{"title":"基于成本的大型电力系统电池储能负荷转移实施的经济分析","authors":"Agus Setiawan, Zainal Arifin, Fauzan Hanif Jufri, Budi Sudiarto, Iwa Garniwa, Rudy Setiabudy","doi":"10.1080/14786451.2023.2248503","DOIUrl":null,"url":null,"abstract":"Advances in energy storage technology have allowed the application of load shifting in the utility grid for a more efficient power system operation. However, the economy of the Battery Energy Storage System (BESS) application is not linear to the cost reduction obtained from excluding the costly generators. This paper presents the economic analysis of cost-based load shifting implementation and an approach to determine the generation units to be deactivated and replaced by BESS on three large-scale power grids in Indonesia: Sumbagut, Sumbagteng, and Sumbagsel systems. The economic feasibility is evaluated using the Net Present Value (NPV), considering the savings and the BESS investment cost. The result shows that the proposed approach is more robust than the conventional methods, such as removing the most expensive units, units with the highest cost reduction, units with the best economic return contribution, or the maximum number of units that can be replaced.","PeriodicalId":14406,"journal":{"name":"International Journal of Sustainable Energy","volume":"79 1","pages":"0"},"PeriodicalIF":2.0000,"publicationDate":"2023-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Economic analysis of cost-based load shifting implementation on large utility systems using battery energy storage system\",\"authors\":\"Agus Setiawan, Zainal Arifin, Fauzan Hanif Jufri, Budi Sudiarto, Iwa Garniwa, Rudy Setiabudy\",\"doi\":\"10.1080/14786451.2023.2248503\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Advances in energy storage technology have allowed the application of load shifting in the utility grid for a more efficient power system operation. However, the economy of the Battery Energy Storage System (BESS) application is not linear to the cost reduction obtained from excluding the costly generators. This paper presents the economic analysis of cost-based load shifting implementation and an approach to determine the generation units to be deactivated and replaced by BESS on three large-scale power grids in Indonesia: Sumbagut, Sumbagteng, and Sumbagsel systems. The economic feasibility is evaluated using the Net Present Value (NPV), considering the savings and the BESS investment cost. The result shows that the proposed approach is more robust than the conventional methods, such as removing the most expensive units, units with the highest cost reduction, units with the best economic return contribution, or the maximum number of units that can be replaced.\",\"PeriodicalId\":14406,\"journal\":{\"name\":\"International Journal of Sustainable Energy\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-09-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Sustainable Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/14786451.2023.2248503\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Sustainable Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14786451.2023.2248503","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Economic analysis of cost-based load shifting implementation on large utility systems using battery energy storage system
Advances in energy storage technology have allowed the application of load shifting in the utility grid for a more efficient power system operation. However, the economy of the Battery Energy Storage System (BESS) application is not linear to the cost reduction obtained from excluding the costly generators. This paper presents the economic analysis of cost-based load shifting implementation and an approach to determine the generation units to be deactivated and replaced by BESS on three large-scale power grids in Indonesia: Sumbagut, Sumbagteng, and Sumbagsel systems. The economic feasibility is evaluated using the Net Present Value (NPV), considering the savings and the BESS investment cost. The result shows that the proposed approach is more robust than the conventional methods, such as removing the most expensive units, units with the highest cost reduction, units with the best economic return contribution, or the maximum number of units that can be replaced.
期刊介绍:
Engineering and sustainable development are intrinsically linked. All capital plant and every consumable product depends on an engineering input through design, manufacture and operation, if not for the product itself then for the equipment required to process and transport the raw materials and the final product. Many aspects of sustainable development depend directly on appropriate and timely actions by engineers. Engineering is an extended process of analysis, synthesis, evaluation and execution and, therefore, it is argued that engineers must be involved from the outset of any proposal to develop sustainable solutions. Engineering embraces many disciplines and truly sustainable solutions are usually inter-disciplinary in nature.