不同去污剂对CAD/CAM块体与修复复合材料粘结强度的影响

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Odovtos - International Journal of Dental Sciences Pub Date : 2023-09-25 DOI:10.15517/ijds.2023.56839
Dilan Kopuz, Elif İlgi Sancak, Neslihan Tekçe
{"title":"不同去污剂对CAD/CAM块体与修复复合材料粘结强度的影响","authors":"Dilan Kopuz, Elif İlgi Sancak, Neslihan Tekçe","doi":"10.15517/ijds.2023.56839","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17 ± 3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces.","PeriodicalId":19450,"journal":{"name":"Odovtos - International Journal of Dental Sciences","volume":"22 1","pages":"0"},"PeriodicalIF":0.5000,"publicationDate":"2023-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Different Decontamination Agents on The Bond Strength of CAD/CAM Blocks and Repair Composite Materials\",\"authors\":\"Dilan Kopuz, Elif İlgi Sancak, Neslihan Tekçe\",\"doi\":\"10.15517/ijds.2023.56839\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17 ± 3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces.\",\"PeriodicalId\":19450,\"journal\":{\"name\":\"Odovtos - International Journal of Dental Sciences\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Odovtos - International Journal of Dental Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15517/ijds.2023.56839\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odovtos - International Journal of Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15517/ijds.2023.56839","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是研究不同的去污剂对唾液污染的CAD/CAM块与修复复合材料的结合强度的影响。采用四种不同的CAD/CAM材料:Katana Zirconia UTML光盘、IPS e.max CAD块、Shofu块和Vita Enamic块,制备了280个3 mm厚的样品。每种材料分为7个不同的亚组(N=70)。第一组表面干净。其他组由被人类唾液污染的样本组成:第二组:阴性对照(未清洗);第三组:喷水清洗;第4组:用70%乙醇清洗;第五组:用伊沃克林清洗;第六组:用武士刀清洁剂清洁;第7组:用磷酸清洗。在净化方案之后,树脂复合圆柱体用一层薄的双固化树脂水泥粘合在CAD/CAM表面。样品在37℃蒸馏水中保存24小时。然后进行剪切粘结强度试验(SBS)。记录这些数值,并在显微镜下评估骨折类型。数据分析采用双因素方差分析和Tukey事后检验。总体而言,各去污剂对Katana Zirconia UTML、IPS e.max和Vita Enamic材料的SBS均有改善(p<0.05)。然而,对于Shofu材料,第6组样品的粘结强度值明显高于第2组样品(p=0.026)。磷酸处理组在Katana氧化锆材料中SBS值最高(26.45±9.38 MPa),而磷酸处理组在Shofu材料中SBS值最低(13.17±3.40 MPa)。每种去污剂都提高了复合材料与受污染的CAD/CAM材料的结合强度。如果在粘合之前没有清洗唾液,SBS值可能会下降。所有去污剂均可安全用于氧化锆、二硅酸锂玻璃陶瓷、杂化陶瓷和聚合物渗透陶瓷表面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Different Decontamination Agents on The Bond Strength of CAD/CAM Blocks and Repair Composite Materials
The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17 ± 3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Odovtos - International Journal of Dental Sciences
Odovtos - International Journal of Dental Sciences DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.00
自引率
0.00%
发文量
50
审稿时长
8 weeks
期刊最新文献
Cephalometric Evaluation of the Relationship Between Cervical Vertebral Morphology and Anomalies and the Cranial Base Angle in Different Facial Types and Skeletal Classes Artificial Intelligence in Costa Rican Education Whitening Toothpastes Effect on Enamel Surface Morphology, Chemical Profile and Color: An In Vitro Study Salivary Cytokine Profile in Patients with Oral Lichen Planus Prevalence of Lesions and Oral Mucosal Normal Variations in an Elderly Population in Costa Rica
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1