带直流断路器的高压直流电网半桥mmc的直流故障穿越控制

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2023-05-01 DOI:10.1541/ieejjia.22006950
Atsushi Chiba, Kenichiro Sano, Yushi Koyama, Kei Sekiguchi, Takahiro Ishiguro, Daichi Suzuki
{"title":"带直流断路器的高压直流电网半桥mmc的直流故障穿越控制","authors":"Atsushi Chiba, Kenichiro Sano, Yushi Koyama, Kei Sekiguchi, Takahiro Ishiguro, Daichi Suzuki","doi":"10.1541/ieejjia.22006950","DOIUrl":null,"url":null,"abstract":"Operation delay of DC circuit breakers causes a voltage sag of several milliseconds in high-voltage DC (HVDC) grids. The DC voltage sag can cause an overcurrent in the DC side of the modular multilevel converter (MMC), resulting in halting the MMC. This study investigates a method to facilitate continuous operation of the half-bridge MMC during a DC voltage sag. The proposed method performs feedback control of the DC current during DC voltage sags by decreasing the DC and AC voltages of the half-bridge MMC. When the method is applied to symmetrical monopole HVDC systems, the MMC can maintain both its DC and AC currents within the rated range during the voltage sag caused by pole-to-ground faults. Simulation results obtained by a three-terminal HVDC grid verify the DC fault ride-through capability of the half-bridge MMC.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DC Fault Ride-Through Control of Half-Bridge MMCs for the HVDC Grid with DC Circuit Breakers\",\"authors\":\"Atsushi Chiba, Kenichiro Sano, Yushi Koyama, Kei Sekiguchi, Takahiro Ishiguro, Daichi Suzuki\",\"doi\":\"10.1541/ieejjia.22006950\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Operation delay of DC circuit breakers causes a voltage sag of several milliseconds in high-voltage DC (HVDC) grids. The DC voltage sag can cause an overcurrent in the DC side of the modular multilevel converter (MMC), resulting in halting the MMC. This study investigates a method to facilitate continuous operation of the half-bridge MMC during a DC voltage sag. The proposed method performs feedback control of the DC current during DC voltage sags by decreasing the DC and AC voltages of the half-bridge MMC. When the method is applied to symmetrical monopole HVDC systems, the MMC can maintain both its DC and AC currents within the rated range during the voltage sag caused by pole-to-ground faults. Simulation results obtained by a three-terminal HVDC grid verify the DC fault ride-through capability of the half-bridge MMC.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1541/ieejjia.22006950\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1541/ieejjia.22006950","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

在高压直流(HVDC)电网中,直流断路器的运行延迟会导致几毫秒的电压凹陷。直流电压凹陷会导致模块化多电平变换器(MMC)直流侧的过流,导致MMC停止工作。本研究探讨了一种在直流电压跌落时使半桥式MMC连续工作的方法。该方法通过降低半桥式MMC的直流和交流电压,在直流电压下降时对直流电流进行反馈控制。将该方法应用于对称单极直流输电系统中,在极地故障引起的电压暂降期间,MMC系统的直流和交流电流均能保持在额定范围内。三端高压直流电网的仿真结果验证了半桥式MMC的直流故障穿越能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
DC Fault Ride-Through Control of Half-Bridge MMCs for the HVDC Grid with DC Circuit Breakers
Operation delay of DC circuit breakers causes a voltage sag of several milliseconds in high-voltage DC (HVDC) grids. The DC voltage sag can cause an overcurrent in the DC side of the modular multilevel converter (MMC), resulting in halting the MMC. This study investigates a method to facilitate continuous operation of the half-bridge MMC during a DC voltage sag. The proposed method performs feedback control of the DC current during DC voltage sags by decreasing the DC and AC voltages of the half-bridge MMC. When the method is applied to symmetrical monopole HVDC systems, the MMC can maintain both its DC and AC currents within the rated range during the voltage sag caused by pole-to-ground faults. Simulation results obtained by a three-terminal HVDC grid verify the DC fault ride-through capability of the half-bridge MMC.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Differential Costs of Raising Grandchildren on Older Mother-Adult Child Relations in Black and White Families. Does Resilience Mediate the Relationship Between Negative Self-Image and Psychological Distress in Middle-Aged and Older Gay and Bisexual Men? Intergenerational Relations and Well-being Among Older Middle Eastern/Arab American Immigrants During the COVID-19 Pandemic. Caregiving Appraisals and Emotional Valence: Moderating Effects of Activity Participation. Heterogeneity of provider preferences for HIV Care Coordination Program features: latent class analysis of a discrete choice experiment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1