{"title":"布比卡因过量需要多次静脉脂乳治疗:一例报告","authors":"Michael L. Behal ,&nbsp;Reba A. Hodge ,&nbsp;Matthew C. Blackburn","doi":"10.1016/j.jemrpt.2023.100060","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Bupivacaine, an amide local anesthetic, is commonly used in intrathecal pumps (IT) for pain and spasticity disorders. Pump malfunctions place patients at risk of bupivacaine overdose and local anesthetic systemic toxicity (LAST); however, there are limited reports of this in the literature.</p></div><div><h3>Case report</h3><p>A 24-year-old male with an IT bupivacaine/baclofen pump presented with weakness, numbness, dyspnea, and somnolence secondary to IT pump malfunction with an unknown amount of bupivacaine/baclofen extravasation into the subcutaneous space. The patient required intubation and vasopressor support but remained persistently hypotensive and bradycardic despite aggressive dose titration. Needle aspiration was performed to remove 14 mL of extravasated drug mixture. Due to persistent hemodynamic instability, intravenous lipid emulsion (ILE) therapy was initiated with 20 ​% lipid emulsion 1.5 mL/kg bolus followed by a continuous infusion of 0.25 mL/kg/min. The patient became hemodynamically stable following 750mL of ILE therapy and was admitted to the intensive care unit. Five hours after ILE therapy cessation, the patient again became hemodynamically unstable, and ILE was re-initiated with a bolus and continuous infusion. Sustained hemodynamic stability was achieved after an additional 450mL of ILE.</p></div><div><h3>Why should an emergency physician be aware of this?</h3><p>IT pump malfunction involving bupivacaine can lead to severe LAST necessitating ILE therapy. Clinicians should be aware of the potential for drug deposition leading to prolonged or recurrent hemodynamic instability requiring repeated administration of ILE therapy.</p></div>","PeriodicalId":73546,"journal":{"name":"JEM reports","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2773232023000561/pdfft?md5=8db2ee0d9f2cebaa1596f7fbdeb5b23a&pid=1-s2.0-S2773232023000561-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Bupivacaine overdose requiring multiple administrations of intravenous lipid emulsion therapy: A case report\",\"authors\":\"Michael L. Behal ,&nbsp;Reba A. Hodge ,&nbsp;Matthew C. Blackburn\",\"doi\":\"10.1016/j.jemrpt.2023.100060\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Bupivacaine, an amide local anesthetic, is commonly used in intrathecal pumps (IT) for pain and spasticity disorders. Pump malfunctions place patients at risk of bupivacaine overdose and local anesthetic systemic toxicity (LAST); however, there are limited reports of this in the literature.</p></div><div><h3>Case report</h3><p>A 24-year-old male with an IT bupivacaine/baclofen pump presented with weakness, numbness, dyspnea, and somnolence secondary to IT pump malfunction with an unknown amount of bupivacaine/baclofen extravasation into the subcutaneous space. The patient required intubation and vasopressor support but remained persistently hypotensive and bradycardic despite aggressive dose titration. Needle aspiration was performed to remove 14 mL of extravasated drug mixture. Due to persistent hemodynamic instability, intravenous lipid emulsion (ILE) therapy was initiated with 20 ​% lipid emulsion 1.5 mL/kg bolus followed by a continuous infusion of 0.25 mL/kg/min. The patient became hemodynamically stable following 750mL of ILE therapy and was admitted to the intensive care unit. Five hours after ILE therapy cessation, the patient again became hemodynamically unstable, and ILE was re-initiated with a bolus and continuous infusion. Sustained hemodynamic stability was achieved after an additional 450mL of ILE.</p></div><div><h3>Why should an emergency physician be aware of this?</h3><p>IT pump malfunction involving bupivacaine can lead to severe LAST necessitating ILE therapy. Clinicians should be aware of the potential for drug deposition leading to prolonged or recurrent hemodynamic instability requiring repeated administration of ILE therapy.</p></div>\",\"PeriodicalId\":73546,\"journal\":{\"name\":\"JEM reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2773232023000561/pdfft?md5=8db2ee0d9f2cebaa1596f7fbdeb5b23a&pid=1-s2.0-S2773232023000561-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JEM reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2773232023000561\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JEM reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2773232023000561","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景布比卡因是一种酰胺类局部麻醉剂,通常用于鞘内泵(IT)治疗疼痛和痉挛性疾病。泵故障使患者面临布比卡因过量和局部麻醉全身毒性(LAST)的风险;然而,文献中关于这方面的报道有限。病例报告:一名24岁的男性,布比卡因/巴氯芬泵出现虚弱、麻木、呼吸困难和嗜睡,继发于布比卡因/巴氯芬泵故障,并有未知数量的布比卡因/巴氯芬外渗到皮下间隙。患者需要插管和血管加压支持,但尽管积极剂量滴定,仍持续低血压和心动过缓。用针吸法取出14 mL外渗药物混合物。由于持续的血流动力学不稳定,静脉脂质乳(ILE)治疗开始时为20%脂质乳1.5 mL/kg,然后持续输注0.25 mL/kg/min。经750mL ILE治疗后,患者血流动力学稳定,并入住重症监护病房。停止ILE治疗5小时后,患者再次出现血流动力学不稳定,再次开始给药并持续输注ILE。在增加450mL ILE后,实现了持续的血流动力学稳定。急诊医生为什么要意识到这一点?布比卡因引起的IT泵故障可导致严重的LAST,需要ILE治疗。临床医生应该意识到药物沉积可能导致延长或复发性血流动力学不稳定,需要反复给予ILE治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bupivacaine overdose requiring multiple administrations of intravenous lipid emulsion therapy: A case report

Background

Bupivacaine, an amide local anesthetic, is commonly used in intrathecal pumps (IT) for pain and spasticity disorders. Pump malfunctions place patients at risk of bupivacaine overdose and local anesthetic systemic toxicity (LAST); however, there are limited reports of this in the literature.

Case report

A 24-year-old male with an IT bupivacaine/baclofen pump presented with weakness, numbness, dyspnea, and somnolence secondary to IT pump malfunction with an unknown amount of bupivacaine/baclofen extravasation into the subcutaneous space. The patient required intubation and vasopressor support but remained persistently hypotensive and bradycardic despite aggressive dose titration. Needle aspiration was performed to remove 14 mL of extravasated drug mixture. Due to persistent hemodynamic instability, intravenous lipid emulsion (ILE) therapy was initiated with 20 ​% lipid emulsion 1.5 mL/kg bolus followed by a continuous infusion of 0.25 mL/kg/min. The patient became hemodynamically stable following 750mL of ILE therapy and was admitted to the intensive care unit. Five hours after ILE therapy cessation, the patient again became hemodynamically unstable, and ILE was re-initiated with a bolus and continuous infusion. Sustained hemodynamic stability was achieved after an additional 450mL of ILE.

Why should an emergency physician be aware of this?

IT pump malfunction involving bupivacaine can lead to severe LAST necessitating ILE therapy. Clinicians should be aware of the potential for drug deposition leading to prolonged or recurrent hemodynamic instability requiring repeated administration of ILE therapy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JEM reports
JEM reports Emergency Medicine
自引率
0.00%
发文量
0
审稿时长
54 days
期刊最新文献
Ultrasound-guided genicular nerve blocks for acute knee pain in the emergency department: A case series The presentation and diagnostic utility of xanthochromia in current practice Erratum regarding previously published articles Erratum regarding previously published articles Lactate gap - A clinical tool for diagnosing and managing ethylene glycol poisoning
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1