{"title":"在小儿心脏移植患者家中使用容积吸收式微采样和平行反应监测质谱法测量他克莫司血槽值","authors":"Junfang Zhao ,&nbsp;Kenneth D.R. Setchell ,&nbsp;Xueheng Zhao ,&nbsp;Stephanie Galandi ,&nbsp;BreAnn N Garr ,&nbsp;Zhiqian Gao ,&nbsp;Clifford Chin ,&nbsp;Shelly Stark ,&nbsp;Paul E. Steele ,&nbsp;Thomas D. Ryan","doi":"10.1016/j.jmsacl.2023.11.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Measurement of trough levels for calcineurin inhibitors by venipuncture sampling is a mainstay of patient management in solid organ transplant recipients but challenging in pediatric patients. Volumetric Absorptive Microsampling (VAMS) is a patient-friendly, minimally invasive sampling technique to accurately collect blood. An assay for measurement of tacrolimus in blood using VAMS, coupled with parallel reaction monitoring (PRM) mass spectrometry, was validated in pediatric heart transplant patients.</p></div><div><h3>Methods</h3><p>Tacrolimus was measured by a newly developed high-resolution PRM assay and compared with low-resolution tandem mass spectrometry (MRM). Dried blood samples were collected from pediatric heart transplant patients (n = 35) using VAMS devices and a satisfaction survey was completed by patients/guardians. Tacrolimus concentrations were compared across whole liquid blood, dried blood spots, and capillary blood, and shipping stability determined.</p></div><div><h3>Results</h3><p>The PRM assay was linear over a range 1–50 ng/mL, similar to MRM but had greater specificity due to reduced background noise. No significant differences in tacrolimus concentrations were observed between VAMS and venous blood. Tacrolimus dried on VAM tips was stable for 14 days and concentrations were unaffected by postal shipping. The variability in two simultaneously collected at-home patient samples was minimal – average concentration difference was 0.12 ± 0.94 ng/mL (<em>p</em> = 0.6) between paired samples.</p></div><div><h3>Conclusion</h3><p>A high resolution PRM mass spectrometry assay was developed for home-based dried blood collections for therapeutic monitoring of tacrolimus. The advantage of PRM was enhanced specificity and the VAMS devices provided a simple and convenient approach to blood sampling at home in pediatric heart transplant patients.</p></div>","PeriodicalId":52406,"journal":{"name":"Journal of Mass Spectrometry and Advances in the Clinical Lab","volume":"31 ","pages":"Pages 1-7"},"PeriodicalIF":3.1000,"publicationDate":"2023-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667145X2300038X/pdfft?md5=84de605382d2d53426e7420203b47793&pid=1-s2.0-S2667145X2300038X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Use of volumetric absorptive microsampling and parallel reaction monitoring mass spectrometry for tacrolimus blood trough measurements at home in pediatric heart transplant patients\",\"authors\":\"Junfang Zhao ,&nbsp;Kenneth D.R. Setchell ,&nbsp;Xueheng Zhao ,&nbsp;Stephanie Galandi ,&nbsp;BreAnn N Garr ,&nbsp;Zhiqian Gao ,&nbsp;Clifford Chin ,&nbsp;Shelly Stark ,&nbsp;Paul E. Steele ,&nbsp;Thomas D. Ryan\",\"doi\":\"10.1016/j.jmsacl.2023.11.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Measurement of trough levels for calcineurin inhibitors by venipuncture sampling is a mainstay of patient management in solid organ transplant recipients but challenging in pediatric patients. Volumetric Absorptive Microsampling (VAMS) is a patient-friendly, minimally invasive sampling technique to accurately collect blood. An assay for measurement of tacrolimus in blood using VAMS, coupled with parallel reaction monitoring (PRM) mass spectrometry, was validated in pediatric heart transplant patients.</p></div><div><h3>Methods</h3><p>Tacrolimus was measured by a newly developed high-resolution PRM assay and compared with low-resolution tandem mass spectrometry (MRM). Dried blood samples were collected from pediatric heart transplant patients (n = 35) using VAMS devices and a satisfaction survey was completed by patients/guardians. Tacrolimus concentrations were compared across whole liquid blood, dried blood spots, and capillary blood, and shipping stability determined.</p></div><div><h3>Results</h3><p>The PRM assay was linear over a range 1–50 ng/mL, similar to MRM but had greater specificity due to reduced background noise. No significant differences in tacrolimus concentrations were observed between VAMS and venous blood. Tacrolimus dried on VAM tips was stable for 14 days and concentrations were unaffected by postal shipping. The variability in two simultaneously collected at-home patient samples was minimal – average concentration difference was 0.12 ± 0.94 ng/mL (<em>p</em> = 0.6) between paired samples.</p></div><div><h3>Conclusion</h3><p>A high resolution PRM mass spectrometry assay was developed for home-based dried blood collections for therapeutic monitoring of tacrolimus. The advantage of PRM was enhanced specificity and the VAMS devices provided a simple and convenient approach to blood sampling at home in pediatric heart transplant patients.</p></div>\",\"PeriodicalId\":52406,\"journal\":{\"name\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"volume\":\"31 \",\"pages\":\"Pages 1-7\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2023-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2667145X2300038X/pdfft?md5=84de605382d2d53426e7420203b47793&pid=1-s2.0-S2667145X2300038X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667145X2300038X\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry and Advances in the Clinical Lab","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667145X2300038X","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景通过静脉穿刺采样测量钙神经蛋白抑制剂的谷值水平是实体器官移植受者患者管理的主要方法,但对儿科患者来说却具有挑战性。体积吸收微量采样(VAMS)是一种方便患者的微创采样技术,可准确采集血液。方法采用新开发的高分辨率 PRM 法测定血液中的他克莫司,并与低分辨率串联质谱法(MRM)进行比较。使用 VAMS 设备收集小儿心脏移植患者(35 人)的干血样本,并由患者/监护人填写满意度调查表。结果PRM测定在1-50纳克/毫升范围内呈线性,与MRM相似,但由于背景噪声降低,特异性更高。在 VAMS 和静脉血中未观察到他克莫司浓度的明显差异。干燥在 VAM 顶端的他克莫司在 14 天内保持稳定,浓度不受邮寄影响。两个同时采集的患者居家样本的变异性极小--配对样本之间的平均浓度差异为 0.12 ± 0.94 ng/mL(p = 0.6)。PRM 的优点是特异性更强,而 VAMS 设备为小儿心脏移植患者在家采血提供了一种简单方便的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Use of volumetric absorptive microsampling and parallel reaction monitoring mass spectrometry for tacrolimus blood trough measurements at home in pediatric heart transplant patients

