{"title":"铜金属-有机骨架修饰纳米碳纤维在三维电化学传感器中检测尼鲁胺的信号放大研究","authors":"Elaiyappillai Elanthamilan, Sea-Fue Wang","doi":"10.3390/chemosensors11100544","DOIUrl":null,"url":null,"abstract":"The extensive use of antibiotics has rapidly spread antibiotic resistance, which poses significant health risks to humans. Unfortunately, despite this pressing issue, there is still a lack of a reliable on-site detection method for the residues of antibiotics, such as nilutamide (Nlu). Consequently, there is an urgent need to develop and perfect such a detection method to effectively monitor and control antibiotic residues. In this study, the hydrothermal development of copper-metal-organic framework (Cu-MOF) polyhedrons on the functionalized carbon nanofiber (f-CNF) matrix allowed for the detection of Nlu in biological liquids via a sensitive amperometry technique. Further electrochemical detection of Nlu took place with the cyclic voltammetry (CV) technique Cu-MOF/f-CNF. Analytical and spectroscopic approaches were used to confirm the successful synthesis of Cu-MOF/f-CNF. The prepared material was decorated on the surface of GCE and performed as an electrochemical Nlu sensor, with a broad linear range of 0.01 to 141.4 μM and 2 nM as a lower limit of detection. In addition, the composites had a large surface area and many dedicated sites, which improved electrocatalysis. In practical applications, Cu-MOF/f-CNF/GCE provides a novel strategy for improving electrochemical activity by measuring Nlu concentrations in biological samples.","PeriodicalId":10057,"journal":{"name":"Chemosensors","volume":"19 1","pages":"0"},"PeriodicalIF":3.7000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Signal Amplification for Detection of Nilutamide in Three-Dimensional Electrochemical Sensor Using Copper Metal–Organic Framework Decorated Carbon Nanofibers\",\"authors\":\"Elaiyappillai Elanthamilan, Sea-Fue Wang\",\"doi\":\"10.3390/chemosensors11100544\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The extensive use of antibiotics has rapidly spread antibiotic resistance, which poses significant health risks to humans. Unfortunately, despite this pressing issue, there is still a lack of a reliable on-site detection method for the residues of antibiotics, such as nilutamide (Nlu). Consequently, there is an urgent need to develop and perfect such a detection method to effectively monitor and control antibiotic residues. In this study, the hydrothermal development of copper-metal-organic framework (Cu-MOF) polyhedrons on the functionalized carbon nanofiber (f-CNF) matrix allowed for the detection of Nlu in biological liquids via a sensitive amperometry technique. Further electrochemical detection of Nlu took place with the cyclic voltammetry (CV) technique Cu-MOF/f-CNF. Analytical and spectroscopic approaches were used to confirm the successful synthesis of Cu-MOF/f-CNF. The prepared material was decorated on the surface of GCE and performed as an electrochemical Nlu sensor, with a broad linear range of 0.01 to 141.4 μM and 2 nM as a lower limit of detection. In addition, the composites had a large surface area and many dedicated sites, which improved electrocatalysis. In practical applications, Cu-MOF/f-CNF/GCE provides a novel strategy for improving electrochemical activity by measuring Nlu concentrations in biological samples.\",\"PeriodicalId\":10057,\"journal\":{\"name\":\"Chemosensors\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemosensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/chemosensors11100544\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemosensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/chemosensors11100544","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Signal Amplification for Detection of Nilutamide in Three-Dimensional Electrochemical Sensor Using Copper Metal–Organic Framework Decorated Carbon Nanofibers
The extensive use of antibiotics has rapidly spread antibiotic resistance, which poses significant health risks to humans. Unfortunately, despite this pressing issue, there is still a lack of a reliable on-site detection method for the residues of antibiotics, such as nilutamide (Nlu). Consequently, there is an urgent need to develop and perfect such a detection method to effectively monitor and control antibiotic residues. In this study, the hydrothermal development of copper-metal-organic framework (Cu-MOF) polyhedrons on the functionalized carbon nanofiber (f-CNF) matrix allowed for the detection of Nlu in biological liquids via a sensitive amperometry technique. Further electrochemical detection of Nlu took place with the cyclic voltammetry (CV) technique Cu-MOF/f-CNF. Analytical and spectroscopic approaches were used to confirm the successful synthesis of Cu-MOF/f-CNF. The prepared material was decorated on the surface of GCE and performed as an electrochemical Nlu sensor, with a broad linear range of 0.01 to 141.4 μM and 2 nM as a lower limit of detection. In addition, the composites had a large surface area and many dedicated sites, which improved electrocatalysis. In practical applications, Cu-MOF/f-CNF/GCE provides a novel strategy for improving electrochemical activity by measuring Nlu concentrations in biological samples.
期刊介绍:
Chemosensors (ISSN 2227-9040; CODEN: CHEMO9) is an international, scientific, open access journal on the science and technology of chemical sensors published quarterly online by MDPI.The journal is indexed in Scopus, SCIE (Web of Science), CAPlus / SciFinder, Inspec, Engineering Village and other databases.