{"title":"人工髋关节置入术后股骨近端微观结构行为分析","authors":"Seung-Hun Ryu, Jung-Jin Kim","doi":"10.7736/jkspe.023.054","DOIUrl":null,"url":null,"abstract":"Total hip replacement is a representative treatment for avascular necrosis of the femoral head. However, the stress shielding caused by the replacement induces dissociation of the artificial hip joint and various complications. Many studies have tried to explore the stress shielding but, most studies have been conducted at macro level and not at micro level. Thus, this study aimed to quantitatively analyze the structural behavior of the proximal femur according to total hip replacement at the micro level to explore the stress shielding. For this purpose, this study selected the artificial hip joint of the single wedge type and implanted the joint into a proximal femur that has a high resolution of 50 μm. Then the structural behavior of the implanted femur was analyzed by comparing that of the intact femur under three daily activity loads. As a result, the high possibility was confirmed that the stress shielding will occur in both cortical and cancellous bones under the one-legged stance movements. Additionally, it was discovered that the cancellous bone had a considerably lesser chance of adducting at an angle similar to the neck shaft angle of an artificial hip joint.","PeriodicalId":37663,"journal":{"name":"Journal of the Korean Society for Precision Engineering","volume":"71 9","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Structural Behavior Analysis of the Proximal Femur after Artificial Hip Joint Implantation at Micro Level\",\"authors\":\"Seung-Hun Ryu, Jung-Jin Kim\",\"doi\":\"10.7736/jkspe.023.054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Total hip replacement is a representative treatment for avascular necrosis of the femoral head. However, the stress shielding caused by the replacement induces dissociation of the artificial hip joint and various complications. Many studies have tried to explore the stress shielding but, most studies have been conducted at macro level and not at micro level. Thus, this study aimed to quantitatively analyze the structural behavior of the proximal femur according to total hip replacement at the micro level to explore the stress shielding. For this purpose, this study selected the artificial hip joint of the single wedge type and implanted the joint into a proximal femur that has a high resolution of 50 μm. Then the structural behavior of the implanted femur was analyzed by comparing that of the intact femur under three daily activity loads. As a result, the high possibility was confirmed that the stress shielding will occur in both cortical and cancellous bones under the one-legged stance movements. Additionally, it was discovered that the cancellous bone had a considerably lesser chance of adducting at an angle similar to the neck shaft angle of an artificial hip joint.\",\"PeriodicalId\":37663,\"journal\":{\"name\":\"Journal of the Korean Society for Precision Engineering\",\"volume\":\"71 9\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Korean Society for Precision Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7736/jkspe.023.054\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Society for Precision Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7736/jkspe.023.054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
Structural Behavior Analysis of the Proximal Femur after Artificial Hip Joint Implantation at Micro Level
Total hip replacement is a representative treatment for avascular necrosis of the femoral head. However, the stress shielding caused by the replacement induces dissociation of the artificial hip joint and various complications. Many studies have tried to explore the stress shielding but, most studies have been conducted at macro level and not at micro level. Thus, this study aimed to quantitatively analyze the structural behavior of the proximal femur according to total hip replacement at the micro level to explore the stress shielding. For this purpose, this study selected the artificial hip joint of the single wedge type and implanted the joint into a proximal femur that has a high resolution of 50 μm. Then the structural behavior of the implanted femur was analyzed by comparing that of the intact femur under three daily activity loads. As a result, the high possibility was confirmed that the stress shielding will occur in both cortical and cancellous bones under the one-legged stance movements. Additionally, it was discovered that the cancellous bone had a considerably lesser chance of adducting at an angle similar to the neck shaft angle of an artificial hip joint.
期刊介绍:
Journal of the Korean Society for Precision Engineering (JKSPE) is devoted to publishing original research articles with high ethical standard on all aspects of precision engineering and manufacturing. Specifically, the journal focuses on articles related to improving the precision of machines and manufacturing processes through implementation of creative solutions that stem from advanced research using novel experimental methods, predictive modeling techniques, and rigorous analyses based on mechanical engineering or multidisciplinary approach. The expected outcomes of the knowledge disseminated from JKSPE are enhanced reliability, better motion precision, higher measurement accuracy, and sufficient reliability of precision systems. The various topics covered by JKSPE include: Precision Manufacturing processes, Precision Measurements, Robotics and Automation / Control, Smart Manufacturing System, Design and Materials, Machine Tools, Nano/Micro Technology, Biomechanical Engineering, Additive Manufacturing System, Green Manufacturing Technology.