Matthew Abulail, Sean P. Cooper, Matthew G Sandberg, Eric Petersen
{"title":"用激波管点火各种润滑油成分","authors":"Matthew Abulail, Sean P. Cooper, Matthew G Sandberg, Eric Petersen","doi":"10.1115/1.4063543","DOIUrl":null,"url":null,"abstract":"Abstract With new restrictions imposed on gas turbine efficiencies and power outputs, lubricating oils are used at higher temperatures and harsher conditions leading to potential, unintended combustion. To establish an understanding of lubricating oil's resistance to combustion, a new spray injector system was utilized in the High-Pressure Shock Tube (HPST) Facility at the TEES Turbomachinery Laboratory at Texas A&M University. Two gas turbine oils (Mobil DTE 732 and Castrol Perfecto X32), a base mineral oil, and a surrogate (n-hexadecane) were tested at postreflected shock conditions at equivalence ratios near 2.5. Castrol Perfecto X32 was also characterized at an equivalence ratio near 1.2. All of the lubricating oils displayed ignition between temperatures of 1152 and 1383 K and near atmospheric pressures. To characterize combustion, two different definitions of ignition delay time (IDT) were considered: sidewall OH* chemiluminescence and sidewall pressure. Both definitions were used to create temperature-dependent correlations for each of the lubricating oils. In general, both definitions provided similar results within the accuracy of the measurements. One trend from the data herein is that the brand-name oils (Mobil DTE 732 and Castrol Perfecto X32) provided ignition delay times that were similar to each other but slightly larger than the corresponding mineral oil and n-hexadecane results. This difference could be attributed to the additives that are present in the brand-name oils.","PeriodicalId":15685,"journal":{"name":"Journal of Engineering for Gas Turbines and Power-transactions of The Asme","volume":"180 S466","pages":"0"},"PeriodicalIF":1.4000,"publicationDate":"2023-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ignition of Various Lubricating Oil Compositions Using a Shock Tube\",\"authors\":\"Matthew Abulail, Sean P. Cooper, Matthew G Sandberg, Eric Petersen\",\"doi\":\"10.1115/1.4063543\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract With new restrictions imposed on gas turbine efficiencies and power outputs, lubricating oils are used at higher temperatures and harsher conditions leading to potential, unintended combustion. To establish an understanding of lubricating oil's resistance to combustion, a new spray injector system was utilized in the High-Pressure Shock Tube (HPST) Facility at the TEES Turbomachinery Laboratory at Texas A&M University. Two gas turbine oils (Mobil DTE 732 and Castrol Perfecto X32), a base mineral oil, and a surrogate (n-hexadecane) were tested at postreflected shock conditions at equivalence ratios near 2.5. Castrol Perfecto X32 was also characterized at an equivalence ratio near 1.2. All of the lubricating oils displayed ignition between temperatures of 1152 and 1383 K and near atmospheric pressures. To characterize combustion, two different definitions of ignition delay time (IDT) were considered: sidewall OH* chemiluminescence and sidewall pressure. Both definitions were used to create temperature-dependent correlations for each of the lubricating oils. In general, both definitions provided similar results within the accuracy of the measurements. One trend from the data herein is that the brand-name oils (Mobil DTE 732 and Castrol Perfecto X32) provided ignition delay times that were similar to each other but slightly larger than the corresponding mineral oil and n-hexadecane results. This difference could be attributed to the additives that are present in the brand-name oils.\",\"PeriodicalId\":15685,\"journal\":{\"name\":\"Journal of Engineering for Gas Turbines and Power-transactions of The Asme\",\"volume\":\"180 S466\",\"pages\":\"0\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Engineering for Gas Turbines and Power-transactions of The Asme\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4063543\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering for Gas Turbines and Power-transactions of The Asme","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4063543","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Ignition of Various Lubricating Oil Compositions Using a Shock Tube
Abstract With new restrictions imposed on gas turbine efficiencies and power outputs, lubricating oils are used at higher temperatures and harsher conditions leading to potential, unintended combustion. To establish an understanding of lubricating oil's resistance to combustion, a new spray injector system was utilized in the High-Pressure Shock Tube (HPST) Facility at the TEES Turbomachinery Laboratory at Texas A&M University. Two gas turbine oils (Mobil DTE 732 and Castrol Perfecto X32), a base mineral oil, and a surrogate (n-hexadecane) were tested at postreflected shock conditions at equivalence ratios near 2.5. Castrol Perfecto X32 was also characterized at an equivalence ratio near 1.2. All of the lubricating oils displayed ignition between temperatures of 1152 and 1383 K and near atmospheric pressures. To characterize combustion, two different definitions of ignition delay time (IDT) were considered: sidewall OH* chemiluminescence and sidewall pressure. Both definitions were used to create temperature-dependent correlations for each of the lubricating oils. In general, both definitions provided similar results within the accuracy of the measurements. One trend from the data herein is that the brand-name oils (Mobil DTE 732 and Castrol Perfecto X32) provided ignition delay times that were similar to each other but slightly larger than the corresponding mineral oil and n-hexadecane results. This difference could be attributed to the additives that are present in the brand-name oils.
期刊介绍:
The ASME Journal of Engineering for Gas Turbines and Power publishes archival-quality papers in the areas of gas and steam turbine technology, nuclear engineering, internal combustion engines, and fossil power generation. It covers a broad spectrum of practical topics of interest to industry. Subject areas covered include: thermodynamics; fluid mechanics; heat transfer; and modeling; propulsion and power generation components and systems; combustion, fuels, and emissions; nuclear reactor systems and components; thermal hydraulics; heat exchangers; nuclear fuel technology and waste management; I. C. engines for marine, rail, and power generation; steam and hydro power generation; advanced cycles for fossil energy generation; pollution control and environmental effects.