缓解电动汽车充电对印度住宅建筑能源之星评级的影响

IF 2.9 4区 环境科学与生态学 Q3 ENERGY & FUELS Clean Energy Pub Date : 2023-09-13 DOI:10.1093/ce/zkad041
Rakesh Dalal, Devender Kumar Saini
{"title":"缓解电动汽车充电对印度住宅建筑能源之星评级的影响","authors":"Rakesh Dalal, Devender Kumar Saini","doi":"10.1093/ce/zkad041","DOIUrl":null,"url":null,"abstract":"Abstract The star-labelling programme for residential buildings was introduced by India in 2020 and applies to all residential buildings with no lower limit on the built-up area or electrical demand. The energy-star label for a residential building is awarded against the notified standard by the regulatory body and electric vehicles (EVs) have not been accommodated as a load for residential buildings. The energy consumption of an existing residential building is taken from a study already carried out and compared with the requirement of the Indian residential star-labelling programme with an EV as a plugged-in load. An annual energy gap of 6060 kWh for the existing residential buildings considered in this study for five-star building energy labels increases to 7784 kWh if the EV load is added to the building load. The residential building will lose two energy stars if it caters to the EV load and, to bridge this energy gap, the replacement of existing electrical appliances with five-star-rated energy appliances, employing grid-connected rooftop solar photovoltaics (PV) and retrofit of the building envelope are considered. The techno-economic potential of rooftop solar PV and building envelope retrofitting for existing residential buildings is explored using RETScreen® and eQUEST software, respectively. The study establishes that the installation of rooftop solar PV can accommodate the additional load of EVs and can bridge half and three-quarters of the energy gap to achieve five energy stars for an existing building with and without EVs, respectively. It is the most economical option among the options explored in this study. The target Energy Performance Index is achievable by high-end energy consumers (12 000 kWh/year) by additional measures, the replacement of inefficient electrical appliances and building envelope retrofitting in addition to the installation of rooftop solar PV.","PeriodicalId":36703,"journal":{"name":"Clean Energy","volume":"32 1","pages":"0"},"PeriodicalIF":2.9000,"publicationDate":"2023-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mitigation of the impacts of electric vehicle charging on energy-star ratings for residential buildings in India\",\"authors\":\"Rakesh Dalal, Devender Kumar Saini\",\"doi\":\"10.1093/ce/zkad041\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The star-labelling programme for residential buildings was introduced by India in 2020 and applies to all residential buildings with no lower limit on the built-up area or electrical demand. The energy-star label for a residential building is awarded against the notified standard by the regulatory body and electric vehicles (EVs) have not been accommodated as a load for residential buildings. The energy consumption of an existing residential building is taken from a study already carried out and compared with the requirement of the Indian residential star-labelling programme with an EV as a plugged-in load. An annual energy gap of 6060 kWh for the existing residential buildings considered in this study for five-star building energy labels increases to 7784 kWh if the EV load is added to the building load. The residential building will lose two energy stars if it caters to the EV load and, to bridge this energy gap, the replacement of existing electrical appliances with five-star-rated energy appliances, employing grid-connected rooftop solar photovoltaics (PV) and retrofit of the building envelope are considered. The techno-economic potential of rooftop solar PV and building envelope retrofitting for existing residential buildings is explored using RETScreen® and eQUEST software, respectively. The study establishes that the installation of rooftop solar PV can accommodate the additional load of EVs and can bridge half and three-quarters of the energy gap to achieve five energy stars for an existing building with and without EVs, respectively. It is the most economical option among the options explored in this study. The target Energy Performance Index is achievable by high-end energy consumers (12 000 kWh/year) by additional measures, the replacement of inefficient electrical appliances and building envelope retrofitting in addition to the installation of rooftop solar PV.\",\"PeriodicalId\":36703,\"journal\":{\"name\":\"Clean Energy\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2023-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clean Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/ce/zkad041\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clean Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ce/zkad041","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

印度于2020年推出住宅建筑星级标签计划,适用于所有住宅建筑,没有建筑面积或电力需求的下限。住宅建筑的能源之星标签是根据监管机构的公告标准颁发的,而住宅建筑没有容纳电动汽车作为负荷。现有住宅建筑的能源消耗取自一项已经进行的研究,并与印度住宅星级标签计划的要求进行了比较,其中电动汽车作为插入式负载。如果将电动汽车负荷加入建筑负荷中,本研究考虑的现有住宅建筑五星级建筑能源标签的年能源缺口为6060千瓦时,则增加到7784千瓦时。如果住宅楼满足电动汽车负荷,将失去两颗能源之星。为了弥补这一能源差距,考虑将现有电器更换为五星级能源电器,采用并网屋顶太阳能光伏发电(PV)和改造建筑围护结构。利用RETScreen®和eQUEST软件分别探讨了现有住宅屋顶太阳能光伏和建筑围护结构改造的技术经济潜力。该研究表明,安装屋顶太阳能光伏可以容纳电动汽车的额外负荷,可以弥合一半和四分之三的能源缺口,分别为有电动汽车和没有电动汽车的现有建筑达到五星级能源。这是本研究探索的方案中最经济的方案。高端能源消费者可透过额外措施、更换效率低下的电器及加装楼宇围护结构,以及安装屋顶太阳能光伏装置,达到能源表现指数的目标(每年12 000千瓦时)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mitigation of the impacts of electric vehicle charging on energy-star ratings for residential buildings in India
Abstract The star-labelling programme for residential buildings was introduced by India in 2020 and applies to all residential buildings with no lower limit on the built-up area or electrical demand. The energy-star label for a residential building is awarded against the notified standard by the regulatory body and electric vehicles (EVs) have not been accommodated as a load for residential buildings. The energy consumption of an existing residential building is taken from a study already carried out and compared with the requirement of the Indian residential star-labelling programme with an EV as a plugged-in load. An annual energy gap of 6060 kWh for the existing residential buildings considered in this study for five-star building energy labels increases to 7784 kWh if the EV load is added to the building load. The residential building will lose two energy stars if it caters to the EV load and, to bridge this energy gap, the replacement of existing electrical appliances with five-star-rated energy appliances, employing grid-connected rooftop solar photovoltaics (PV) and retrofit of the building envelope are considered. The techno-economic potential of rooftop solar PV and building envelope retrofitting for existing residential buildings is explored using RETScreen® and eQUEST software, respectively. The study establishes that the installation of rooftop solar PV can accommodate the additional load of EVs and can bridge half and three-quarters of the energy gap to achieve five energy stars for an existing building with and without EVs, respectively. It is the most economical option among the options explored in this study. The target Energy Performance Index is achievable by high-end energy consumers (12 000 kWh/year) by additional measures, the replacement of inefficient electrical appliances and building envelope retrofitting in addition to the installation of rooftop solar PV.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clean Energy
Clean Energy Environmental Science-Management, Monitoring, Policy and Law
CiteScore
4.00
自引率
13.00%
发文量
55
期刊最新文献
Exploring commercial water electrolyser systems: a data-based analysis of product characteristics A hybrid machine-learning model for solar irradiance forecasting An application of a genetic algorithm in co-optimization of geological CO2 storage based on artificial neural networks Optimal design of hybrid renewable-energy microgrid system: a techno–economic–environment–social–reliability perspective A hybrid solar–biogas system for post-COVID-19 rural energy access
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1