房间隔缺损封堵器联合支架治疗夹层后主动脉瘤1例。

IF 1.2 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS CVIR Endovascular Pub Date : 2023-11-29 DOI:10.1186/s42155-023-00405-7
Qiqi Wang, Haijun Wei, Chunshui He, Yang Liu
{"title":"房间隔缺损封堵器联合支架治疗夹层后主动脉瘤1例。","authors":"Qiqi Wang, Haijun Wei, Chunshui He, Yang Liu","doi":"10.1186/s42155-023-00405-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Although the candy-plug technique has been reported to be useful for the treatment of post-dissection aortic aneurysm, the stent graft needs be to customized to accommodate the size of vascular occluders.</p><p><strong>Case presentation: </strong>We present a case of a persistent false lumen successfully treated with endovascular stent-graft and atrial septal defect occluder in a patient with Stanford Type B dissection. A covered stent graft was implanted into the false cavity through a distal rupture, and an atrial septal defect occluder was inserted into the covered stent to seal of the false cavity. Decreased aneurysmal diameter and false lumen thrombosis were noted by CT scan at 6-month follow-up.</p><p><strong>Conclusions: </strong>Our case showed that combined use of a stent graft and atrial septal defect occluder is safe, technically feasible and effective in sealing of the false lumen in post-dissection aortic aneurysm patients with previously failed false lumen thrombosis.</p>","PeriodicalId":52351,"journal":{"name":"CVIR Endovascular","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2023-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10686903/pdf/","citationCount":"0","resultStr":"{\"title\":\"Atrial septal defect occluder combined with stent graft for the management of post-dissection aortic aneurysm previously treated with unsuccessful coils: a case report.\",\"authors\":\"Qiqi Wang, Haijun Wei, Chunshui He, Yang Liu\",\"doi\":\"10.1186/s42155-023-00405-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Although the candy-plug technique has been reported to be useful for the treatment of post-dissection aortic aneurysm, the stent graft needs be to customized to accommodate the size of vascular occluders.</p><p><strong>Case presentation: </strong>We present a case of a persistent false lumen successfully treated with endovascular stent-graft and atrial septal defect occluder in a patient with Stanford Type B dissection. A covered stent graft was implanted into the false cavity through a distal rupture, and an atrial septal defect occluder was inserted into the covered stent to seal of the false cavity. Decreased aneurysmal diameter and false lumen thrombosis were noted by CT scan at 6-month follow-up.</p><p><strong>Conclusions: </strong>Our case showed that combined use of a stent graft and atrial septal defect occluder is safe, technically feasible and effective in sealing of the false lumen in post-dissection aortic aneurysm patients with previously failed false lumen thrombosis.</p>\",\"PeriodicalId\":52351,\"journal\":{\"name\":\"CVIR Endovascular\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10686903/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CVIR Endovascular\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s42155-023-00405-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CVIR Endovascular","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s42155-023-00405-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:虽然糖塞技术已被报道用于治疗夹层后的主动脉瘤,但支架需要定制以适应血管闭塞器的大小。病例介绍:我们报告一例持续性假腔成功治疗血管内支架移植和房间隔缺损闭塞在患者斯坦福B型夹层。通过远端破裂将带盖支架置入假腔内,将房间隔缺损封堵器置入带盖支架内封闭假腔。随访6个月,CT扫描发现动脉瘤直径减小,假腔血栓形成。结论:我们的病例表明,对于先前假腔血栓形成失败的夹层动脉瘤患者,联合使用支架和房间隔缺损封堵器对假腔的封闭是安全、技术上可行和有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Atrial septal defect occluder combined with stent graft for the management of post-dissection aortic aneurysm previously treated with unsuccessful coils: a case report.

Background: Although the candy-plug technique has been reported to be useful for the treatment of post-dissection aortic aneurysm, the stent graft needs be to customized to accommodate the size of vascular occluders.

Case presentation: We present a case of a persistent false lumen successfully treated with endovascular stent-graft and atrial septal defect occluder in a patient with Stanford Type B dissection. A covered stent graft was implanted into the false cavity through a distal rupture, and an atrial septal defect occluder was inserted into the covered stent to seal of the false cavity. Decreased aneurysmal diameter and false lumen thrombosis were noted by CT scan at 6-month follow-up.

Conclusions: Our case showed that combined use of a stent graft and atrial septal defect occluder is safe, technically feasible and effective in sealing of the false lumen in post-dissection aortic aneurysm patients with previously failed false lumen thrombosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CVIR Endovascular
CVIR Endovascular Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.30
自引率
0.00%
发文量
59
期刊最新文献
Feasibility of an antegrade-retrograde single-sheath inverse technique via vertical puncture in dysfunctional hemodialysis arteriovenous fistula angioplasty. Correction: Interventional solutions for post‑surgical problems: a lymphatic leaks review Carbon dioxide-enhanced angiography for detection of colonic diverticular bleeding and clinical outcomes Investigating the effects of percutaneous endovascular aneurysm repair for abdominal aortic aneurysm on the lumen size of the common femoral artery Transjugular antegrade transvenous obliteration, with and without portal decompression, for management of rectal variceal hemorrhage.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1