液相色谱-串联质谱法检测肉类中18种新烟碱类杀虫剂及其代谢物的各种商用脱脂吸附剂的评价

IF 1.7 4区 化学 Q3 CHEMISTRY, ANALYTICAL Acta Chromatographica Pub Date : 2023-10-03 DOI:10.1556/1326.2023.01170
Kai Li, Liqiang Guo, Guoning Tian, Xiaojie Xu, Yajing Li
{"title":"液相色谱-串联质谱法检测肉类中18种新烟碱类杀虫剂及其代谢物的各种商用脱脂吸附剂的评价","authors":"Kai Li, Liqiang Guo, Guoning Tian, Xiaojie Xu, Yajing Li","doi":"10.1556/1326.2023.01170","DOIUrl":null,"url":null,"abstract":"Abstract A highly accurate and precise method for the simultaneous detection of 18 neonicotinoids and their metabolites in meat was developed using liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). To improve the pretreatment step of the method, five different commercially available clean-up materials (including C18+PSA (primary secondary amine), Z-Sep (with Discover DSC-C18), EMR-Lipid, SHIMSEN QuEChERS, and Clean-up LPAS) were studied in the treatment of three meat matrices: pork, duck and yellow croaker. Based on the recovery data, we found that among the five purification materials, SHIMSEN QuEChERS was slightly more effective than the others for 18 neonicotinoids. Therefore, SHIMSEN QuEChERS was used as the purification sorbent, and the extraction solvents, extraction methods and chromatographic and mass spectrometric conditions were optimized. A matrix-matched calibration method was applied for quantification. In three different meat matrixes (pork, duck, and yellow croaker), all the target compounds showed good linearity, both with values of r 2 > 0.995. The average recovery of all neonicotinoids ranges from 63.4 to 114.2% (pork), 63.0–113.2% (duck), and 63.9–110.5% (yellow croaker). Relative standard deviations were all <15% for intraday and interday precision. The values of limit of detection (LOD) and limit of quantification (LOQ) were, respectively, ranging from 0.04 to 1.0 μg kg −1 and 0.10 to 2.0 μg kg −1 . Compared with previous reports, this method has advantage in LOQs, indicating that it it may be a preferred choice for the detection of neonicotinoid pesticides in meat samples.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":"87 1","pages":"0"},"PeriodicalIF":1.7000,"publicationDate":"2023-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of various commercial lipid removal sorbents for the detection of 18 neonicotinoid insecticides and their metabolites in meat by liquid chromatography tandem mass spectrometry\",\"authors\":\"Kai Li, Liqiang Guo, Guoning Tian, Xiaojie Xu, Yajing Li\",\"doi\":\"10.1556/1326.2023.01170\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract A highly accurate and precise method for the simultaneous detection of 18 neonicotinoids and their metabolites in meat was developed using liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). To improve the pretreatment step of the method, five different commercially available clean-up materials (including C18+PSA (primary secondary amine), Z-Sep (with Discover DSC-C18), EMR-Lipid, SHIMSEN QuEChERS, and Clean-up LPAS) were studied in the treatment of three meat matrices: pork, duck and yellow croaker. Based on the recovery data, we found that among the five purification materials, SHIMSEN QuEChERS was slightly more effective than the others for 18 neonicotinoids. Therefore, SHIMSEN QuEChERS was used as the purification sorbent, and the extraction solvents, extraction methods and chromatographic and mass spectrometric conditions were optimized. A matrix-matched calibration method was applied for quantification. In three different meat matrixes (pork, duck, and yellow croaker), all the target compounds showed good linearity, both with values of r 2 > 0.995. The average recovery of all neonicotinoids ranges from 63.4 to 114.2% (pork), 63.0–113.2% (duck), and 63.9–110.5% (yellow croaker). Relative standard deviations were all <15% for intraday and interday precision. The values of limit of detection (LOD) and limit of quantification (LOQ) were, respectively, ranging from 0.04 to 1.0 μg kg −1 and 0.10 to 2.0 μg kg −1 . Compared with previous reports, this method has advantage in LOQs, indicating that it it may be a preferred choice for the detection of neonicotinoid pesticides in meat samples.