双光子吸收法测定闭经妇女的骨密度。

Y K Soong, J J Hsu, K Y Tzen
{"title":"双光子吸收法测定闭经妇女的骨密度。","authors":"Y K Soong,&nbsp;J J Hsu,&nbsp;K Y Tzen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Bone mineral density (BMD) was measured in 17 patients with gonadal dysgenesis, 21 patients with premature ovarian failure, 14 patients with hyperprolactinemia, 23 patients postoophorectomy and 41 normal healthy women. Each group was divided into two subgroups, on the basis of whether or not they were receiving estrogen replacement therapy. Linear regression analysis showed a significant loss of BMD at a rate of 0.006 g/cm2 per year in the lumbar spine of normal healthy women. The distribution of individual values in each study group was near or within normal confidence limits, except for the group with gonadal dysgenesis. The mean BMD of each group without estrogen replacement therapy was significantly less than that of the control group. There was a significant correlation between the duration of amenorrhea and BMD values in the groups with premature ovarian failure and postoophorectomy. These results indicate that BMD, measured by dual photon absorptiometry, was reduced in amenorrheic patients, especially in patients with gonadal dysgenesis. Estrogen replacement therapy was able to decrease the severity of bone loss, but failed to increase the bone mass. Dual photon absorptiometry (DPA) is a simple, effective, and accurate tool for assessing the severity of osteoporosis and monitoring the effect of therapy.</p>","PeriodicalId":22189,"journal":{"name":"Taiwan yi xue hui za zhi. Journal of the Formosan Medical Association","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of bone mineral density in amenorrheic women with dual photon absorptiometry.\",\"authors\":\"Y K Soong,&nbsp;J J Hsu,&nbsp;K Y Tzen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Bone mineral density (BMD) was measured in 17 patients with gonadal dysgenesis, 21 patients with premature ovarian failure, 14 patients with hyperprolactinemia, 23 patients postoophorectomy and 41 normal healthy women. Each group was divided into two subgroups, on the basis of whether or not they were receiving estrogen replacement therapy. Linear regression analysis showed a significant loss of BMD at a rate of 0.006 g/cm2 per year in the lumbar spine of normal healthy women. The distribution of individual values in each study group was near or within normal confidence limits, except for the group with gonadal dysgenesis. The mean BMD of each group without estrogen replacement therapy was significantly less than that of the control group. There was a significant correlation between the duration of amenorrhea and BMD values in the groups with premature ovarian failure and postoophorectomy. These results indicate that BMD, measured by dual photon absorptiometry, was reduced in amenorrheic patients, especially in patients with gonadal dysgenesis. Estrogen replacement therapy was able to decrease the severity of bone loss, but failed to increase the bone mass. Dual photon absorptiometry (DPA) is a simple, effective, and accurate tool for assessing the severity of osteoporosis and monitoring the effect of therapy.</p>\",\"PeriodicalId\":22189,\"journal\":{\"name\":\"Taiwan yi xue hui za zhi. Journal of the Formosan Medical Association\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Taiwan yi xue hui za zhi. Journal of the Formosan Medical Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Taiwan yi xue hui za zhi. Journal of the Formosan Medical Association","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

测定了17例性腺发育不良患者、21例卵巢早衰患者、14例高泌乳素血症患者、23例卵巢切除术后患者和41例正常健康妇女的骨密度(BMD)。根据是否接受雌激素替代疗法,每组被分为两个亚组。线性回归分析显示,正常健康女性腰椎骨密度以每年0.006 g/cm2的速度显著下降。每个研究组的个体值分布接近或在正常置信限内,性腺发育不良组除外。未进行雌激素替代治疗的各组平均骨密度明显低于对照组。卵巢早衰组和卵巢切除术后组闭经时间与骨密度值有显著相关性。这些结果表明,双光子吸收仪测量的骨密度在闭经患者中降低,特别是在性腺发育不良的患者中。雌激素替代疗法能够减轻骨质流失的严重程度,但不能增加骨量。双光子吸收测定法(DPA)是一种简单、有效、准确的评估骨质疏松严重程度和监测治疗效果的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement of bone mineral density in amenorrheic women with dual photon absorptiometry.

Bone mineral density (BMD) was measured in 17 patients with gonadal dysgenesis, 21 patients with premature ovarian failure, 14 patients with hyperprolactinemia, 23 patients postoophorectomy and 41 normal healthy women. Each group was divided into two subgroups, on the basis of whether or not they were receiving estrogen replacement therapy. Linear regression analysis showed a significant loss of BMD at a rate of 0.006 g/cm2 per year in the lumbar spine of normal healthy women. The distribution of individual values in each study group was near or within normal confidence limits, except for the group with gonadal dysgenesis. The mean BMD of each group without estrogen replacement therapy was significantly less than that of the control group. There was a significant correlation between the duration of amenorrhea and BMD values in the groups with premature ovarian failure and postoophorectomy. These results indicate that BMD, measured by dual photon absorptiometry, was reduced in amenorrheic patients, especially in patients with gonadal dysgenesis. Estrogen replacement therapy was able to decrease the severity of bone loss, but failed to increase the bone mass. Dual photon absorptiometry (DPA) is a simple, effective, and accurate tool for assessing the severity of osteoporosis and monitoring the effect of therapy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Rapid spectrophotometric method for quantitation of acetaminophen in serum. Apolipoproteins A-I and B in non-insulin-dependent diabetes mellitus. Postoperative echocardiographic study of patients with symptomatic chronic aortic regurgitation. Cytomegalovirus retinitis treated with ganciclovir in a renal transplant recipient. Anterior pituitary functions in patients with uremia tested by stimulation with four combined hypothalamic releasing hormones.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1