静脉血栓栓塞症 ICD-10 编码的准确性:系统回顾与荟萃分析

Q4 Medicine Thrombosis Update Pub Date : 2023-12-07 DOI:10.1016/j.tru.2023.100154
Bonnie Liu , Milena Hadzi-Tosev , Kerolos Eisa , Yang Liu , Kayla J. Lucier , Anchit Garg , Sophie Li , Emily Xu , Siraj Mithoowani , Rick Ikesaka , Nancy M. Heddle , Bram Rochwerg , Shuoyan Ning
{"title":"静脉血栓栓塞症 ICD-10 编码的准确性:系统回顾与荟萃分析","authors":"Bonnie Liu ,&nbsp;Milena Hadzi-Tosev ,&nbsp;Kerolos Eisa ,&nbsp;Yang Liu ,&nbsp;Kayla J. Lucier ,&nbsp;Anchit Garg ,&nbsp;Sophie Li ,&nbsp;Emily Xu ,&nbsp;Siraj Mithoowani ,&nbsp;Rick Ikesaka ,&nbsp;Nancy M. Heddle ,&nbsp;Bram Rochwerg ,&nbsp;Shuoyan Ning","doi":"10.1016/j.tru.2023.100154","DOIUrl":null,"url":null,"abstract":"<div><h3>Aims</h3><p>The identification of venous thromboembolism (VTE) using administrative databases is frequently required for reporting and research. The accuracy of International Classification of Diseases 10th revision (ICD-10) codes for VTE, including deep vein thrombosis (DVT) and pulmonary embolism (PE), remains unclear. We examined the accuracy of ICD-10 codes for identifying VTE in adult and pediatric inpatients and outpatients.</p></div><div><h3>Methods</h3><p>For this systematic review and meta-analysis, we searched MEDLINE, EMBASE, Web of Science, CENTRAL, Epistemonikos and McMaster Superfilters from inception to July 25, 2023 for studies evaluating the sensitivity, specificity, positive predictive value (PPV), and/or negative predictive value (NPV) of ICD-10 codes for VTE in any anatomical location. We assessed risk of bias using QUADAS and certainty of evidence using GRADE. We calculated pooled sensitivity and specificity with 95% confidence intervals (CI) using a random-effects model.</p></div><div><h3>Results</h3><p>We included 24 studies in the qualitative synthesis and 7 in the meta-analysis. Pooled sensitivity for any VTE based on ICD-10 codes was 72% (95% CI 60–85%, low certainty); pooled specificity was 82% (95% CI 76–88%, low certainty). The PPV for ICD-10 VTE codes ranged from 0% to 100% (median: 80%) while the NPV ranged from 95.4% to 100% (median: 100%). ICD-10 codes for PE had a higher pooled sensitivity (91%) than for DVT (58%).</p></div><div><h3>Conclusion</h3><p>ICD-10 codes have moderate-to-high sensitivity and specificity for the identification of VTE in electronic databases. The certainty of evidence is low due to inconsistency and risk of bias. Further robust studies validating ICD-10 VTE codes are needed to improve reporting and better understand coding limitations.</p></div>","PeriodicalId":34401,"journal":{"name":"Thrombosis Update","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666572723000251/pdfft?md5=d9c7cc2a5966192349b83bd22da9efe8&pid=1-s2.0-S2666572723000251-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Accuracy of venous thromboembolism ICD-10 codes: A systematic review and meta-analysis\",\"authors\":\"Bonnie Liu ,&nbsp;Milena Hadzi-Tosev ,&nbsp;Kerolos Eisa ,&nbsp;Yang Liu ,&nbsp;Kayla J. Lucier ,&nbsp;Anchit Garg ,&nbsp;Sophie Li ,&nbsp;Emily Xu ,&nbsp;Siraj Mithoowani ,&nbsp;Rick Ikesaka ,&nbsp;Nancy M. Heddle ,&nbsp;Bram Rochwerg ,&nbsp;Shuoyan Ning\",\"doi\":\"10.1016/j.tru.2023.100154\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Aims</h3><p>The identification of venous thromboembolism (VTE) using administrative databases is frequently required for reporting and research. The accuracy of International Classification of Diseases 10th revision (ICD-10) codes for VTE, including deep vein thrombosis (DVT) and pulmonary embolism (PE), remains unclear. We examined the accuracy of ICD-10 codes for identifying VTE in adult and pediatric inpatients and outpatients.</p></div><div><h3>Methods</h3><p>For this systematic review and meta-analysis, we searched MEDLINE, EMBASE, Web of Science, CENTRAL, Epistemonikos and McMaster Superfilters from inception to July 25, 2023 for studies evaluating the sensitivity, specificity, positive predictive value (PPV), and/or negative predictive value (NPV) of ICD-10 codes for VTE in any anatomical location. We assessed risk of bias using QUADAS and certainty of evidence using GRADE. We calculated pooled sensitivity and specificity with 95% confidence intervals (CI) using a random-effects model.</p></div><div><h3>Results</h3><p>We included 24 studies in the qualitative synthesis and 7 in the meta-analysis. Pooled sensitivity for any VTE based on ICD-10 codes was 72% (95% CI 60–85%, low certainty); pooled specificity was 82% (95% CI 76–88%, low certainty). The PPV for ICD-10 VTE codes ranged from 0% to 100% (median: 80%) while the NPV ranged from 95.4% to 100% (median: 100%). ICD-10 codes for PE had a higher pooled sensitivity (91%) than for DVT (58%).</p></div><div><h3>Conclusion</h3><p>ICD-10 codes have moderate-to-high sensitivity and specificity for the identification of VTE in electronic databases. The certainty of evidence is low due to inconsistency and risk of bias. Further robust studies validating ICD-10 VTE codes are needed to improve reporting and better understand coding limitations.</p></div>\",\"PeriodicalId\":34401,\"journal\":{\"name\":\"Thrombosis Update\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666572723000251/pdfft?md5=d9c7cc2a5966192349b83bd22da9efe8&pid=1-s2.0-S2666572723000251-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Thrombosis Update\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666572723000251\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thrombosis Update","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666572723000251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:在报告和研究中,经常需要使用管理数据库来识别静脉血栓栓塞(VTE)。国际疾病分类第10版(ICD-10) VTE编码的准确性仍不清楚,包括深静脉血栓形成(DVT)和肺栓塞(PE)。我们检查了ICD-10代码在成人和儿科住院和门诊患者中识别静脉血栓栓塞的准确性。方法在本系统综述和荟萃分析中,我们检索了MEDLINE、EMBASE、Web of Science、CENTRAL、Epistemonikos和McMaster Superfilters从成立到2023年7月25日的研究,以评估ICD-10编码在任何解剖位置的静脉栓塞的敏感性、特异性、阳性预测值(PPV)和/或阴性预测值(NPV)。我们使用QUADAS评估偏倚风险,使用GRADE评估证据的确定性。我们使用随机效应模型计算95%置信区间(CI)的合并敏感性和特异性。结果定性综合纳入24项研究,meta分析纳入7项研究。基于ICD-10编码的VTE的总敏感性为72% (95% CI 60-85%,低确定性);合并特异性为82% (95% CI 76-88%,低确定性)。ICD-10 VTE编码的PPV范围为0% ~ 100%(中位数:80%),NPV范围为95.4% ~ 100%(中位数:100%)。ICD-10编码对PE的总灵敏度(91%)高于DVT(58%)。结论icd -10编码对电子数据库中VTE的鉴别具有中高灵敏度和特异性。由于不一致和存在偏倚风险,证据的确定性较低。需要进一步的研究来验证ICD-10 VTE编码,以改进报告并更好地理解编码的局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accuracy of venous thromboembolism ICD-10 codes: A systematic review and meta-analysis

