HER2靶向[68Ga] ga - abi -025示踪剂的优化、自动化和符合cgmp的合成

IF 4.4 Q1 CHEMISTRY, INORGANIC & NUCLEAR EJNMMI Radiopharmacy and Chemistry Pub Date : 2023-11-22 DOI:10.1186/s41181-023-00226-y
Emma Jussing, Mélodie Ferrat, Mohammad M. Moein, Henrik Alfredéen, Tetyana Tegnebratt, Klas Bratteby, Erik Samén, Joachim Feldwisch, Renske Altena, Rimma Axelsson, Thuy A. Tran
{"title":"HER2靶向[68Ga] ga - abi -025示踪剂的优化、自动化和符合cgmp的合成","authors":"Emma Jussing,&nbsp;Mélodie Ferrat,&nbsp;Mohammad M. Moein,&nbsp;Henrik Alfredéen,&nbsp;Tetyana Tegnebratt,&nbsp;Klas Bratteby,&nbsp;Erik Samén,&nbsp;Joachim Feldwisch,&nbsp;Renske Altena,&nbsp;Rimma Axelsson,&nbsp;Thuy A. Tran","doi":"10.1186/s41181-023-00226-y","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The Affibody molecule, ABY-025, has demonstrated utility to detect human epidermal growth factor receptor 2 (HER2) in vivo, either radiolabelled with indium-111 (<sup>111</sup>In) or gallium-68 (<sup>68</sup>Ga). Using the latter, <sup>68</sup>Ga, is preferred due to its use in positron emission tomography with superior resolution and quantifying capabilities in the clinical setting compared to <sup>111</sup>In. For an ongoing phase II study (NCT05619016) evaluating ABY-025 for detecting HER2-low lesions and selection of patients for HER2-targeted treatment, the aim was to optimize an automated and cGMP-compliant radiosynthesis of [<sup>68</sup>Ga]Ga-ABY-025.</p><p>[<sup>68</sup>Ga]Ga-ABY-025 was produced on a synthesis module, Modular-Lab PharmTracer (Eckert &amp; Ziegler), commonly used for <sup>68</sup>Ga-labelings. The radiotracer has previously been radiolabeled on this module, but to streamline the production, the method was optimized. Steps requiring manual interactions to the radiolabeling procedure were minimized including a convenient and automated pre-concentration of the <sup>68</sup>Ga-eluate and a simplified automated final formulation procedure. Every part of the radiopharmaceutical production was carefully developed to gain robustness and to avoid any operator bound variations to the manufacturing. The optimized production method was successfully applied for <sup>68</sup>Ga-labeling of another radiotracer, verifying its versatility as a universal and robust method for radiosynthesis of Affibody-based peptides.</p><h3>Results</h3><p>A simplified and optimized automated cGMP-compliant radiosynthesis method of [<sup>68</sup>Ga]Ga-ABY-025 was developed. With a decay corrected radiochemical yield of 44 ± 2%, a radiochemical purity (RCP) of 98 ± 1%, and with an RCP stability of 98 ± 1% at 2 h after production, the method was found highly reproducible. The production method also showed comparable results when implemented for radiolabeling another similar peptide.</p><h3>Conclusion</h3><p>The improvements made for the radiosynthesis of [<sup>68</sup>Ga]Ga-ABY-025, including introducing a pre-concentration of the <sup>68</sup>Ga-eluate, aimed to utilize the full potential of the <sup>68</sup>Ge/<sup>68</sup>Ga generator radioactivity output, thereby reducing radioactivity wastage. Furthermore, reducing the number of manually performed preparative steps prior to the radiosynthesis, not only minimized the risk of potential human/operator errors but also enhanced the process’ robustness. The successful application of this optimized radiosynthesis method to another similar peptide underscores its versatility, suggesting that our method can be adopted for <sup>68</sup>Ga-labeling radiotracers based on Affibody molecules in general.