HyFlex CM和TruNatomy旋转文件系统在适度弯曲根管中CBCT的根管运输和定心能力:一项体外研究

Q3 Dentistry Endodontology Pub Date : 2023-01-01 DOI:10.4103/endo.endo_182_22
Pooja D. Atigre, Leena Hiren Jobanputra, Aditya R. Sharma, Savan K. Kashiyani, Jaiprathiksha Venkatasubramaniam Iyer, Pushpa Kumari
{"title":"HyFlex CM和TruNatomy旋转文件系统在适度弯曲根管中CBCT的根管运输和定心能力:一项体外研究","authors":"Pooja D. Atigre, Leena Hiren Jobanputra, Aditya R. Sharma, Savan K. Kashiyani, Jaiprathiksha Venkatasubramaniam Iyer, Pushpa Kumari","doi":"10.4103/endo.endo_182_22","DOIUrl":null,"url":null,"abstract":"ABSTRACT Aim: The objective of this study was to evaluate and compare canal transportation (CT) and centering ability (CA) in the curved canals prepared using HyFlex CM (HCM) and TruNatomy (TN) rotary file systems with the help of cone-beam computed tomography (CBCT). Materials and Methods: Forty extracted single-rooted mandibular premolars with 10°–30° of curvature were selected and divided into two groups. In Group 1, the canals were prepared with HCM files (Coltene Whaledent) and in Group 2 the canals were prepared with TN Prime rotary files (Dentsply Sirona). Pre- and postinstrumentation scans were performed at the same position using CBCT to evaluate CT and CA at three levels 3 mm, 6 mm, and 9 mm from the apex and were compared using CBCT software (On Demand 3D software). Statistical Analysis Used: The two groups were statistically analyzed with Mann–Whitney U -test. Results: There was no significant difference among the tested groups regarding the canal centering ratio ( P > 0.05). At 6- and 9-mm levels, there was no significant difference in CT among the two groups ( P > 0.05). However, at 3 mm from apex, there was a statistically significant difference ( P = 0.006) with TN files exhibiting lesser CT. Conclusion: Both the file systems respected the canal anatomy, although in the apical third, TN files exhibited better results. Hence, this file system can be considered for instrumentation of canals with moderate apical curvatures. In regard to CA, no significant differences were found among the file systems.","PeriodicalId":11607,"journal":{"name":"Endodontology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Canal transportation and centering ability of HyFlex CM and TruNatomy rotary file systems in moderately curved root canals using CBCT: An in vitro study\",\"authors\":\"Pooja D. Atigre, Leena Hiren Jobanputra, Aditya R. Sharma, Savan K. Kashiyani, Jaiprathiksha Venkatasubramaniam Iyer, Pushpa Kumari\",\"doi\":\"10.4103/endo.endo_182_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Aim: The objective of this study was to evaluate and compare canal transportation (CT) and centering ability (CA) in the curved canals prepared using HyFlex CM (HCM) and TruNatomy (TN) rotary file systems with the help of cone-beam computed tomography (CBCT). Materials and Methods: Forty extracted single-rooted mandibular premolars with 10°–30° of curvature were selected and divided into two groups. In Group 1, the canals were prepared with HCM files (Coltene Whaledent) and in Group 2 the canals were prepared with TN Prime rotary files (Dentsply Sirona). Pre- and postinstrumentation scans were performed at the same position using CBCT to evaluate CT and CA at three levels 3 mm, 6 mm, and 9 mm from the apex and were compared using CBCT software (On Demand 3D software). Statistical Analysis Used: The two groups were statistically analyzed with Mann–Whitney U -test. Results: There was no significant difference among the tested groups regarding the canal centering ratio ( P > 0.05). At 6- and 9-mm levels, there was no significant difference in CT among the two groups ( P > 0.05). However, at 3 mm from apex, there was a statistically significant difference ( P = 0.006) with TN files exhibiting lesser CT. Conclusion: Both the file systems respected the canal anatomy, although in the apical third, TN files exhibited better results. Hence, this file system can be considered for instrumentation of canals with moderate apical curvatures. In regard to CA, no significant differences were found among the file systems.