Gaurav Mittal, Ritesh Garg, Abhishek Rathi, Debi P. Ghatak, Sonu K. Suman
{"title":"圆柱形和锥形牙种植体即刻和延迟放置效果的比较研究:临床前瞻性研究","authors":"Gaurav Mittal, Ritesh Garg, Abhishek Rathi, Debi P. Ghatak, Sonu K. Suman","doi":"10.4103/njms.njms_65_22","DOIUrl":null,"url":null,"abstract":"Introduction: The study deals with improving the understanding of implant design in various situations. Materials and Method: 40 implants were placed out of which 20 were tapered and rest were cylindrical. These were further divided into immediate and delayed settings. The patients were followed upto 6 months and the results were compiled. Result: Statistically significant difference were found between tapered and cylindrical implants in terms of quality of osseointegration and maintenance of crestal bone height. Conclusion: It has been gathered from the study that while delayed placement suggests waiting time period varying between 3 and 6 months, it offers a predictable procedure in terms of visibility, good implant-bone contact, and closure all of which, promote a better outcome for dental implant therapy. Immediate implant placement solution is very viable in reducing the time period involved in dental implant therapy. Apart from few to minimum contraindications, it can be predictably performed.","PeriodicalId":18827,"journal":{"name":"National Journal of Maxillofacial Surgery","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparative study on efficacy of immediate and delayed placement of cylindrical and tapered dental implants: A clinical prospective study\",\"authors\":\"Gaurav Mittal, Ritesh Garg, Abhishek Rathi, Debi P. Ghatak, Sonu K. Suman\",\"doi\":\"10.4103/njms.njms_65_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: The study deals with improving the understanding of implant design in various situations. Materials and Method: 40 implants were placed out of which 20 were tapered and rest were cylindrical. These were further divided into immediate and delayed settings. The patients were followed upto 6 months and the results were compiled. Result: Statistically significant difference were found between tapered and cylindrical implants in terms of quality of osseointegration and maintenance of crestal bone height. Conclusion: It has been gathered from the study that while delayed placement suggests waiting time period varying between 3 and 6 months, it offers a predictable procedure in terms of visibility, good implant-bone contact, and closure all of which, promote a better outcome for dental implant therapy. Immediate implant placement solution is very viable in reducing the time period involved in dental implant therapy. Apart from few to minimum contraindications, it can be predictably performed.\",\"PeriodicalId\":18827,\"journal\":{\"name\":\"National Journal of Maxillofacial Surgery\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"National Journal of Maxillofacial Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/njms.njms_65_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"National Journal of Maxillofacial Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/njms.njms_65_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A comparative study on efficacy of immediate and delayed placement of cylindrical and tapered dental implants: A clinical prospective study
Introduction: The study deals with improving the understanding of implant design in various situations. Materials and Method: 40 implants were placed out of which 20 were tapered and rest were cylindrical. These were further divided into immediate and delayed settings. The patients were followed upto 6 months and the results were compiled. Result: Statistically significant difference were found between tapered and cylindrical implants in terms of quality of osseointegration and maintenance of crestal bone height. Conclusion: It has been gathered from the study that while delayed placement suggests waiting time period varying between 3 and 6 months, it offers a predictable procedure in terms of visibility, good implant-bone contact, and closure all of which, promote a better outcome for dental implant therapy. Immediate implant placement solution is very viable in reducing the time period involved in dental implant therapy. Apart from few to minimum contraindications, it can be predictably performed.