Aims

The identification of venous thromboembolism (VTE) using administrative databases is frequently required for reporting and research. The accuracy of International Classification of Diseases 10th revision (ICD-10) codes for VTE, including deep vein thrombosis (DVT) and pulmonary embolism (PE), remains unclear. We examined the accuracy of ICD-10 codes for identifying VTE in adult and pediatric inpatients and outpatients.

Methods

For this systematic review and meta-analysis, we searched MEDLINE, EMBASE, Web of Science, CENTRAL, Epistemonikos and McMaster Superfilters from inception to July 25, 2023 for studies evaluating the sensitivity, specificity, positive predictive value (PPV), and/or negative predictive value (NPV) of ICD-10 codes for VTE in any anatomical location. We assessed risk of bias using QUADAS and certainty of evidence using GRADE. We calculated pooled sensitivity and specificity with 95% confidence intervals (CI) using a random-effects model.

Results

We included 24 studies in the qualitative synthesis and 7 in the meta-analysis. Pooled sensitivity for any VTE based on ICD-10 codes was 72% (95% CI 60–85%, low certainty); pooled specificity was 82% (95% CI 76–88%, low certainty). The PPV for ICD-10 VTE codes ranged from 0% to 100% (median: 80%) while the NPV ranged from 95.4% to 100% (median: 100%). ICD-10 codes for PE had a higher pooled sensitivity (91%) than for DVT (58%).

Conclusion

ICD-10 codes have moderate-to-high sensitivity and specificity for the identification of VTE in electronic databases. The certainty of evidence is low due to inconsistency and risk of bias. Further robust studies validating ICD-10 VTE codes are needed to improve reporting and better understand coding limitations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Thrombosis Update
Thrombosis Update Medicine-Hematology
CiteScore
1.90
自引率
0.00%
发文量
33
审稿时长
86 days
期刊最新文献
Tissue factor (F3) gene variants and thrombotic risk among middle-aged and older adults: A population-based cohort study Catheter – related thrombosis in cancer patients: Data from the registry of thrombosis and nEoplasia of SEOM (TESEO) Usability study of the qLabs® FIB: A new point-of-care system for functional fibrinogen testing Nitrous oxide and VTE – no laughing matter Practical model for implementation of cancer-associated thrombosis prevention in the outpatient setting
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1