{"title":"一种新型低成本、可穿戴式运动监测仪在实验室环境中的有效性","authors":"Jacob Barkley, Andrew Newton, Ellen Glickman","doi":"10.53520/rdhs2023.10469","DOIUrl":null,"url":null,"abstract":"Introduction: Wearable physical activity monitors are popular and may provide a more accurate data than subjective methods. The present study assessed the validity of a novel, low-cost wearable physical activity monitor (Movband 3) relative to established measures. Methods: Participants (N = 19) completed four treadmill stages (1.5, 3.0, 4.0, 6.0 MPH) while wearing the Movband 3 and the validated Actigraph GT1M monitor. Oxygen consumption (VO2 ml/kg/min) and heart rate (beats/min) were recorded. The relationship between Movband data and established measures was assessed via Pearson’s correlations. Tests of agreement were performed for actual and Movband miles traveled. Results: There were large, positive, significant (p < 0.001) effect sizes for the associations between Movband counts and Actigraph counts (r = 0.72), VO2 (r = 0.59), and heart rate (r = 0.63). There was also a large, positive, significant (p < 0.001) association between actual and Movband miles (r = 0.97). However, the difference (Δ) between Movband and actual miles was greater than a null hypothesis of zero (∆ = 0.77 ± 0.45 miles or 31.8%, t = 7.4, p < 0.001). Conclusion: While there was evidence to support the validity of the Movband 3 for the assessment of physical activity intensity this device did not provide an accurate measure of miles traveled.","PeriodicalId":74674,"journal":{"name":"Research Directs in health sciences","volume":"210 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Validity of a Novel Low-Cost, Wearable Physical Activity Monitor in a Laboratory Setting\",\"authors\":\"Jacob Barkley, Andrew Newton, Ellen Glickman\",\"doi\":\"10.53520/rdhs2023.10469\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Wearable physical activity monitors are popular and may provide a more accurate data than subjective methods. The present study assessed the validity of a novel, low-cost wearable physical activity monitor (Movband 3) relative to established measures. Methods: Participants (N = 19) completed four treadmill stages (1.5, 3.0, 4.0, 6.0 MPH) while wearing the Movband 3 and the validated Actigraph GT1M monitor. Oxygen consumption (VO2 ml/kg/min) and heart rate (beats/min) were recorded. The relationship between Movband data and established measures was assessed via Pearson’s correlations. Tests of agreement were performed for actual and Movband miles traveled. Results: There were large, positive, significant (p < 0.001) effect sizes for the associations between Movband counts and Actigraph counts (r = 0.72), VO2 (r = 0.59), and heart rate (r = 0.63). There was also a large, positive, significant (p < 0.001) association between actual and Movband miles (r = 0.97). However, the difference (Δ) between Movband and actual miles was greater than a null hypothesis of zero (∆ = 0.77 ± 0.45 miles or 31.8%, t = 7.4, p < 0.001). Conclusion: While there was evidence to support the validity of the Movband 3 for the assessment of physical activity intensity this device did not provide an accurate measure of miles traveled.\",\"PeriodicalId\":74674,\"journal\":{\"name\":\"Research Directs in health sciences\",\"volume\":\"210 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research Directs in health sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53520/rdhs2023.10469\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research Directs in health sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53520/rdhs2023.10469","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Validity of a Novel Low-Cost, Wearable Physical Activity Monitor in a Laboratory Setting
Introduction: Wearable physical activity monitors are popular and may provide a more accurate data than subjective methods. The present study assessed the validity of a novel, low-cost wearable physical activity monitor (Movband 3) relative to established measures. Methods: Participants (N = 19) completed four treadmill stages (1.5, 3.0, 4.0, 6.0 MPH) while wearing the Movband 3 and the validated Actigraph GT1M monitor. Oxygen consumption (VO2 ml/kg/min) and heart rate (beats/min) were recorded. The relationship between Movband data and established measures was assessed via Pearson’s correlations. Tests of agreement were performed for actual and Movband miles traveled. Results: There were large, positive, significant (p < 0.001) effect sizes for the associations between Movband counts and Actigraph counts (r = 0.72), VO2 (r = 0.59), and heart rate (r = 0.63). There was also a large, positive, significant (p < 0.001) association between actual and Movband miles (r = 0.97). However, the difference (Δ) between Movband and actual miles was greater than a null hypothesis of zero (∆ = 0.77 ± 0.45 miles or 31.8%, t = 7.4, p < 0.001). Conclusion: While there was evidence to support the validity of the Movband 3 for the assessment of physical activity intensity this device did not provide an accurate measure of miles traveled.