高折射率响应全介质超表面传感器几何设计优化

IF 3.7 3区 工程技术 Q2 CHEMISTRY, ANALYTICAL Chemosensors Pub Date : 2023-09-11 DOI:10.3390/chemosensors11090498
Chia-Te Chang, Chia-Ming Yang, I-Hsuan Chen, Chih-Ching Ho, Yu-Jen Lu, Chih-Jen Yu
{"title":"高折射率响应全介质超表面传感器几何设计优化","authors":"Chia-Te Chang, Chia-Ming Yang, I-Hsuan Chen, Chih-Ching Ho, Yu-Jen Lu, Chih-Jen Yu","doi":"10.3390/chemosensors11090498","DOIUrl":null,"url":null,"abstract":"This study aims to develop a refractive-index sensor operating in the visible region using an all-dielectric metasurface, which was chosen for its advantages of low optical loss and narrow spectral bandwidth, compared to those of conventional metallic metasurfaces. COMSOL software was utilized as a calculation tool to simulate the resonant properties of an all-dielectric metasurface composed of a circular nanohole-structured titanium oxide (TiO2) thin film, with the aim of enhancing the sensitivity of the refractive index for sensing targets. The simulation focused on finding the best geometrical conditions for the all-dielectric metasurface to achieve high sensitivity. Two resonance modes observed in this metasurface were considered: the quasi-bound-state-in-the-continuum (qBIC) mode and the perfect-reflection (PR) mode. The simulated results demonstrated that high sensitivities of 257 nm/RIU at the PR mode and 94 nm/RIU at the qBIC mode in the visible spectral range could be obtained by periodically constructing the metasurface with a unit cell having a lattice constant of 350 nm, a nanohole radius of 160 nm, and a nanohole depth of 250 nm. Furthermore, the study showed that the resonance mode that enabled high sensitivity was the PR mode, with a sensitivity nearly three times larger than that of the qBIC mode and the ability to reach the highest reflectance at the resonance wavelength. The optimized feature had the highest reflectance at a resonant wavelength of 570.19 nm, and although the quality factor was 25.50, these designed parameters were considered sufficient for developing a refractive index biosensor with high sensitivity and optical efficiency when operating in the visible spectral range.","PeriodicalId":10057,"journal":{"name":"Chemosensors","volume":"11 1","pages":"0"},"PeriodicalIF":3.7000,"publicationDate":"2023-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of the Geometrical Design for an All-Dielectric Metasurface Sensor with a High Refractive-Index Response\",\"authors\":\"Chia-Te Chang, Chia-Ming Yang, I-Hsuan Chen, Chih-Ching Ho, Yu-Jen Lu, Chih-Jen Yu\",\"doi\":\"10.3390/chemosensors11090498\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aims to develop a refractive-index sensor operating in the visible region using an all-dielectric metasurface, which was chosen for its advantages of low optical loss and narrow spectral bandwidth, compared to those of conventional metallic metasurfaces. COMSOL software was utilized as a calculation tool to simulate the resonant properties of an all-dielectric metasurface composed of a circular nanohole-structured titanium oxide (TiO2) thin film, with the aim of enhancing the sensitivity of the refractive index for sensing targets. The simulation focused on finding the best geometrical conditions for the all-dielectric metasurface to achieve high sensitivity. Two resonance modes observed in this metasurface were considered: the quasi-bound-state-in-the-continuum (qBIC) mode and the perfect-reflection (PR) mode. The simulated results demonstrated that high sensitivities of 257 nm/RIU at the PR mode and 94 nm/RIU at the qBIC mode in the visible spectral range could be obtained by periodically constructing the metasurface with a unit cell having a lattice constant of 350 nm, a nanohole radius of 160 nm, and a nanohole depth of 250 nm. Furthermore, the study showed that the resonance mode that enabled high sensitivity was the PR mode, with a sensitivity nearly three times larger than that of the qBIC mode and the ability to reach the highest reflectance at the resonance wavelength. The optimized feature had the highest reflectance at a resonant wavelength of 570.19 nm, and although the quality factor was 25.50, these designed parameters were considered sufficient for developing a refractive index biosensor with high sensitivity and optical efficiency when operating in the visible spectral range.