利用可再生能源和毛细管换热器为现有公寓节约能源

IF 0.5 Q4 PHYSICS, APPLIED Latvian Journal of Physics and Technical Sciences Pub Date : 2023-12-01 DOI:10.2478/lpts-2023-0046
S. Gendelis, A. Jakovics, O. Pulkis, I. Bukans
{"title":"利用可再生能源和毛细管换热器为现有公寓节约能源","authors":"S. Gendelis, A. Jakovics, O. Pulkis, I. Bukans","doi":"10.2478/lpts-2023-0046","DOIUrl":null,"url":null,"abstract":"Abstract The use of capillary heat exchangers with a large area means the lowest heat carrier temperature – typically less than 30 °C for heating. This determines the very efficient use of the installed heat pump due to an increase in the coefficient of performance (COP) with a decrease in the provided water temperature. The aim of the study was to find out whether renewable energy sources and radiant capillary heat exchangers increase energy efficiency. In order to achieve the maximum energy efficiency during the renovation of the existing apartment, a combination of two green approaches was used. One of them is the replacement of the existing high-temperature radiator heating system with radiant capillary mats. The same system is also used for cooling, which was not possible with the existing system. The necessary energy is provided from renewable aerothermal energy by installing a heat pump together with PV panels to ensure electricity consumption. The measurements were made in the apartment to determine the thermal transmission properties of all boundary structures and an air exchange rate using long-term monitoring. Experimental data were used to create the heat balance, to estimate the heating and cooling powers, as well as the seasonal energy needs. The amount of capillary heat exchangers and the size of the heat pump were chosen accordingly. The very first energy consumption data allow concluding that the planned improvement of the energy efficiency has been successfully achieved by using technology combination described without improvement of the thermal properties.","PeriodicalId":43603,"journal":{"name":"Latvian Journal of Physics and Technical Sciences","volume":" 7","pages":"71 - 80"},"PeriodicalIF":0.5000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Use of Renewable Energy and Capillary Heat Exchangers for Energy Savings in the Existing Apartment\",\"authors\":\"S. Gendelis, A. Jakovics, O. Pulkis, I. Bukans\",\"doi\":\"10.2478/lpts-2023-0046\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The use of capillary heat exchangers with a large area means the lowest heat carrier temperature – typically less than 30 °C for heating. This determines the very efficient use of the installed heat pump due to an increase in the coefficient of performance (COP) with a decrease in the provided water temperature. The aim of the study was to find out whether renewable energy sources and radiant capillary heat exchangers increase energy efficiency. In order to achieve the maximum energy efficiency during the renovation of the existing apartment, a combination of two green approaches was used. One of them is the replacement of the existing high-temperature radiator heating system with radiant capillary mats. The same system is also used for cooling, which was not possible with the existing system. The necessary energy is provided from renewable aerothermal energy by installing a heat pump together with PV panels to ensure electricity consumption. The measurements were made in the apartment to determine the thermal transmission properties of all boundary structures and an air exchange rate using long-term monitoring. Experimental data were used to create the heat balance, to estimate the heating and cooling powers, as well as the seasonal energy needs. The amount of capillary heat exchangers and the size of the heat pump were chosen accordingly. The very first energy consumption data allow concluding that the planned improvement of the energy efficiency has been successfully achieved by using technology combination described without improvement of the thermal properties.\",\"PeriodicalId\":43603,\"journal\":{\"name\":\"Latvian Journal of Physics and Technical Sciences\",\"volume\":\" 7\",\"pages\":\"71 - 80\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Latvian Journal of Physics and Technical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/lpts-2023-0046\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Latvian Journal of Physics and Technical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/lpts-2023-0046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

摘要

使用面积大的毛细热交换器意味着最低的热载体温度-通常小于30°C进行加热。由于性能系数(COP)随着提供的水温的降低而增加,这决定了安装的热泵的非常有效的使用。这项研究的目的是找出可再生能源和辐射毛细管热交换器是否能提高能源效率。为了在现有公寓的改造过程中实现最大的能源效率,我们使用了两种绿色方法的组合。其中之一是用辐射毛细垫代替现有的高温散热器供暖系统。同样的系统也用于冷却,这在现有的系统中是不可能的。所需的能量来自可再生的空气热能源,通过安装热泵和光伏板来确保电力消耗。测量是在公寓内进行的,以确定所有边界结构的传热特性,并通过长期监测确定空气交换率。实验数据用于创建热平衡,以估计加热和冷却功率,以及季节性能源需求。对毛细管换热器的数量和热泵的尺寸进行了相应的选择。第一个能耗数据可以得出结论,通过使用所描述的技术组合,在不改善热性能的情况下,成功地实现了计划中的能效改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Use of Renewable Energy and Capillary Heat Exchangers for Energy Savings in the Existing Apartment
Abstract The use of capillary heat exchangers with a large area means the lowest heat carrier temperature – typically less than 30 °C for heating. This determines the very efficient use of the installed heat pump due to an increase in the coefficient of performance (COP) with a decrease in the provided water temperature. The aim of the study was to find out whether renewable energy sources and radiant capillary heat exchangers increase energy efficiency. In order to achieve the maximum energy efficiency during the renovation of the existing apartment, a combination of two green approaches was used. One of them is the replacement of the existing high-temperature radiator heating system with radiant capillary mats. The same system is also used for cooling, which was not possible with the existing system. The necessary energy is provided from renewable aerothermal energy by installing a heat pump together with PV panels to ensure electricity consumption. The measurements were made in the apartment to determine the thermal transmission properties of all boundary structures and an air exchange rate using long-term monitoring. Experimental data were used to create the heat balance, to estimate the heating and cooling powers, as well as the seasonal energy needs. The amount of capillary heat exchangers and the size of the heat pump were chosen accordingly. The very first energy consumption data allow concluding that the planned improvement of the energy efficiency has been successfully achieved by using technology combination described without improvement of the thermal properties.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.50
自引率
16.70%
发文量
41
审稿时长
5 weeks
期刊介绍: Latvian Journal of Physics and Technical Sciences (Latvijas Fizikas un Tehnisko Zinātņu Žurnāls) publishes experimental and theoretical papers containing results not published previously and review articles. Its scope includes Energy and Power, Energy Engineering, Energy Policy and Economics, Physical Sciences, Physics and Applied Physics in Engineering, Astronomy and Spectroscopy.
期刊最新文献
The Use of Renewable Energy and Capillary Heat Exchangers for Energy Savings in the Existing Apartment Modelling of Methanol Production From Biogas Applying Dynamic U-Value Measurements for State Forecasting in Buildings Numerical Insights Into Gas Mixing System Design for Energy Conversion Processes Density-Based Topological Optimization of 3D-Printed Casts for Fracture Treatment with Freefem Software
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1