{"title":"急诊手术从右心室取出栓塞的房间隔闭塞器-罕见的病例","authors":"SushilKumar Singh, Sarvesh Kumar, Kumar Rahul, Vivek Tewarson, Bhupendra Kumar, Karan Kaushik, Shobhit Kumar","doi":"10.4103/rcm.rcm_32_22","DOIUrl":null,"url":null,"abstract":"Atrial septal defect (ASD) is one of the most common congenital heart defects (3.78/10,000 live births). For several decades, surgical closure has been considered the standard method of repairing an ostium secundum ASD. Surgical treatment is safe and effective, but the complications relate to bleeding, arrhythmia, and residual defects. However, over the years, percutaneous device closure using the Amplatzer ASD occluder (AGA Medical Corp., Golden Valley, Minnesota) has been widely used for the treatment of ASD and has proven to be effective and safe as traditional surgical repair. However, procedure- or device-related complications can occur; Complications commonly associated with ASD closure device includes residual shunt, device malposition or embolization, thrombosis in the vena cava or atrium and erosion of the surrounding tissue which may lead to perforation of the heart, which could be fatal. We report an unusual case of a 16-year-old female with embolization of the ASD occluder device into the right ventricle immediately after device deployment. We removed the device surgically and closed the ASD in a standard manner, with an autologous pericardial patch. The patient was discharged from the hospital without any complications.","PeriodicalId":21031,"journal":{"name":"Research in Cardiovascular Medicine","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Emergent surgical retrieval of an embolized atrial septal occluder device from right ventricle – An unusual occurrence\",\"authors\":\"SushilKumar Singh, Sarvesh Kumar, Kumar Rahul, Vivek Tewarson, Bhupendra Kumar, Karan Kaushik, Shobhit Kumar\",\"doi\":\"10.4103/rcm.rcm_32_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Atrial septal defect (ASD) is one of the most common congenital heart defects (3.78/10,000 live births). For several decades, surgical closure has been considered the standard method of repairing an ostium secundum ASD. Surgical treatment is safe and effective, but the complications relate to bleeding, arrhythmia, and residual defects. However, over the years, percutaneous device closure using the Amplatzer ASD occluder (AGA Medical Corp., Golden Valley, Minnesota) has been widely used for the treatment of ASD and has proven to be effective and safe as traditional surgical repair. However, procedure- or device-related complications can occur; Complications commonly associated with ASD closure device includes residual shunt, device malposition or embolization, thrombosis in the vena cava or atrium and erosion of the surrounding tissue which may lead to perforation of the heart, which could be fatal. We report an unusual case of a 16-year-old female with embolization of the ASD occluder device into the right ventricle immediately after device deployment. We removed the device surgically and closed the ASD in a standard manner, with an autologous pericardial patch. The patient was discharged from the hospital without any complications.\",\"PeriodicalId\":21031,\"journal\":{\"name\":\"Research in Cardiovascular Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research in Cardiovascular Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/rcm.rcm_32_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research in Cardiovascular Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/rcm.rcm_32_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

房间隔缺损(Atrial septal缺损,ASD)是最常见的先天性心脏缺陷之一(3.78/10,000活产)。几十年来,手术闭合一直被认为是修复第二口ASD的标准方法。手术治疗是安全有效的,但并发症涉及出血、心律失常和残留缺陷。然而,多年来,使用Amplatzer ASD闭塞器(AGA Medical Corp., Golden Valley, Minnesota)的经皮装置封闭已被广泛用于治疗ASD,并被证明与传统手术修复一样有效和安全。然而,手术或器械相关的并发症可能发生;与ASD关闭装置相关的常见并发症包括残留分流、装置错位或栓塞、腔静脉或心房血栓形成以及周围组织侵蚀,可能导致心脏穿孔,这可能是致命的。我们报告一个不寻常的情况下,16岁的女性与栓塞ASD闭塞装置进入右心室后立即装置部署。我们通过手术移除该装置,并使用自体心包贴片以标准方式关闭ASD。病人出院了,没有任何并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Emergent surgical retrieval of an embolized atrial septal occluder device from right ventricle – An unusual occurrence
Atrial septal defect (ASD) is one of the most common congenital heart defects (3.78/10,000 live births). For several decades, surgical closure has been considered the standard method of repairing an ostium secundum ASD. Surgical treatment is safe and effective, but the complications relate to bleeding, arrhythmia, and residual defects. However, over the years, percutaneous device closure using the Amplatzer ASD occluder (AGA Medical Corp., Golden Valley, Minnesota) has been widely used for the treatment of ASD and has proven to be effective and safe as traditional surgical repair. However, procedure- or device-related complications can occur; Complications commonly associated with ASD closure device includes residual shunt, device malposition or embolization, thrombosis in the vena cava or atrium and erosion of the surrounding tissue which may lead to perforation of the heart, which could be fatal. We report an unusual case of a 16-year-old female with embolization of the ASD occluder device into the right ventricle immediately after device deployment. We removed the device surgically and closed the ASD in a standard manner, with an autologous pericardial patch. The patient was discharged from the hospital without any complications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Research in Cardiovascular Medicine
Research in Cardiovascular Medicine CARDIAC & CARDIOVASCULAR SYSTEMS-
自引率
0.00%
发文量
13
审稿时长
17 weeks
期刊最新文献
An unusual presentation of a rare case of rhabdomyosarcoma of the left atrium as severe rheumatic mitral stenosis with atrial fibrillation, fast ventricular rate, and left atrial failure Prognostic value of cardiac and noncardiac biomarkers in infective endocarditis: A prospective cross-sectional study Transcatheter closure of the aortopulmonary window with a multifunctional occluder device Predictions of adherence to treatment in patients referred to the heart failure clinic of Shahid Rajaee Hospital in Tehran The association between statin dosage and malignant ventricular arrhythmias in patients with primary prevention implantable cardioverter-defibrillators for ischemic cardiomyopathy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1