Mako®机械臂辅助全髋关节置换术:使用更新的THA软件避免碰撞。

IF 0.8 Q4 SURGERY Surgical technology international Pub Date : 2023-12-15 DOI:10.52198/23.STI.43.OS1719
Robert Marchand, Devin Olsen, Craig Shul, Tyler Edmond, Daniel Hameed, Nate Angerett, Michael A Mont
{"title":"Mako®机械臂辅助全髋关节置换术:使用更新的THA软件避免碰撞。","authors":"Robert Marchand, Devin Olsen, Craig Shul, Tyler Edmond, Daniel Hameed, Nate Angerett, Michael A Mont","doi":"10.52198/23.STI.43.OS1719","DOIUrl":null,"url":null,"abstract":"<p><p>The use of robotic-assisted total hip arthroplasty and three-dimensional computed tomography scan-based templating has become increasingly popular over the last 10 years. However, proper planning and execution are vital to producing optimal patient outcomes. In order to achieve these outcomes, the robotic-assisted system requires training, familiarity, and experience. The goal of this article is to provide clear and condensed examples of preoperative planning, as well as adjustments that one can make to avoid impingement. The surgical technique for robotic-assisted total hip arthroplasty is also briefly discussed. Examples will be given using the latest computed tomography (CT) scan-based robotic platform for osteoarthritic hips, with specific examples of various cases of impingement that might be encountered by the surgeon and how to ultimately avoid this problem when performing the arthroplasty. This article, through case histories, will discuss the various principles and adjustments that can be made to place components in the ideal location based on individual anatomy.</p>","PeriodicalId":22194,"journal":{"name":"Surgical technology international","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mako® Robotic-Arm Assisted Total Hip Arthroplasty: Avoiding Impingement with Updated THA Software.\",\"authors\":\"Robert Marchand, Devin Olsen, Craig Shul, Tyler Edmond, Daniel Hameed, Nate Angerett, Michael A Mont\",\"doi\":\"10.52198/23.STI.43.OS1719\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of robotic-assisted total hip arthroplasty and three-dimensional computed tomography scan-based templating has become increasingly popular over the last 10 years. However, proper planning and execution are vital to producing optimal patient outcomes. In order to achieve these outcomes, the robotic-assisted system requires training, familiarity, and experience. The goal of this article is to provide clear and condensed examples of preoperative planning, as well as adjustments that one can make to avoid impingement. The surgical technique for robotic-assisted total hip arthroplasty is also briefly discussed. Examples will be given using the latest computed tomography (CT) scan-based robotic platform for osteoarthritic hips, with specific examples of various cases of impingement that might be encountered by the surgeon and how to ultimately avoid this problem when performing the arthroplasty. This article, through case histories, will discuss the various principles and adjustments that can be made to place components in the ideal location based on individual anatomy.</p>\",\"PeriodicalId\":22194,\"journal\":{\"name\":\"Surgical technology international\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical technology international\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52198/23.STI.43.OS1719\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical technology international","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52198/23.STI.43.OS1719","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

在过去的十年中,机器人辅助全髋关节置换术和三维计算机断层扫描模板的使用越来越受欢迎。然而,适当的计划和执行对于产生最佳的患者结果至关重要。为了实现这些结果,机器人辅助系统需要训练、熟悉和经验。本文的目的是提供清晰和简明的术前计划的例子,以及一个人可以做出的调整,以避免撞击。本文还简要讨论了机器人辅助全髋关节置换术的手术技术。使用最新的基于计算机断层扫描(CT)的机器人平台治疗髋关节骨关节炎的例子,以及外科医生可能遇到的各种撞击病例的具体例子,以及在进行关节成形术时如何最终避免这一问题。本文将通过病例历史,讨论各种原则和调整,可以根据个人解剖结构将组件放置在理想位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mako® Robotic-Arm Assisted Total Hip Arthroplasty: Avoiding Impingement with Updated THA Software.

The use of robotic-assisted total hip arthroplasty and three-dimensional computed tomography scan-based templating has become increasingly popular over the last 10 years. However, proper planning and execution are vital to producing optimal patient outcomes. In order to achieve these outcomes, the robotic-assisted system requires training, familiarity, and experience. The goal of this article is to provide clear and condensed examples of preoperative planning, as well as adjustments that one can make to avoid impingement. The surgical technique for robotic-assisted total hip arthroplasty is also briefly discussed. Examples will be given using the latest computed tomography (CT) scan-based robotic platform for osteoarthritic hips, with specific examples of various cases of impingement that might be encountered by the surgeon and how to ultimately avoid this problem when performing the arthroplasty. This article, through case histories, will discuss the various principles and adjustments that can be made to place components in the ideal location based on individual anatomy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
141
期刊最新文献
Robotic Assisted Lapendoscopic Single-Site Surgery for Ileal Deep Endometriosis. A Case Report and Review of Literature. Robotic versus Laparoscopic Partial Nephrectomy: A Systematic Review and Meta-Analysis of Randomised Trials. Cardiophrenic Lymph Node Resection Through Abdominal Subxiphoid Approach: Surgical Technique. What Happens to Endometriosis During the Menstrual Cycle? Robotic Total Knee Arthroplasty is Associated with Thinner and Less Constrained Polyethylene Inserts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1