IF 1.7 4区 工程技术 Q3 CONSTRUCTION & BUILDING TECHNOLOGY Science and Technology for the Built Environment Pub Date : 2023-10-26 DOI:10.1080/23744731.2023.2276010
Joshua Rothe, Jerin Robins Ebanesar, Lorenzo Cremaschi
{"title":"LGWP制冷剂R1234ze(E)管束式蒸发器","authors":"Joshua Rothe, Jerin Robins Ebanesar, Lorenzo Cremaschi","doi":"10.1080/23744731.2023.2276010","DOIUrl":null,"url":null,"abstract":"AbstractWith new low-GWP HFO refrigerants, the heat transfer performances and methods for decreasing system refrigerant inventory are receiving increasing interest. In shell-and-tube heat exchangers, refrigerant distribution via pressurized liquid spray has the potential for high heat transfer performance while reducing refrigerant charge. However, no published studies have investigated LGWP refrigerants with spray evaporation on tube bundles. A test apparatus was constructed to measure the shell-side heat transfer coefficients of R1234ze(E) on bundles of tubes with two different enhanced-surface types and in two different bundle geometries at various refrigerant saturation temperatures. The results showed strong dependence on refrigerant properties, tube heat flux, enhanced-surface type, bundle geometry, and refrigerant inlet subcooling. The bundle heat transfer coefficients of R1234ze(E) were similar to that of R134a in the same test setup, usually within ±15% for similar conditions. In both cases, they first increased with the heat flux until a local maximum value was achieved. A localized dryout of the tubes at the bottom of the bundle penalized the overall bundle heat transfer coefficient at very high heat flux. For the condensing surface, bundle heat transfer coefficients rarely exceeded 10 kW/m2-K, whereas values in excess of 30 kW/m2-K were sometimes seen for the evaporating surface.Keywords: LGWP refrigerantsspray evaporationenhanced surfacestube bundlesSubject classification codes: include these here if the journal requires themDisclaimerAs a service to authors and researchers we are providing this version of an accepted manuscript (AM). Copyediting, typesetting, and review of the resulting proofs will be undertaken on this manuscript before final publication of the Version of Record (VoR). During production and pre-press, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal relate to these versions also.","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":"88 2","pages":"0"},"PeriodicalIF":1.7000,"publicationDate":"2023-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tube Bundle Evaporators with LGWP Refrigerant R1234ze(E)\",\"authors\":\"Joshua Rothe, Jerin Robins Ebanesar, Lorenzo Cremaschi\",\"doi\":\"10.1080/23744731.2023.2276010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"AbstractWith new low-GWP HFO refrigerants, the heat transfer performances and methods for decreasing system refrigerant inventory are receiving increasing interest. In shell-and-tube heat exchangers, refrigerant distribution via pressurized liquid spray has the potential for high heat transfer performance while reducing refrigerant charge. However, no published studies have investigated LGWP refrigerants with spray evaporation on tube bundles. A test apparatus was constructed to measure the shell-side heat transfer coefficients of R1234ze(E) on bundles of tubes with two different enhanced-surface types and in two different bundle geometries at various refrigerant saturation temperatures. The results showed strong dependence on refrigerant properties, tube heat flux, enhanced-surface type, bundle geometry, and refrigerant inlet subcooling. The bundle heat transfer coefficients of R1234ze(E) were similar to that of R134a in the same test setup, usually within ±15% for similar conditions. In both cases, they first increased with the heat flux until a local maximum value was achieved. A localized dryout of the tubes at the bottom of the bundle penalized the overall bundle heat transfer coefficient at very high heat flux. For the condensing surface, bundle heat transfer coefficients rarely exceeded 10 kW/m2-K, whereas values in excess of 30 kW/m2-K were sometimes seen for the evaporating surface.Keywords: LGWP refrigerantsspray evaporationenhanced surfacestube bundlesSubject classification codes: include these here if the journal requires themDisclaimerAs a service to authors and researchers we are providing this version of an accepted manuscript (AM). Copyediting, typesetting, and review of the resulting proofs will be undertaken on this manuscript before final publication of the Version of Record (VoR). During production and pre-press, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal relate to these versions also.\",\"PeriodicalId\":21556,\"journal\":{\"name\":\"Science and Technology for the Built Environment\",\"volume\":\"88 2\",\"pages\":\"0\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-10-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Science and Technology for the Built Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/23744731.2023.2276010\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science and Technology for the Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/23744731.2023.2276010","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

