{"title":"磁制冷系统的热力学分析","authors":"Jong Suk Lee","doi":"10.1007/s44189-023-00040-w","DOIUrl":null,"url":null,"abstract":"Abstract Magnetic refrigeration utilizes the magnetocaloric effect of a magnetic material, whose temperature changes according to the change of magnetic field strength. It is regarded as an eco-friendly refrigeration technology in that it uses magnetic materials as refrigerants instead of CFC, HCFC, and HFC refrigerants used in vapor compression refrigeration. It is also regarded as an energy-efficient refrigeration technology in that it does not use noisy and power-consuming compressors. This paper presents thermodynamic analysis on a magnetic refrigeration system using experimental results obtained from a magnetic refrigeration apparatus. The magnetic refrigeration apparatus was built using two sets of concentric Halbach cylinders consisting of permanent magnet segments. Specifically the coefficient of performance (COP) of the magnetic refrigeration system was calculated using the energy removed from the working fluid across an AMR bed and the work input to run electric motors.","PeriodicalId":13757,"journal":{"name":"International Journal of Air-conditioning and Refrigeration","volume":"32 1","pages":"0"},"PeriodicalIF":0.8000,"publicationDate":"2023-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermodynamic analysis on a magnetic refrigeration system\",\"authors\":\"Jong Suk Lee\",\"doi\":\"10.1007/s44189-023-00040-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Magnetic refrigeration utilizes the magnetocaloric effect of a magnetic material, whose temperature changes according to the change of magnetic field strength. It is regarded as an eco-friendly refrigeration technology in that it uses magnetic materials as refrigerants instead of CFC, HCFC, and HFC refrigerants used in vapor compression refrigeration. It is also regarded as an energy-efficient refrigeration technology in that it does not use noisy and power-consuming compressors. This paper presents thermodynamic analysis on a magnetic refrigeration system using experimental results obtained from a magnetic refrigeration apparatus. The magnetic refrigeration apparatus was built using two sets of concentric Halbach cylinders consisting of permanent magnet segments. Specifically the coefficient of performance (COP) of the magnetic refrigeration system was calculated using the energy removed from the working fluid across an AMR bed and the work input to run electric motors.\",\"PeriodicalId\":13757,\"journal\":{\"name\":\"International Journal of Air-conditioning and Refrigeration\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Air-conditioning and Refrigeration\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s44189-023-00040-w\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"THERMODYNAMICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Air-conditioning and Refrigeration","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s44189-023-00040-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"THERMODYNAMICS","Score":null,"Total":0}
Thermodynamic analysis on a magnetic refrigeration system
Abstract Magnetic refrigeration utilizes the magnetocaloric effect of a magnetic material, whose temperature changes according to the change of magnetic field strength. It is regarded as an eco-friendly refrigeration technology in that it uses magnetic materials as refrigerants instead of CFC, HCFC, and HFC refrigerants used in vapor compression refrigeration. It is also regarded as an energy-efficient refrigeration technology in that it does not use noisy and power-consuming compressors. This paper presents thermodynamic analysis on a magnetic refrigeration system using experimental results obtained from a magnetic refrigeration apparatus. The magnetic refrigeration apparatus was built using two sets of concentric Halbach cylinders consisting of permanent magnet segments. Specifically the coefficient of performance (COP) of the magnetic refrigeration system was calculated using the energy removed from the working fluid across an AMR bed and the work input to run electric motors.
期刊介绍:
As the only international journal in the field of air-conditioning and refrigeration in Asia, IJACR reports researches on the equipments for controlling indoor environment and cooling/refrigeration. It includes broad range of applications and underlying theories including fluid dynamics, thermodynamics, heat transfer, and nano/bio-related technologies. In addition, it covers future energy technologies, such as fuel cell, wind turbine, solar cell/heat, geothermal energy and etc.