{"title":"维生素 D3 的电化学传感:玻璃碳电极与未改性丝网印刷碳电极的比较使用","authors":"Fátima Daniela Gonçalves, José António Rodrigues, R. M. Ramos","doi":"10.3390/chemosensors11120575","DOIUrl":null,"url":null,"abstract":"This work presents the electrochemical determination of cholecalciferol (Vitamin D3) in water-organic mixtures using a glassy carbon electrode (GCE) and commercial screen-printed carbon electrodes (SPCEs). The electrocatalytic behavior of Vitamin D3 on the surface of the working electrode produced a well-defined oxidation peak at +0.95 V (vs. Ag|AgCl, 3.0 mol L−1) and +0.7 V (vs. Ag-SPCE pseudo-reference electrode) for the GCE and SPCE, respectively, in 0.1 M LiClO4 prepared in 50% ethanol. The nature of the organic solvent needed for the solubilization of Vitamin D3 was evaluated, together with the concentration of the supporting electrolyte, the ratio of the water-organic mixture, the voltametric parameters for the cyclic voltammetry (CV), and square-wave voltammetry (SWV) analyses. Under the optimized conditions, a linear correlation between the anodic peak current and the concentration of Vitamin D3 was obtained over the range of 0.47 to 123 µmol L−1 and 59.4 to 1651 µmol L−1 for the GCE and SPCE, respectively. The determined limits of detection (LOD) were 0.17 (GCE) and 19.4 µmol L−1 (SPCE). The methodology was successfully applied to commercial supplement tablets of Vitamin D3. Additionally, this work shows the possibility of using non-modified GCE and SPCE for routine analysis of Vitamin D3.","PeriodicalId":10057,"journal":{"name":"Chemosensors","volume":"25 2","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2023-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrochemical Sensing of Vitamin D3: A Comparative Use of Glassy Carbon and Unmodified Screen-Printed Carbon Electrodes\",\"authors\":\"Fátima Daniela Gonçalves, José António Rodrigues, R. M. Ramos\",\"doi\":\"10.3390/chemosensors11120575\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work presents the electrochemical determination of cholecalciferol (Vitamin D3) in water-organic mixtures using a glassy carbon electrode (GCE) and commercial screen-printed carbon electrodes (SPCEs). The electrocatalytic behavior of Vitamin D3 on the surface of the working electrode produced a well-defined oxidation peak at +0.95 V (vs. Ag|AgCl, 3.0 mol L−1) and +0.7 V (vs. Ag-SPCE pseudo-reference electrode) for the GCE and SPCE, respectively, in 0.1 M LiClO4 prepared in 50% ethanol. The nature of the organic solvent needed for the solubilization of Vitamin D3 was evaluated, together with the concentration of the supporting electrolyte, the ratio of the water-organic mixture, the voltametric parameters for the cyclic voltammetry (CV), and square-wave voltammetry (SWV) analyses. Under the optimized conditions, a linear correlation between the anodic peak current and the concentration of Vitamin D3 was obtained over the range of 0.47 to 123 µmol L−1 and 59.4 to 1651 µmol L−1 for the GCE and SPCE, respectively. The determined limits of detection (LOD) were 0.17 (GCE) and 19.4 µmol L−1 (SPCE). The methodology was successfully applied to commercial supplement tablets of Vitamin D3. Additionally, this work shows the possibility of using non-modified GCE and SPCE for routine analysis of Vitamin D3.\",\"PeriodicalId\":10057,\"journal\":{\"name\":\"Chemosensors\",\"volume\":\"25 2\",\"pages\":\"\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-12-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemosensors\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/chemosensors11120575\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemosensors","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/chemosensors11120575","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了利用玻璃碳电极(GCE)和商业丝网印刷碳电极(SPCEs)电化学测定水-有机混合物中胆钙化醇(维生素D3)的方法。在50%乙醇中制备的0.1 M LiClO4中,维生素D3在工作电极表面的电催化行为产生了明确的氧化峰,分别为+0.95 V (vs. Ag|AgCl, 3.0 mol L−1)和+0.7 V (vs. Ag-SPCE伪参比电极)。考察了维生素D3增溶所需的有机溶剂的性质,以及支持电解质的浓度、水-有机混合物的比例、循环伏安法(CV)和方波伏安法(SWV)分析的伏安参数。在优化条件下,GCE和SPCE的阳极峰电流与维生素D3浓度分别在0.47 ~ 123µmol L−1和59.4 ~ 1651µmol L−1范围内呈线性相关。测定的检出限(LOD)分别为0.17 (GCE)和19.4µmol L−1 (SPCE)。该方法已成功地应用于商业维生素D3补充剂片。此外,这项工作显示了使用未修饰的GCE和SPCE进行维生素D3常规分析的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Electrochemical Sensing of Vitamin D3: A Comparative Use of Glassy Carbon and Unmodified Screen-Printed Carbon Electrodes
This work presents the electrochemical determination of cholecalciferol (Vitamin D3) in water-organic mixtures using a glassy carbon electrode (GCE) and commercial screen-printed carbon electrodes (SPCEs). The electrocatalytic behavior of Vitamin D3 on the surface of the working electrode produced a well-defined oxidation peak at +0.95 V (vs. Ag|AgCl, 3.0 mol L−1) and +0.7 V (vs. Ag-SPCE pseudo-reference electrode) for the GCE and SPCE, respectively, in 0.1 M LiClO4 prepared in 50% ethanol. The nature of the organic solvent needed for the solubilization of Vitamin D3 was evaluated, together with the concentration of the supporting electrolyte, the ratio of the water-organic mixture, the voltametric parameters for the cyclic voltammetry (CV), and square-wave voltammetry (SWV) analyses. Under the optimized conditions, a linear correlation between the anodic peak current and the concentration of Vitamin D3 was obtained over the range of 0.47 to 123 µmol L−1 and 59.4 to 1651 µmol L−1 for the GCE and SPCE, respectively. The determined limits of detection (LOD) were 0.17 (GCE) and 19.4 µmol L−1 (SPCE). The methodology was successfully applied to commercial supplement tablets of Vitamin D3. Additionally, this work shows the possibility of using non-modified GCE and SPCE for routine analysis of Vitamin D3.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Chemosensors
Chemosensors Chemistry-Analytical Chemistry
CiteScore
5.00
自引率
9.50%
发文量
450
审稿时长
11 weeks
期刊介绍: Chemosensors (ISSN 2227-9040; CODEN: CHEMO9) is an international, scientific, open access journal on the science and technology of chemical sensors published quarterly online by MDPI.The journal is indexed in Scopus, SCIE (Web of Science), CAPlus / SciFinder, Inspec, Engineering Village and other databases.
期刊最新文献
Prostate Cancer Detection in Colombian Patients through E-Senses Devices in Exhaled Breath and Urine Samples Origami Paper-Based Electrochemical Immunosensor with Carbon Nanohorns-Decorated Nanoporous Gold for Zearalenone Detection Spectroscopy and Chemometrics for Conformity Analysis of e-Liquids: Illegal Additive Detection and Nicotine Characterization Nanorods Assembled Hierarchical Bi2S3 for Highly Sensitive Detection of Trace NO2 at Room Temperature Evaluation of the Essential Oil Composition of Five Thymus Species Native to Greece
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1