\",\"PeriodicalId\":10057,\"journal\":{\"name\":\"Chemosensors\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemosensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/chemosensors11090498\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemosensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/chemosensors11090498","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

与传统金属超表面相比,选择全介质超表面具有光学损耗低、光谱带宽窄的优点,因此本研究旨在开发一种工作在可见光区的折射率传感器。利用COMSOL软件作为计算工具,模拟由圆形纳米孔结构的氧化钛(TiO2)薄膜组成的全介电超表面的谐振特性,以提高其对传感目标的折射率灵敏度。模拟的重点是寻找实现高灵敏度的全介电超表面的最佳几何条件。考虑了在该超表面上观察到的两种共振模式:准连续界态(qBIC)模式和完美反射(PR)模式。模拟结果表明,采用晶格常数为350 nm、纳米孔半径为160 nm、纳米孔深度为250 nm的晶胞周期性构建超表面,在PR模式下可获得257 nm/RIU的高灵敏度,在qBIC模式下可获得94 nm/RIU的高灵敏度。此外,研究表明,实现高灵敏度的共振模式是PR模式,其灵敏度几乎是qBIC模式的3倍,并且能够在共振波长处达到最高反射率。优化后的特征在570.19 nm的共振波长处具有最高的反射率,虽然质量因子为25.50,但这些设计参数足以在可见光范围内开发出高灵敏度和高光学效率的折射率生物传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization of the Geometrical Design for an All-Dielectric Metasurface Sensor with a High Refractive-Index Response
This study aims to develop a refractive-index sensor operating in the visible region using an all-dielectric metasurface, which was chosen for its advantages of low optical loss and narrow spectral bandwidth, compared to those of conventional metallic metasurfaces. COMSOL software was utilized as a calculation tool to simulate the resonant properties of an all-dielectric metasurface composed of a circular nanohole-structured titanium oxide (TiO2) thin film, with the aim of enhancing the sensitivity of the refractive index for sensing targets. The simulation focused on finding the best geometrical conditions for the all-dielectric metasurface to achieve high sensitivity. Two resonance modes observed in this metasurface were considered: the quasi-bound-state-in-the-continuum (qBIC) mode and the perfect-reflection (PR) mode. The simulated results demonstrated that high sensitivities of 257 nm/RIU at the PR mode and 94 nm/RIU at the qBIC mode in the visible spectral range could be obtained by periodically constructing the metasurface with a unit cell having a lattice constant of 350 nm, a nanohole radius of 160 nm, and a nanohole depth of 250 nm. Furthermore, the study showed that the resonance mode that enabled high sensitivity was the PR mode, with a sensitivity nearly three times larger than that of the qBIC mode and the ability to reach the highest reflectance at the resonance wavelength. The optimized feature had the highest reflectance at a resonant wavelength of 570.19 nm, and although the quality factor was 25.50, these designed parameters were considered sufficient for developing a refractive index biosensor with high sensitivity and optical efficiency when operating in the visible spectral range.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Chemosensors
Chemosensors Chemistry-Analytical Chemistry
CiteScore
5.00
自引率
9.50%
发文量
450
审稿时长
11 weeks
期刊介绍: Chemosensors (ISSN 2227-9040; CODEN: CHEMO9) is an international, scientific, open access journal on the science and technology of chemical sensors published quarterly online by MDPI.The journal is indexed in Scopus, SCIE (Web of Science), CAPlus / SciFinder, Inspec, Engineering Village and other databases.
期刊最新文献
Prostate Cancer Detection in Colombian Patients through E-Senses Devices in Exhaled Breath and Urine Samples Origami Paper-Based Electrochemical Immunosensor with Carbon Nanohorns-Decorated Nanoporous Gold for Zearalenone Detection Spectroscopy and Chemometrics for Conformity Analysis of e-Liquids: Illegal Additive Detection and Nicotine Characterization Nanorods Assembled Hierarchical Bi2S3 for Highly Sensitive Detection of Trace NO2 at Room Temperature Evaluation of the Essential Oil Composition of Five Thymus Species Native to Greece
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1