{"title":"Amplatzer血管塞II作为异物的双重研究:从心脏到四肢迁移后的检测和定位","authors":"Cassey Noh","doi":"10.1177/15443167221147521","DOIUrl":null,"url":null,"abstract":"This case report illustrates the most unique feature of ultrasound that distinguishes it from other imaging modalities: hemodynamic analysis of blood flow by spectral Doppler waveforms. Duplex evaluation of the patient presented showed the different resulting hemodynamic impacts of the Amplatzer Vascular Plug II (AVP II), an embolic device, as a foreign body in the upper extremity versus the lower extremity: monophasic Doppler waveforms in the upper extremity distal to the location of the AVP II versus multiphasic Doppler waveforms in the comparable lower extremity distal location. This hemodynamic analysis illustrates the different impacts of the migrated AVP II as a foreign body. It is possible that paroxysmal atrial fibrillation could have been a cause of AVP II migration in this case, since there was no surgical manipulation following placement, but that would be a topic for further investigation.","PeriodicalId":52510,"journal":{"name":"Journal for Vascular Ultrasound","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Duplex Studies of Amplatzer Vascular Plug II as a Foreign Body: Detection and Localization Following Migration From the Heart to the Extremities\",\"authors\":\"Cassey Noh\",\"doi\":\"10.1177/15443167221147521\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This case report illustrates the most unique feature of ultrasound that distinguishes it from other imaging modalities: hemodynamic analysis of blood flow by spectral Doppler waveforms. Duplex evaluation of the patient presented showed the different resulting hemodynamic impacts of the Amplatzer Vascular Plug II (AVP II), an embolic device, as a foreign body in the upper extremity versus the lower extremity: monophasic Doppler waveforms in the upper extremity distal to the location of the AVP II versus multiphasic Doppler waveforms in the comparable lower extremity distal location. This hemodynamic analysis illustrates the different impacts of the migrated AVP II as a foreign body. It is possible that paroxysmal atrial fibrillation could have been a cause of AVP II migration in this case, since there was no surgical manipulation following placement, but that would be a topic for further investigation.\",\"PeriodicalId\":52510,\"journal\":{\"name\":\"Journal for Vascular Ultrasound\",\"volume\":\"77 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal for Vascular Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/15443167221147521\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal for Vascular Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15443167221147521","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
Duplex Studies of Amplatzer Vascular Plug II as a Foreign Body: Detection and Localization Following Migration From the Heart to the Extremities
This case report illustrates the most unique feature of ultrasound that distinguishes it from other imaging modalities: hemodynamic analysis of blood flow by spectral Doppler waveforms. Duplex evaluation of the patient presented showed the different resulting hemodynamic impacts of the Amplatzer Vascular Plug II (AVP II), an embolic device, as a foreign body in the upper extremity versus the lower extremity: monophasic Doppler waveforms in the upper extremity distal to the location of the AVP II versus multiphasic Doppler waveforms in the comparable lower extremity distal location. This hemodynamic analysis illustrates the different impacts of the migrated AVP II as a foreign body. It is possible that paroxysmal atrial fibrillation could have been a cause of AVP II migration in this case, since there was no surgical manipulation following placement, but that would be a topic for further investigation.