双层平板电极和场反转凝胶电泳模块在水平蛋白SDS-PAGE上的改进分离

IF 2.3 Q3 BIOCHEMICAL RESEARCH METHODS Methods and Protocols Pub Date : 2023-11-03 DOI:10.3390/mps6060106
Dong Woo Lim, Tae-Sung Yoon, Kyung Ho Han, Saba Sajjad, Heung-Seon Shin, Sunghyun Kang
{"title":"双层平板电极和场反转凝胶电泳模块在水平蛋白SDS-PAGE上的改进分离","authors":"Dong Woo Lim, Tae-Sung Yoon, Kyung Ho Han, Saba Sajjad, Heung-Seon Shin, Sunghyun Kang","doi":"10.3390/mps6060106","DOIUrl":null,"url":null,"abstract":"The horizontal flatbed electrophoresis method is employed to separate protein samples, providing greater flexibility for various electrophoretic applications and easier sample loading compared to its vertical counterpart. In the currently available equipment setup, cathode and anode electrodes are positioned on top of a gel at each end. Since an electric field enters the gel from the top, its strength gradually weakens from the top to the bottom of the gel. When examining the interior of gels following electrophoretic separation, the uneven electric field causes the protein bands to lie down forward in the direction of migration, leading to an increase in bandwidth. This issue has remained unaddressed for several decades. To address this problem, new clamp-shaped and double-deck electrodes were developed to apply an electric field simultaneously from both the top and bottom of the gel. Both of these new electrodes facilitated the formation of perpendicular protein band shapes and enhanced resolution at a comparable level. Due to their ease of use, double-deck electrodes are recommended. By combining these new electrodes with the field inversion gel electrophoresis (FIGE) technique, the protein bands could be focused and aligned nearly vertically, resulting in the highest level of electrophoretic resolution. Our electrodes are compatible with polyacrylamide gels of varying sizes, buffer systems, and sample well formats. They can be easily manufactured and seamlessly integrated into existing laboratory instruments for practical use.","PeriodicalId":18715,"journal":{"name":"Methods and Protocols","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improved Separation in Horizontal Protein SDS-PAGE with Double-Deck Flat Electrodes and a Field Inversion Gel Electrophoresis Module\",\"authors\":\"Dong Woo Lim, Tae-Sung Yoon, Kyung Ho Han, Saba Sajjad, Heung-Seon Shin, Sunghyun Kang\",\"doi\":\"10.3390/mps6060106\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The horizontal flatbed electrophoresis method is employed to separate protein samples, providing greater flexibility for various electrophoretic applications and easier sample loading compared to its vertical counterpart. In the currently available equipment setup, cathode and anode electrodes are positioned on top of a gel at each end. Since an electric field enters the gel from the top, its strength gradually weakens from the top to the bottom of the gel. When examining the interior of gels following electrophoretic separation, the uneven electric field causes the protein bands to lie down forward in the direction of migration, leading to an increase in bandwidth. This issue has remained unaddressed for several decades. To address this problem, new clamp-shaped and double-deck electrodes were developed to apply an electric field simultaneously from both the top and bottom of the gel. Both of these new electrodes facilitated the formation of perpendicular protein band shapes and enhanced resolution at a comparable level. Due to their ease of use, double-deck electrodes are recommended. By combining these new electrodes with the field inversion gel electrophoresis (FIGE) technique, the protein bands could be focused and aligned nearly vertically, resulting in the highest level of electrophoretic resolution. Our electrodes are compatible with polyacrylamide gels of varying sizes, buffer systems, and sample well formats. They can be easily manufactured and seamlessly integrated into existing laboratory instruments for practical use.\",\"PeriodicalId\":18715,\"journal\":{\"name\":\"Methods and Protocols\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Methods and Protocols\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/mps6060106\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/mps6060106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

水平平板电泳方法用于分离蛋白质样品,与垂直电泳方法相比,它为各种电泳应用提供了更大的灵活性,并且更容易装载样品。在目前可用的设备设置中,阴极和阳极电极分别位于两端的凝胶顶部。由于电场从凝胶的顶部进入,其强度从凝胶的顶部到底部逐渐减弱。在电泳分离后检查凝胶内部时,不均匀的电场导致蛋白质带在迁移方向上向前躺下,导致带宽增加。这个问题几十年来一直没有得到解决。为了解决这个问题,新的钳形和双层电极被开发出来,同时从凝胶的顶部和底部施加电场。这两种新电极都促进了垂直蛋白质带形状的形成,并在相当水平上提高了分辨率。由于其易于使用,建议使用双层电极。通过将这些新电极与场反转凝胶电泳(FIGE)技术相结合,蛋白质条带可以集中并几乎垂直排列,从而获得最高水平的电泳分辨率。我们的电极与不同尺寸的聚丙烯酰胺凝胶、缓冲系统和样品孔格式兼容。它们可以很容易地制造并无缝集成到现有的实验室仪器中以供实际使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improved Separation in Horizontal Protein SDS-PAGE with Double-Deck Flat Electrodes and a Field Inversion Gel Electrophoresis Module
The horizontal flatbed electrophoresis method is employed to separate protein samples, providing greater flexibility for various electrophoretic applications and easier sample loading compared to its vertical counterpart. In the currently available equipment setup, cathode and anode electrodes are positioned on top of a gel at each end. Since an electric field enters the gel from the top, its strength gradually weakens from the top to the bottom of the gel. When examining the interior of gels following electrophoretic separation, the uneven electric field causes the protein bands to lie down forward in the direction of migration, leading to an increase in bandwidth. This issue has remained unaddressed for several decades. To address this problem, new clamp-shaped and double-deck electrodes were developed to apply an electric field simultaneously from both the top and bottom of the gel. Both of these new electrodes facilitated the formation of perpendicular protein band shapes and enhanced resolution at a comparable level. Due to their ease of use, double-deck electrodes are recommended. By combining these new electrodes with the field inversion gel electrophoresis (FIGE) technique, the protein bands could be focused and aligned nearly vertically, resulting in the highest level of electrophoretic resolution. Our electrodes are compatible with polyacrylamide gels of varying sizes, buffer systems, and sample well formats. They can be easily manufactured and seamlessly integrated into existing laboratory instruments for practical use.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Methods and Protocols
Methods and Protocols Biochemistry, Genetics and Molecular Biology-Biochemistry, Genetics and Molecular Biology (miscellaneous)
CiteScore
3.60
自引率
0.00%
发文量
85
审稿时长
8 weeks
期刊最新文献
Parasitological Examination of the Digestive System of Wild Boar from a Practical Point of View-Endoparasitological Sampling under Field Conditions. Full Validation and Application to Clinical Research of a High-Performance Liquid Chromatography Method for the Assessment of Urinary 3-Indoxyl Sulfate in Pediatric Patients with Hematopoietic Stem Cell Transplant. A Mathematical Model of Pressure Ulcer Formation to Facilitate Prevention and Management. Evaluation of an Italian Population-Based Programme for Risk Assessment and Genetic Counselling and Testing for BRCA1/2-Related Hereditary Breast and Ovarian Cancer after 10 Years of Operation: An Observational Study Protocol. The Sri Lanka Mother and Newborn Growth (S-MaNGro) Cohort: Protocol of a Nationwide Prospective Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1