Background

Measurement of trough levels for calcineurin inhibitors by venipuncture sampling is a mainstay of patient management in solid organ transplant recipients but challenging in pediatric patients. Volumetric Absorptive Microsampling (VAMS) is a patient-friendly, minimally invasive sampling technique to accurately collect blood. An assay for measurement of tacrolimus in blood using VAMS, coupled with parallel reaction monitoring (PRM) mass spectrometry, was validated in pediatric heart transplant patients.

Methods

Tacrolimus was measured by a newly developed high-resolution PRM assay and compared with low-resolution tandem mass spectrometry (MRM). Dried blood samples were collected from pediatric heart transplant patients (n = 35) using VAMS devices and a satisfaction survey was completed by patients/guardians. Tacrolimus concentrations were compared across whole liquid blood, dried blood spots, and capillary blood, and shipping stability determined.

Results

The PRM assay was linear over a range 1–50 ng/mL, similar to MRM but had greater specificity due to reduced background noise. No significant differences in tacrolimus concentrations were observed between VAMS and venous blood. Tacrolimus dried on VAM tips was stable for 14 days and concentrations were unaffected by postal shipping. The variability in two simultaneously collected at-home patient samples was minimal – average concentration difference was 0.12 ± 0.94 ng/mL (p = 0.6) between paired samples.

Conclusion

A high resolution PRM mass spectrometry assay was developed for home-based dried blood collections for therapeutic monitoring of tacrolimus. The advantage of PRM was enhanced specificity and the VAMS devices provided a simple and convenient approach to blood sampling at home in pediatric heart transplant patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Mass Spectrometry and Advances in the Clinical Lab
Journal of Mass Spectrometry and Advances in the Clinical Lab Health Professions-Medical Laboratory Technology
CiteScore
4.30
自引率
18.20%
发文量
41
审稿时长
81 days
期刊最新文献
Tandem mass spectrometry of serum cholestanoic (C27) acids – Typical concentration ranges and application to the study of peroxisomal biogenesis disorders Research letter: Pilot study of a prototype fully automated mass spectrometry system for routine clinical laboratory use Method validation of an inductively coupled plasma mass spectrometry (ICP-MS) assay for the analysis of magnesium, copper and zinc in red blood cells Liquid chromatography-mass spectrometric method for the simultaneous analysis of branched-chain amino acids and their ketoacids from dried blood spot as secondary analytes for the detection of maple syrup urine disease Development and validation of an LC-MS/MS method for highly concentrated tacrolimus and cyclosporine samples prepared from pharmaceutical products to assess drug loss from feeding tubes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1