\",\"PeriodicalId\":11607,\"journal\":{\"name\":\"Endodontology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Endodontology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/endo.endo_182_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/endo.endo_182_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

摘要目的:本研究的目的是评估和比较HyFlex CM (HCM)和TruNatomy (TN)旋转文件系统在锥形束计算机断层扫描(CBCT)的帮助下制备的弯曲管的管道运输(CT)和对中能力(CA)。材料与方法:选取10°~ 30°曲率的单根下颌前磨牙40颗,分为两组。组1用HCM锉(Coltene Whaledent)制备根管,组2用TN Prime旋转锉(Dentsply Sirona)制备根管。在同一位置使用CBCT进行仪器前和仪器后扫描,以评估距离尖端3mm, 6mm和9mm三个水平的CT和CA,并使用CBCT软件(随需应变3D软件)进行比较。统计学分析方法:两组采用Mann-Whitney U检验进行统计学分析。结果:两组间根管对中率(P >0.05)。在6毫米和9毫米水平,两组CT无显著差异(P >0.05)。然而,在距尖端3mm处,TN锉表现出较小的CT,差异有统计学意义(P = 0.006)。结论:两种文件系统都尊重根管解剖,但在根尖三分之一,TN文件表现出更好的效果。因此,该文件系统可用于中等根尖曲率的根管内固定。关于CA,在文件系统之间没有发现明显的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Canal transportation and centering ability of HyFlex CM and TruNatomy rotary file systems in moderately curved root canals using CBCT: An in vitro study
ABSTRACT Aim: The objective of this study was to evaluate and compare canal transportation (CT) and centering ability (CA) in the curved canals prepared using HyFlex CM (HCM) and TruNatomy (TN) rotary file systems with the help of cone-beam computed tomography (CBCT). Materials and Methods: Forty extracted single-rooted mandibular premolars with 10°–30° of curvature were selected and divided into two groups. In Group 1, the canals were prepared with HCM files (Coltene Whaledent) and in Group 2 the canals were prepared with TN Prime rotary files (Dentsply Sirona). Pre- and postinstrumentation scans were performed at the same position using CBCT to evaluate CT and CA at three levels 3 mm, 6 mm, and 9 mm from the apex and were compared using CBCT software (On Demand 3D software). Statistical Analysis Used: The two groups were statistically analyzed with Mann–Whitney U -test. Results: There was no significant difference among the tested groups regarding the canal centering ratio ( P > 0.05). At 6- and 9-mm levels, there was no significant difference in CT among the two groups ( P > 0.05). However, at 3 mm from apex, there was a statistically significant difference ( P = 0.006) with TN files exhibiting lesser CT. Conclusion: Both the file systems respected the canal anatomy, although in the apical third, TN files exhibited better results. Hence, this file system can be considered for instrumentation of canals with moderate apical curvatures. In regard to CA, no significant differences were found among the file systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Endodontology
Endodontology Medicine-Anatomy
CiteScore
0.60
自引率
0.00%
发文量
0
审稿时长
28 weeks
期刊最新文献
Comparative evaluation of the clinical and radiographic success of regenerative endodontic procedures in immature versus mature permanent incisors with apical periodontitis: A prospective observational study Sealing efficacy of various rubber dam barrier materials used for isolation procedures: A randomized controlled trial Evaluation of fracture resistance of radicular dentin treated with nanochitosan-loaded calcium hydroxide and nanographene-loaded calcium hydroxide, when used as intracanal medicament: An in vitro study Fracture resistance of endodontically treated maxillary premolars using indirect and direct composite onlays: A comparative study Effect of bonding pericervical dentin with reinforcing materials on strength of root-filled mandibular single-canal premolars: An in vitro study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1