.04.14\",\"RegionNum\":4,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Comptes Rendus De L Academie Bulgare Des Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7546/crabs.2023.04.14","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
有大量的证据支持使用动态血流动力学指标如脑卒中容积变化(SVV)进行个体化液体治疗。植入主动脉内球囊泵(IABP)的患者由于泵引起的脉冲轮廓伪影而被排除在该方法之外。这项工作的目的是测试SVV是否可以用于预测这些患者的液体反应性。本研究纳入了心脏手术后植入IABP的患者。将IABP置于待机模式一分钟后测量SVV。心输出量(CO)测量通过Swan-Ganz导管在6 ml/kg液体刺激前后。流体响应性定义为CO增加至少10%。SVV高于8.5%与流体反应性有良好的相关性。敏感性为95 (95% CI 85 ~ 100),特异性为82 (95% CI 72 ~ 92)。SVV的ROC曲线下面积为0.91 (95% CI 0.81 ~ 1.0) SVV是IABP患者液体反应性的良好预测因子。不应排除SVV作为这些患者的液体治疗指南。将泵置于待机状态一分钟,可以获得对这一重要变量的准确测量。
Stroke Volume Variation is a Good Predictor of Fluid Responsiveness in Cardiac Surgery Patients with Implanted Intra-aortic Balloon Pump
There is a vast body of evidence in favour of individualising fluid therapy using dynamic hemodynamic indices like stroke volume variation (SVV). Patients with implanted intra-aortic balloon pump (IABP) are excluded from this approach because of pulse contour artifacts caused by the pump. The aim of this work is to test whether SVV can be used for fluid responsiveness prediction in these patients. Patients after cardiac surgery with implanted IABP were included in this study. SVV was measured after placing the IABP on standby mode for one minute. Cardiac output (CO) measurement was obtained via Swan-Ganz catheter before and after a 6 ml/kg fluid challenge. Fluid responsiveness was defined as increase of CO by at least 10%. SVV above 8.5% showed a good correlation with fluid responsiveness. Sensitivity was 95 (95% CI 85 to 100) and specificity 82 (95% CI 72 to 92). SVV had an area under the ROC curve 0.91 (95% CI 0.81 to 1.0) SVV is a good predictor of fluid responsiveness in patients with IABP. SVV should not be excluded as a fluid therapy guide for these patients. Placing the pump on standby for one minute allows obtaining an accurate measurement of this important variable.
期刊介绍:
Founded in 1948 by academician Georgy Nadjakov, "Comptes rendus de l’Académie bulgare des Sciences" is also known as "Доклади на БАН","Доклады Болгарской академии наук" and "Proceeding of the Bulgarian Academy of Sciences".
If applicable, the name of the journal should be abbreviated as follows: C. R. Acad. Bulg. Sci. (according to ISO)