方形+皮瓣:一种解除烧伤后瘢痕挛缩的改良方法

IF 1.3 Q3 SURGERY Archives of Plastic Surgery-APS Pub Date : 2023-10-11 DOI:10.1055/a-2189-9767
Mahmoud A. Hifny, Rei Ogawa
{"title":"方形+皮瓣:一种解除烧伤后瘢痕挛缩的改良方法","authors":"Mahmoud A. Hifny, Rei Ogawa","doi":"10.1055/a-2189-9767","DOIUrl":null,"url":null,"abstract":"The square flap method has been successful in releasing contracture bands at various body regions. However, the original square flap method alone may not be efficient in releasing long contracture bands. We, therefore, proposed an extended design to the traditional design, which is called the “square-plus flap”. A 4-year-old girl presented with a post-burn web-like contracture band over the right axilla. We marked a square flap technique at the center of the contracture band and then two additional Z-plasties were placed on both edges of the flap. After the release and securing of the square flap, the adjacent distal z-plasty was then transposed and sutured in their new locations. We do not need to incise the proximal z-plasty as we could achieve complete relaxation of the contracture band. This novel modification can be added to the plastic surgeon’s armamentarium for releasing long post-burn contracture bands involving distinct body regions.","PeriodicalId":47543,"journal":{"name":"Archives of Plastic Surgery-APS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Square-Plus Flap: A Modification to Release Long Post-Burn Scar Contractures\",\"authors\":\"Mahmoud A. Hifny, Rei Ogawa\",\"doi\":\"10.1055/a-2189-9767\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The square flap method has been successful in releasing contracture bands at various body regions. However, the original square flap method alone may not be efficient in releasing long contracture bands. We, therefore, proposed an extended design to the traditional design, which is called the “square-plus flap”. A 4-year-old girl presented with a post-burn web-like contracture band over the right axilla. We marked a square flap technique at the center of the contracture band and then two additional Z-plasties were placed on both edges of the flap. After the release and securing of the square flap, the adjacent distal z-plasty was then transposed and sutured in their new locations. We do not need to incise the proximal z-plasty as we could achieve complete relaxation of the contracture band. This novel modification can be added to the plastic surgeon’s armamentarium for releasing long post-burn contracture bands involving distinct body regions.\",\"PeriodicalId\":47543,\"journal\":{\"name\":\"Archives of Plastic Surgery-APS\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Plastic Surgery-APS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2189-9767\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Plastic Surgery-APS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2189-9767","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

方形皮瓣法已成功地在不同的身体区域释放挛缩带。然而,原始的方形皮瓣方法单独可能不能有效地释放长挛缩带。因此,我们提出了一种传统设计的扩展设计,称为“方正襟翼”。一名四岁女孩在右腋窝出现烧伤后网状挛缩带。我们在挛缩带的中心标记了一个方形皮瓣技术,然后在皮瓣的两边放置了两个额外的z形塑料。在释放和固定方形皮瓣后,将相邻远端z形成形术转置并缝合在其新位置。我们不需要切开近端z形成形术,因为我们可以实现挛缩带的完全松弛。这种新颖的改良可以添加到整形外科医生的器械中,用于释放涉及不同身体区域的烧伤后长挛缩带。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Square-Plus Flap: A Modification to Release Long Post-Burn Scar Contractures
The square flap method has been successful in releasing contracture bands at various body regions. However, the original square flap method alone may not be efficient in releasing long contracture bands. We, therefore, proposed an extended design to the traditional design, which is called the “square-plus flap”. A 4-year-old girl presented with a post-burn web-like contracture band over the right axilla. We marked a square flap technique at the center of the contracture band and then two additional Z-plasties were placed on both edges of the flap. After the release and securing of the square flap, the adjacent distal z-plasty was then transposed and sutured in their new locations. We do not need to incise the proximal z-plasty as we could achieve complete relaxation of the contracture band. This novel modification can be added to the plastic surgeon’s armamentarium for releasing long post-burn contracture bands involving distinct body regions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.10
自引率
6.70%
发文量
131
审稿时长
10 weeks
期刊最新文献
Minilifting: Short-Scar Rhytidectomy with Thread Lifting. The Old and the New-An Ellege. Distally Based Lymphatic Microsurgical Preventive Healing Approach-A Modification of the Classic Approach. Safety and Effectiveness of Liposuction Modalities in Managing Lipedema: Systematic Review and Meta-analysis. "Funducation"-The New Age of Learning, Intersection of Education, and Fun.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1