用Riu方法染色细胞的光镜和扫描电镜结果的比较。

S C Yang
{"title":"用Riu方法染色细胞的光镜和扫描电镜结果的比较。","authors":"S C Yang","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Difficulties with cell recognition are sometimes encountered in surface structural studies of biomedical specimens with scanning electron microscopy (SEM). If cells are stained and examined first by light microscopy (LM), then the specificity of their surface structures when observed by SEM can be reassured. Although other staining methods have been advocated, Riu's stain, which employs eosin yellow, methylene blue and azure I was tested in this study. A total of 28 specimens, including 10 pleural effusions, 4 ascites, 9 peripheral blood cells and 5 bronchial brushings, were collected for comparison. Free cells were fixed with 2% glutaraldehyde and allowed to form sediment on poly-L-lysine precoated plastic cover slips. They were stained with Riu's A and B solutions and observed with a light microscope. A lattice composed of cut lines made by a surgical knife served as the cell finder. Cells of interest were photographed before they were fixed in OsO4, dehydrated and dried in liquid CO2 at a critical-point temperature. Observation with a scanning electron microscope showed that the particular cells could be found within 10 minutes. Cell loss was minimal. Configuration of the cells was preserved and no distortion was detected in their fine surface structure. This study confirms that Riu's stain is suitable for comparative purposes between LM and SEM.</p>","PeriodicalId":22189,"journal":{"name":"Taiwan yi xue hui za zhi. Journal of the Formosan Medical Association","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1989-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison between light and scanning electron microscopic findings in cells stained by Riu's method.\",\"authors\":\"S C Yang\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Difficulties with cell recognition are sometimes encountered in surface structural studies of biomedical specimens with scanning electron microscopy (SEM). If cells are stained and examined first by light microscopy (LM), then the specificity of their surface structures when observed by SEM can be reassured. Although other staining methods have been advocated, Riu's stain, which employs eosin yellow, methylene blue and azure I was tested in this study. A total of 28 specimens, including 10 pleural effusions, 4 ascites, 9 peripheral blood cells and 5 bronchial brushings, were collected for comparison. Free cells were fixed with 2% glutaraldehyde and allowed to form sediment on poly-L-lysine precoated plastic cover slips. They were stained with Riu's A and B solutions and observed with a light microscope. A lattice composed of cut lines made by a surgical knife served as the cell finder. Cells of interest were photographed before they were fixed in OsO4, dehydrated and dried in liquid CO2 at a critical-point temperature. Observation with a scanning electron microscope showed that the particular cells could be found within 10 minutes. Cell loss was minimal. Configuration of the cells was preserved and no distortion was detected in their fine surface structure. This study confirms that Riu's stain is suitable for comparative purposes between LM and SEM.</p>\",\"PeriodicalId\":22189,\"journal\":{\"name\":\"Taiwan yi xue hui za zhi. Journal of the Formosan Medical Association\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Taiwan yi xue hui za zhi. Journal of the Formosan Medical Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Taiwan yi xue hui za zhi. Journal of the Formosan Medical Association","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

用扫描电子显微镜(SEM)研究生物医学标本的表面结构时,有时会遇到细胞识别的困难。如果先用光镜对细胞进行染色和检查,那么用扫描电镜观察细胞表面结构的特异性就可以得到保证。虽然其他染色方法已经被提倡,但在本研究中使用了Riu的染色方法,该染色方法采用了伊红黄、亚甲蓝和天蓝色。共收集28例标本进行比较,其中胸腔积液10例,腹水4例,外周血细胞9例,支气管刷毛5例。游离细胞用2%戊二醛固定,并在聚l -赖氨酸预涂覆的塑料盖片上形成沉积物。用Riu’s A和B溶液染色,光镜下观察。由外科手术刀切割的线组成的格子,用作细胞探测器。在将感兴趣的细胞固定在OsO4中,在临界点温度下在液态二氧化碳中脱水和干燥之前,对其进行拍照。用扫描电子显微镜观察,在10分钟内就能找到特定的细胞。细胞损失最小。细胞的结构被保留,其精细的表面结构没有被检测到变形。本研究证实Riu染色适合于LM和SEM的比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison between light and scanning electron microscopic findings in cells stained by Riu's method.

Difficulties with cell recognition are sometimes encountered in surface structural studies of biomedical specimens with scanning electron microscopy (SEM). If cells are stained and examined first by light microscopy (LM), then the specificity of their surface structures when observed by SEM can be reassured. Although other staining methods have been advocated, Riu's stain, which employs eosin yellow, methylene blue and azure I was tested in this study. A total of 28 specimens, including 10 pleural effusions, 4 ascites, 9 peripheral blood cells and 5 bronchial brushings, were collected for comparison. Free cells were fixed with 2% glutaraldehyde and allowed to form sediment on poly-L-lysine precoated plastic cover slips. They were stained with Riu's A and B solutions and observed with a light microscope. A lattice composed of cut lines made by a surgical knife served as the cell finder. Cells of interest were photographed before they were fixed in OsO4, dehydrated and dried in liquid CO2 at a critical-point temperature. Observation with a scanning electron microscope showed that the particular cells could be found within 10 minutes. Cell loss was minimal. Configuration of the cells was preserved and no distortion was detected in their fine surface structure. This study confirms that Riu's stain is suitable for comparative purposes between LM and SEM.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Rapid spectrophotometric method for quantitation of acetaminophen in serum. Apolipoproteins A-I and B in non-insulin-dependent diabetes mellitus. Postoperative echocardiographic study of patients with symptomatic chronic aortic regurgitation. Cytomegalovirus retinitis treated with ganciclovir in a renal transplant recipient. Anterior pituitary functions in patients with uremia tested by stimulation with four combined hypothalamic releasing hormones.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1