\",\"PeriodicalId\":7130,\"journal\":{\"name\":\"Acta Chromatographica\",\"volume\":\"87 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Chromatographica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1556/1326.2023.01170\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1556/1326.2023.01170","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

建立了一种高效液相色谱-串联质谱(HPLC-MS/MS)同时检测肉类中18种新烟碱类及其代谢物的方法。为了改进该方法的预处理步骤,研究了五种不同的市售清理材料(包括C18+PSA (primary - secondary amine)、Z-Sep (with Discover DSC-C18)、emr -脂质、SHIMSEN QuEChERS和cleanup LPAS)对猪肉、鸭肉和黄鱼三种肉类基质的处理效果。根据回收率数据,我们发现在5种净化材料中,SHIMSEN QuEChERS对18种新烟碱的效果略高于其他材料。因此,采用SHIMSEN QuEChERS作为纯化吸附剂,对提取溶剂、提取方法和色谱质谱条件进行优化。采用矩阵匹配定标法定量。在3种不同的肉类基质(猪肉、鸭肉和黄花鱼)中,所有目标化合物均表现出良好的线性关系,其值均为r2和gt;0.995. 新烟碱类杀虫剂的平均回收率分别为63.4 ~ 114.2%(猪肉)、63.0 ~ 113.2%(鸭)和63.9 ~ 110.5%(黄鱼)。日内和日间精度的相对标准偏差均为<15%。检出限和定量限分别为0.04 ~ 1.0 μg kg - 1和0.10 ~ 2.0 μg kg - 1。与以往报道相比,该方法在定量限上具有优势,可能是肉类样品中新烟碱类农药检测的首选方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of various commercial lipid removal sorbents for the detection of 18 neonicotinoid insecticides and their metabolites in meat by liquid chromatography tandem mass spectrometry
Abstract A highly accurate and precise method for the simultaneous detection of 18 neonicotinoids and their metabolites in meat was developed using liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). To improve the pretreatment step of the method, five different commercially available clean-up materials (including C18+PSA (primary secondary amine), Z-Sep (with Discover DSC-C18), EMR-Lipid, SHIMSEN QuEChERS, and Clean-up LPAS) were studied in the treatment of three meat matrices: pork, duck and yellow croaker. Based on the recovery data, we found that among the five purification materials, SHIMSEN QuEChERS was slightly more effective than the others for 18 neonicotinoids. Therefore, SHIMSEN QuEChERS was used as the purification sorbent, and the extraction solvents, extraction methods and chromatographic and mass spectrometric conditions were optimized. A matrix-matched calibration method was applied for quantification. In three different meat matrixes (pork, duck, and yellow croaker), all the target compounds showed good linearity, both with values of r 2 > 0.995. The average recovery of all neonicotinoids ranges from 63.4 to 114.2% (pork), 63.0–113.2% (duck), and 63.9–110.5% (yellow croaker). Relative standard deviations were all <15% for intraday and interday precision. The values of limit of detection (LOD) and limit of quantification (LOQ) were, respectively, ranging from 0.04 to 1.0 μg kg −1 and 0.10 to 2.0 μg kg −1 . Compared with previous reports, this method has advantage in LOQs, indicating that it it may be a preferred choice for the detection of neonicotinoid pesticides in meat samples.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Chromatographica
Acta Chromatographica 化学-分析化学
CiteScore
4.00
自引率
0.00%
发文量
55
审稿时长
2.3 months
期刊介绍: Acta Chromatographica Open Access Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.
期刊最新文献
A comprehensive assessment of the biological attributes of and analytical quantification methods for monosodium glutamate Evaluation of the RP-LC method for determining the pKa of abiraterone and its assay Development, validation and greenness assessment of environmentally friendly analytical methods for the quantification of lenalidomide in pharmaceutical formulations Green RP-HPLC methods for assay and related substances in rivaroxaban tablets Simultaneous qualitative and quantitative analysis for evaluating constituents of Atractylodis macrocephalae rhizome by UPLC-QTOF-MS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1