</p><p><i>Trial registration</i>: NCT, NCT05619016, Registered 7 November 2022, https://clinicaltrials.gov/study/NCT05619016?term=HER2&amp;cond=ABY025&amp;rank=1</p></div>","PeriodicalId":534,"journal":{"name":"EJNMMI Radiopharmacy and Chemistry","volume":null,"pages":null},"PeriodicalIF":4.4000,"publicationDate":"2023-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ejnmmipharmchem.springeropen.com/counter/pdf/10.1186/s41181-023-00226-y","citationCount":"0","resultStr":"{\"title\":\"Optimized, automated and cGMP-compliant synthesis of the HER2 targeting [68Ga]Ga-ABY-025 tracer\",\"authors\":\"Emma Jussing,&nbsp;Mélodie Ferrat,&nbsp;Mohammad M. Moein,&nbsp;Henrik Alfredéen,&nbsp;Tetyana Tegnebratt,&nbsp;Klas Bratteby,&nbsp;Erik Samén,&nbsp;Joachim Feldwisch,&nbsp;Renske Altena,&nbsp;Rimma Axelsson,&nbsp;Thuy A. Tran\",\"doi\":\"10.1186/s41181-023-00226-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>The Affibody molecule, ABY-025, has demonstrated utility to detect human epidermal growth factor receptor 2 (HER2) in vivo, either radiolabelled with indium-111 (<sup>111</sup>In) or gallium-68 (<sup>68</sup>Ga). Using the latter, <sup>68</sup>Ga, is preferred due to its use in positron emission tomography with superior resolution and quantifying capabilities in the clinical setting compared to <sup>111</sup>In. For an ongoing phase II study (NCT05619016) evaluating ABY-025 for detecting HER2-low lesions and selection of patients for HER2-targeted treatment, the aim was to optimize an automated and cGMP-compliant radiosynthesis of [<sup>68</sup>Ga]Ga-ABY-025.</p><p>[<sup>68</sup>Ga]Ga-ABY-025 was produced on a synthesis module, Modular-Lab PharmTracer (Eckert &amp; Ziegler), commonly used for <sup>68</sup>Ga-labelings. The radiotracer has previously been radiolabeled on this module, but to streamline the production, the method was optimized. Steps requiring manual interactions to the radiolabeling procedure were minimized including a convenient and automated pre-concentration of the <sup>68</sup>Ga-eluate and a simplified automated final formulation procedure. Every part of the radiopharmaceutical production was carefully developed to gain robustness and to avoid any operator bound variations to the manufacturing. The optimized production method was successfully applied for <sup>68</sup>Ga-labeling of another radiotracer, verifying its versatility as a universal and robust method for radiosynthesis of Affibody-based peptides.</p><h3>Results</h3><p>A simplified and optimized automated cGMP-compliant radiosynthesis method of [<sup>68</sup>Ga]Ga-ABY-025 was developed. With a decay corrected radiochemical yield of 44 ± 2%, a radiochemical purity (RCP) of 98 ± 1%, and with an RCP stability of 98 ± 1% at 2 h after production, the method was found highly reproducible. The production method also showed comparable results when implemented for radiolabeling another similar peptide.</p><h3>Conclusion</h3><p>The improvements made for the radiosynthesis of [<sup>68</sup>Ga]Ga-ABY-025, including introducing a pre-concentration of the <sup>68</sup>Ga-eluate, aimed to utilize the full potential of the <sup>68</sup>Ge/<sup>68</sup>Ga generator radioactivity output, thereby reducing radioactivity wastage. Furthermore, reducing the number of manually performed preparative steps prior to the radiosynthesis, not only minimized the risk of potential human/operator errors but also enhanced the process’ robustness. The successful application of this optimized radiosynthesis method to another similar peptide underscores its versatility, suggesting that our method can be adopted for <sup>68</sup>Ga-labeling radiotracers based on Affibody molecules in general.</p><p><i>Trial registration</i>: NCT, NCT05619016, Registered 7 November 2022, https://clinicaltrials.gov/study/NCT05619016?term=HER2&amp;cond=ABY025&amp;rank=1</p></div>\",\"PeriodicalId\":534,\"journal\":{\"name\":\"EJNMMI Radiopharmacy and Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2023-11-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ejnmmipharmchem.springeropen.com/counter/pdf/10.1186/s41181-023-00226-y\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EJNMMI Radiopharmacy and Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1186/s41181-023-00226-y\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Radiopharmacy and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s41181-023-00226-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

