Jung Hyun Choi, Myung-Jun Shin, Byeong-Ju Lee, Jae-Hyeong Park
{"title":"肺动脉高压患者6分钟步行试验中运动诱导的去饱和与不良临床结果相关。","authors":"Jung Hyun Choi, Myung-Jun Shin, Byeong-Ju Lee, Jae-Hyeong Park","doi":"10.1186/s40885-023-00256-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The six-minute walk test (6MWT) is an established exercise test for patients with pulmonary arterial hypertension (PAH), affording insight into both exercise intolerance and overall prognosis. Despite the widespread application of the 6MWT, the prognostic implications of exercise-induced desaturation (EID) during this test has been inadequately studied in PAH patients. Thus, we evaluated the occurrence of EID and its prognostic significance in PAH patients.</p><p><strong>Methods: </strong>We analyzed PAH patients in a single-center cohort from April 2016 to March 2021. EID was defined as a reduction in oxygen saturation exceeding 4% from the baseline or to below 90% at any point during the test.</p><p><strong>Results: </strong>We analyzed 20 PAH patients in this cohort, primarily consisting of 16 females with an average age of 48.4 ± 13.3 years. Among them, ten exhibited EID. Baseline characteristics, echocardiographic data and right heart catheterization data were similar between the two groups. However, total distance (354.3 ± 124.4 m vs. 485.4 ± 41.4 m, P = 0.019) and peak oxygen uptake (12.9 ± 3.2 mL/kg⋅min vs. 16.4 ± 3.6 mL/kg⋅min, P = 0.019) were significantly lower in the EID group. During the total follow-up duration of 51.9 ± 25.7 months, 17 patients had at least one adverse clinical event (2 deaths, 1 lung transplantation, and 13 hospital admissions). The presence of EID was associated with poor clinical outcome (hazard ratio = 6.099, 95% confidence interval = 1.783-20.869, P = 0.004).</p><p><strong>Conclusions: </strong>During the 6MWT, EID was observed in a half of PAH patients and emerged as a significant prognostic marker for adverse clinical events.</p>","PeriodicalId":10480,"journal":{"name":"Clinical Hypertension","volume":"29 1","pages":"33"},"PeriodicalIF":2.6000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691046/pdf/","citationCount":"0","resultStr":"{\"title\":\"Exercise-induced desaturation during a six-minute walk test is associated with poor clinical outcomes in patients with pulmonary arterial hypertension.\",\"authors\":\"Jung Hyun Choi, Myung-Jun Shin, Byeong-Ju Lee, Jae-Hyeong Park\",\"doi\":\"10.1186/s40885-023-00256-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The six-minute walk test (6MWT) is an established exercise test for patients with pulmonary arterial hypertension (PAH), affording insight into both exercise intolerance and overall prognosis. Despite the widespread application of the 6MWT, the prognostic implications of exercise-induced desaturation (EID) during this test has been inadequately studied in PAH patients. Thus, we evaluated the occurrence of EID and its prognostic significance in PAH patients.</p><p><strong>Methods: </strong>We analyzed PAH patients in a single-center cohort from April 2016 to March 2021. EID was defined as a reduction in oxygen saturation exceeding 4% from the baseline or to below 90% at any point during the test.</p><p><strong>Results: </strong>We analyzed 20 PAH patients in this cohort, primarily consisting of 16 females with an average age of 48.4 ± 13.3 years. Among them, ten exhibited EID. Baseline characteristics, echocardiographic data and right heart catheterization data were similar between the two groups. However, total distance (354.3 ± 124.4 m vs. 485.4 ± 41.4 m, P = 0.019) and peak oxygen uptake (12.9 ± 3.2 mL/kg⋅min vs. 16.4 ± 3.6 mL/kg⋅min, P = 0.019) were significantly lower in the EID group. During the total follow-up duration of 51.9 ± 25.7 months, 17 patients had at least one adverse clinical event (2 deaths, 1 lung transplantation, and 13 hospital admissions). The presence of EID was associated with poor clinical outcome (hazard ratio = 6.099, 95% confidence interval = 1.783-20.869, P = 0.004).</p><p><strong>Conclusions: </strong>During the 6MWT, EID was observed in a half of PAH patients and emerged as a significant prognostic marker for adverse clinical events.</p>\",\"PeriodicalId\":10480,\"journal\":{\"name\":\"Clinical Hypertension\",\"volume\":\"29 1\",\"pages\":\"33\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691046/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Hypertension\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s40885-023-00256-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Hypertension","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40885-023-00256-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
摘要
背景:6分钟步行试验(6MWT)是肺动脉高压(PAH)患者的既定运动试验,可以深入了解运动不耐受和整体预后。尽管6MWT被广泛应用,但在PAH患者中,这项测试中运动诱导的去饱和(EID)对预后的影响尚未得到充分研究。因此,我们评估了PAH患者EID的发生及其预后意义。方法:我们分析了2016年4月至2021年3月的单中心队列PAH患者。EID被定义为测试期间任何时刻血氧饱和度较基线降低超过4%或低于90%。结果:我们分析了该队列中20例PAH患者,主要包括16例女性,平均年龄为48.4±13.3岁。其中10例出现EID。基线特征、超声心动图数据和右心导管数据在两组之间相似。总距离(354.3±124.4 m vs. 485.4±41.4 m, P = 0.019)和峰值摄氧量(12.9±3.2 mL/kg·min vs. 16.4±3.6 mL/kg·min, P = 0.019)显著低于EID组。在51.9±25.7个月的总随访期间,17例患者至少发生一次临床不良事件(2例死亡,1例肺移植,13例住院)。EID的存在与不良的临床结果相关(风险比= 6.099,95%可信区间= 1.783-20.869,P = 0.004)。结论:在6MWT期间,半数PAH患者出现EID,并成为不良临床事件的重要预后指标。
Exercise-induced desaturation during a six-minute walk test is associated with poor clinical outcomes in patients with pulmonary arterial hypertension.
Background: The six-minute walk test (6MWT) is an established exercise test for patients with pulmonary arterial hypertension (PAH), affording insight into both exercise intolerance and overall prognosis. Despite the widespread application of the 6MWT, the prognostic implications of exercise-induced desaturation (EID) during this test has been inadequately studied in PAH patients. Thus, we evaluated the occurrence of EID and its prognostic significance in PAH patients.
Methods: We analyzed PAH patients in a single-center cohort from April 2016 to March 2021. EID was defined as a reduction in oxygen saturation exceeding 4% from the baseline or to below 90% at any point during the test.
Results: We analyzed 20 PAH patients in this cohort, primarily consisting of 16 females with an average age of 48.4 ± 13.3 years. Among them, ten exhibited EID. Baseline characteristics, echocardiographic data and right heart catheterization data were similar between the two groups. However, total distance (354.3 ± 124.4 m vs. 485.4 ± 41.4 m, P = 0.019) and peak oxygen uptake (12.9 ± 3.2 mL/kg⋅min vs. 16.4 ± 3.6 mL/kg⋅min, P = 0.019) were significantly lower in the EID group. During the total follow-up duration of 51.9 ± 25.7 months, 17 patients had at least one adverse clinical event (2 deaths, 1 lung transplantation, and 13 hospital admissions). The presence of EID was associated with poor clinical outcome (hazard ratio = 6.099, 95% confidence interval = 1.783-20.869, P = 0.004).
Conclusions: During the 6MWT, EID was observed in a half of PAH patients and emerged as a significant prognostic marker for adverse clinical events.