摘要随着新型低gwp HFO制冷剂的出现,系统制冷剂的传热性能和减少系统制冷剂库存的方法受到越来越多的关注。在管壳式换热器中,制冷剂通过加压液体喷雾分布,在减少制冷剂充注量的同时具有较高的传热性能。然而,目前还没有发表的关于液冷潜能值制冷剂在管束上喷雾蒸发的研究。搭建了R1234ze(E)在不同制冷剂饱和温度下两种不同强化表面类型和两种不同管束几何形状的管束上的壳侧换热系数测试装置。结果表明,制冷剂性能、管热流密度、强化表面类型、束状几何形状和制冷剂进口过冷程度都有很强的依赖性。在相同的试验装置下,R1234ze(E)的束传热系数与R134a相似,在相同的条件下通常在±15%以内。在这两种情况下,它们首先随热通量增加,直到达到局部最大值。在非常高的热流密度下,管束底部的管的局部干燥对整个管束的传热系数不利。对于冷凝面,束传热系数很少超过10 kW/m2-K,而蒸发面有时会超过30 kW/m2-K。关键词:LGWP制冷剂;喷雾蒸发;增强表面;管束;主题分类代码:如果期刊需要,在这里包括它们免责声明作为对作者和研究人员的服务,我们提供这个版本的已接受手稿(AM)。在最终出版版本记录(VoR)之前,将对该手稿进行编辑、排版和审查。在制作和印前,可能会发现可能影响内容的错误,所有适用于期刊的法律免责声明也与这些版本有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Tube Bundle Evaporators with LGWP Refrigerant R1234ze(E)
AbstractWith new low-GWP HFO refrigerants, the heat transfer performances and methods for decreasing system refrigerant inventory are receiving increasing interest. In shell-and-tube heat exchangers, refrigerant distribution via pressurized liquid spray has the potential for high heat transfer performance while reducing refrigerant charge. However, no published studies have investigated LGWP refrigerants with spray evaporation on tube bundles. A test apparatus was constructed to measure the shell-side heat transfer coefficients of R1234ze(E) on bundles of tubes with two different enhanced-surface types and in two different bundle geometries at various refrigerant saturation temperatures. The results showed strong dependence on refrigerant properties, tube heat flux, enhanced-surface type, bundle geometry, and refrigerant inlet subcooling. The bundle heat transfer coefficients of R1234ze(E) were similar to that of R134a in the same test setup, usually within ±15% for similar conditions. In both cases, they first increased with the heat flux until a local maximum value was achieved. A localized dryout of the tubes at the bottom of the bundle penalized the overall bundle heat transfer coefficient at very high heat flux. For the condensing surface, bundle heat transfer coefficients rarely exceeded 10 kW/m2-K, whereas values in excess of 30 kW/m2-K were sometimes seen for the evaporating surface.Keywords: LGWP refrigerantsspray evaporationenhanced surfacestube bundlesSubject classification codes: include these here if the journal requires themDisclaimerAs a service to authors and researchers we are providing this version of an accepted manuscript (AM). Copyediting, typesetting, and review of the resulting proofs will be undertaken on this manuscript before final publication of the Version of Record (VoR). During production and pre-press, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal relate to these versions also.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Science and Technology for the Built Environment
Science and Technology for the Built Environment THERMODYNAMICSCONSTRUCTION & BUILDING TECH-CONSTRUCTION & BUILDING TECHNOLOGY
CiteScore
4.30
自引率
5.30%
发文量
78
期刊介绍: Science and Technology for the Built Environment (formerly HVAC&R Research) is ASHRAE’s archival research publication, offering comprehensive reporting of original research in science and technology related to the stationary and mobile built environment, including indoor environmental quality, thermodynamic and energy system dynamics, materials properties, refrigerants, renewable and traditional energy systems and related processes and concepts, integrated built environmental system design approaches and tools, simulation approaches and algorithms, building enclosure assemblies, and systems for minimizing and regulating space heating and cooling modes. The journal features review articles that critically assess existing literature and point out future research directions.
期刊最新文献
Assessing the emissions reduction potential and economic feasibility of small-scale (<100 kWe) combined heat and power systems with thermal storage for multi-family residential applications in the United States Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings Ground heat exchanger design tool with RowWise placement of boreholes Socioeconomic factors influencing residential occupancy trends during and post COVID pandemic Buildings XV Conference Special Issue
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1