Rebeca Menezes Vaz Queiroz Fontes, Tiago Alves de Carvalho Nunes, Ricardo Filipe Santos Machado, Patricia Miranda Leite Ribeiro, Jeidson Antônio Morais Marques, Ana Corte-Real
{"title":"下颌骨形态原型中人类地标识别的可重复性:三维CBCT方法的主要参数","authors":"Rebeca Menezes Vaz Queiroz Fontes, Tiago Alves de Carvalho Nunes, Ricardo Filipe Santos Machado, Patricia Miranda Leite Ribeiro, Jeidson Antônio Morais Marques, Ana Corte-Real","doi":"10.1093/fsr/owad029","DOIUrl":null,"url":null,"abstract":"Abstract The establishment of anthropometric measurements is of fundamental importance for the correct identification of human bodies. The objective of this study was to evaluate the accuracy and reliability of two-dimensional craniometric landmarks obtained from three-dimensional cone beam computed tomography (CBCT) reconstructions for forensic identification of humans. CBCT images with voxel sizes of 0.25, 0.3, and 0.4 mm were obtained using i-CAT® three-dimensional equipment. Ten landmarks were randomly selected, and ten measurements were demarcated in the three-dimensional reconstruction to evaluate the mandibular condyle, ramus, and body. This study demonstrated that protocols with voxels of 0.3 mm should be preferentially indicated for the evaluation of linear and angular measurements. Implementing our methodology using prototypes for clinical and forensic simulations allows comparisons with human databases in identification issues.","PeriodicalId":45852,"journal":{"name":"Forensic Sciences Research","volume":"154 1","pages":"0"},"PeriodicalIF":1.4000,"publicationDate":"2023-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reproducibility of human landmark identification in morphological mandible prototypes: major parameters for a 3D CBCT approach\",\"authors\":\"Rebeca Menezes Vaz Queiroz Fontes, Tiago Alves de Carvalho Nunes, Ricardo Filipe Santos Machado, Patricia Miranda Leite Ribeiro, Jeidson Antônio Morais Marques, Ana Corte-Real\",\"doi\":\"10.1093/fsr/owad029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The establishment of anthropometric measurements is of fundamental importance for the correct identification of human bodies. The objective of this study was to evaluate the accuracy and reliability of two-dimensional craniometric landmarks obtained from three-dimensional cone beam computed tomography (CBCT) reconstructions for forensic identification of humans. CBCT images with voxel sizes of 0.25, 0.3, and 0.4 mm were obtained using i-CAT® three-dimensional equipment. Ten landmarks were randomly selected, and ten measurements were demarcated in the three-dimensional reconstruction to evaluate the mandibular condyle, ramus, and body. This study demonstrated that protocols with voxels of 0.3 mm should be preferentially indicated for the evaluation of linear and angular measurements. Implementing our methodology using prototypes for clinical and forensic simulations allows comparisons with human databases in identification issues.\",\"PeriodicalId\":45852,\"journal\":{\"name\":\"Forensic Sciences Research\",\"volume\":\"154 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Forensic Sciences Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/fsr/owad029\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Sciences Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/fsr/owad029","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
Reproducibility of human landmark identification in morphological mandible prototypes: major parameters for a 3D CBCT approach
Abstract The establishment of anthropometric measurements is of fundamental importance for the correct identification of human bodies. The objective of this study was to evaluate the accuracy and reliability of two-dimensional craniometric landmarks obtained from three-dimensional cone beam computed tomography (CBCT) reconstructions for forensic identification of humans. CBCT images with voxel sizes of 0.25, 0.3, and 0.4 mm were obtained using i-CAT® three-dimensional equipment. Ten landmarks were randomly selected, and ten measurements were demarcated in the three-dimensional reconstruction to evaluate the mandibular condyle, ramus, and body. This study demonstrated that protocols with voxels of 0.3 mm should be preferentially indicated for the evaluation of linear and angular measurements. Implementing our methodology using prototypes for clinical and forensic simulations allows comparisons with human databases in identification issues.