摘要

背景:粘附体分子ABY-025已被证明在体内检测人表皮生长因子受体2 (HER2),用铟-111 (111In)或镓-68 (68Ga)进行放射性标记。使用后者,68Ga,是首选的,因为它在正电子发射断层扫描中使用,与111In相比,在临床环境中具有更高的分辨率和量化能力。在一项正在进行的II期研究(NCT05619016)中,评估了ABY-025检测her2低病变和选择her2靶向治疗的患者,目的是优化[68Ga]Ga-ABY-025的自动化和符合cgmp的放射合成。[68Ga] ga - abby -025是在合成模块Modular-Lab PharmTracer (Eckert & Ziegler)上生产的,该模块通常用于68Ga标记。放射性示踪剂之前已经在该模块上进行了放射性标记,但为了简化生产,对该方法进行了优化。放射性标记过程中需要手动交互的步骤被最小化,包括68ga洗脱液的方便和自动预浓缩以及简化的自动最终配制程序。放射性药物生产的每个部分都经过精心开发,以获得稳健性,并避免任何操作员约束的制造变化。优化后的生产方法成功应用于另一种放射性示踪剂的68ga标记,验证了其作为一种通用且稳健的放射性合成方法的通用性。结果:建立了一种简化优化的符合cgmp的[68Ga]Ga-ABY-025的自动化放射合成方法。经衰变校正的放射化学产率为44±2%,放射化学纯度(RCP)为98±1%,生产后2 h的RCP稳定性为98±1%,重复性高。生产方法也显示类似的结果,当实施放射性标记另一个类似的肽。结论:对[68Ga]Ga-ABY-025的放射性合成所做的改进,包括引入68Ga洗脱物的预浓缩,旨在充分利用68Ge/68Ga发生器的放射性输出潜力,从而减少放射性浪费。此外,减少放射性合成前手动准备步骤的数量,不仅可以最大限度地降低潜在的人为/操作员错误风险,还可以增强过程的稳健性。这种优化的放射性合成方法成功应用于另一个类似的肽,强调了它的通用性,表明我们的方法可以用于基于固定分子的68ga标记放射性示踪剂。试验注册:NCT, NCT05619016, 2022年11月7日注册,https://clinicaltrials.gov/study/NCT05619016?term=HER2&cond=ABY025&rank=1。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimized, automated and cGMP-compliant synthesis of the HER2 targeting [68Ga]Ga-ABY-025 tracer

Background

The Affibody molecule, ABY-025, has demonstrated utility to detect human epidermal growth factor receptor 2 (HER2) in vivo, either radiolabelled with indium-111 (111In) or gallium-68 (68Ga). Using the latter, 68Ga, is preferred due to its use in positron emission tomography with superior resolution and quantifying capabilities in the clinical setting compared to 111In. For an ongoing phase II study (NCT05619016) evaluating ABY-025 for detecting HER2-low lesions and selection of patients for HER2-targeted treatment, the aim was to optimize an automated and cGMP-compliant radiosynthesis of [68Ga]Ga-ABY-025.

[68Ga]Ga-ABY-025 was produced on a synthesis module, Modular-Lab PharmTracer (Eckert & Ziegler), commonly used for 68Ga-labelings. The radiotracer has previously been radiolabeled on this module, but to streamline the production, the method was optimized. Steps requiring manual interactions to the radiolabeling procedure were minimized including a convenient and automated pre-concentration of the 68Ga-eluate and a simplified automated final formulation procedure. Every part of the radiopharmaceutical production was carefully developed to gain robustness and to avoid any operator bound variations to the manufacturing. The optimized production method was successfully applied for 68Ga-labeling of another radiotracer, verifying its versatility as a universal and robust method for radiosynthesis of Affibody-based peptides.

Results

A simplified and optimized automated cGMP-compliant radiosynthesis method of [68Ga]Ga-ABY-025 was developed. With a decay corrected radiochemical yield of 44 ± 2%, a radiochemical purity (RCP) of 98 ± 1%, and with an RCP stability of 98 ± 1% at 2 h after production, the method was found highly reproducible. The production method also showed comparable results when implemented for radiolabeling another similar peptide.

Conclusion

The improvements made for the radiosynthesis of [68Ga]Ga-ABY-025, including introducing a pre-concentration of the 68Ga-eluate, aimed to utilize the full potential of the 68Ge/68Ga generator radioactivity output, thereby reducing radioactivity wastage. Furthermore, reducing the number of manually performed preparative steps prior to the radiosynthesis, not only minimized the risk of potential human/operator errors but also enhanced the process’ robustness. The successful application of this optimized radiosynthesis method to another similar peptide underscores its versatility, suggesting that our method can be adopted for 68Ga-labeling radiotracers based on Affibody molecules in general.

Trial registration: NCT, NCT05619016, Registered 7 November 2022, https://clinicaltrials.gov/study/NCT05619016?term=HER2&cond=ABY025&rank=1

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
8.70%
发文量
30
审稿时长
5 weeks
期刊最新文献
The development of 177Lu-DOTA-CC-PSMA following a unified "Click Chemistry" protocol of synthesizing metal nuclide-conjugated radiopharmaceuticals. In vitro and in vivo analyses of eFAP: a novel FAP-targeting small molecule for radionuclide theranostics and other oncological interventions. Generic semi-automated radiofluorination strategy for single domain antibodies: [18F]FB-labelled single domain antibodies for PET imaging of fibroblast activation protein-α or folate receptor-α overexpression in cancer. Process validation and preclinical development of a new PET cerebral blood flow tracer [11C]MMP for initial clinical trials. Preclinical evaluation of CXCR4 peptides for targeted radionuclide therapy in glioblastoma
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1