利用功能化单壁碳纳米管超薄薄膜在水介质中选择性传感氟离子

Parul Taneja, V Manjuladevi, R K Gupta, K K Gupta
{"title":"利用功能化单壁碳纳米管超薄薄膜在水介质中选择性传感氟离子","authors":"Parul Taneja, V Manjuladevi, R K Gupta, K K Gupta","doi":"10.1088/2632-959x/ad0fa7","DOIUrl":null,"url":null,"abstract":"The presence of fluoride ion (F<sup>\n<bold>-</bold>\n</sup>) in potable water above its permissible limit (1–4 ppm) poses serious health hazards. Hence, detection of fluoride in potable water is essential. The <italic toggle=\"yes\">π</italic>-electron rich single-walled carbon nanotubes can interact with F<sup>-</sup> to form semi-covalent C-F bond which can act as a basis for F<sup>\n<bold>-</bold>\n</sup> sensing in aqueous medium. Here, a single layer of octadecylamine functionalized single-walled carbon nanotubes (ODA-SWCNTs) was transferred onto solid substrates by the Langmuir–Schaefer (LS) method and employed for sensing of F- in aqueous medium by recording piezo and electrochemical responses, simultaneously using an electrochemical quartz crystal microbalance. The lowest detectable concentration and range of detectable concentration of fluoride ion were found to be 0.5 ppm and 0.5–145 ppm, respectively. The analysis of the LS film of ODA-SWCNTs before and after interaction with fluoride ion by Raman spectroscopy and grazing angle x-ray diffraction measurement reveals perturbation of <italic toggle=\"yes\">π</italic>-electrons of the SWCNTs due to semi-covalent binding of the fluoride with the carbon atom of the nanotubes. The sensor showed a good selectivity towards the F<sup>-</sup> in the presence of some heavy metal ions. Testing of the sensor towards F<sup>-</sup> in tap water obtained from some local region showed a good accuracy.","PeriodicalId":501827,"journal":{"name":"Nano Express","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Selective fluoride ion sensing in aqueous medium using ultrathin film of functionalized single-walled carbon nanotubes\",\"authors\":\"Parul Taneja, V Manjuladevi, R K Gupta, K K Gupta\",\"doi\":\"10.1088/2632-959x/ad0fa7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The presence of fluoride ion (F<sup>\\n<bold>-</bold>\\n</sup>) in potable water above its permissible limit (1–4 ppm) poses serious health hazards. Hence, detection of fluoride in potable water is essential. The <italic toggle=\\\"yes\\\">π</italic>-electron rich single-walled carbon nanotubes can interact with F<sup>-</sup> to form semi-covalent C-F bond which can act as a basis for F<sup>\\n<bold>-</bold>\\n</sup> sensing in aqueous medium. Here, a single layer of octadecylamine functionalized single-walled carbon nanotubes (ODA-SWCNTs) was transferred onto solid substrates by the Langmuir–Schaefer (LS) method and employed for sensing of F- in aqueous medium by recording piezo and electrochemical responses, simultaneously using an electrochemical quartz crystal microbalance. The lowest detectable concentration and range of detectable concentration of fluoride ion were found to be 0.5 ppm and 0.5–145 ppm, respectively. The analysis of the LS film of ODA-SWCNTs before and after interaction with fluoride ion by Raman spectroscopy and grazing angle x-ray diffraction measurement reveals perturbation of <italic toggle=\\\"yes\\\">π</italic>-electrons of the SWCNTs due to semi-covalent binding of the fluoride with the carbon atom of the nanotubes. The sensor showed a good selectivity towards the F<sup>-</sup> in the presence of some heavy metal ions. Testing of the sensor towards F<sup>-</sup> in tap water obtained from some local region showed a good accuracy.\",\"PeriodicalId\":501827,\"journal\":{\"name\":\"Nano Express\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nano Express\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/2632-959x/ad0fa7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nano Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2632-959x/ad0fa7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

饮用水中的氟离子(F-)含量超过允许极限(1-4 ppm)会对健康造成严重危害。因此,检测饮用水中的氟至关重要。富含 π 电子的单壁碳纳米管能与 F- 相互作用,形成半共价的 C-F 键,这可以作为水介质中 F- 检测的基础。在此,我们采用 Langmuir-Schaefer (LS) 方法将单层十八胺功能化单壁碳纳米管(ODA-SWCNTs)转移到固体基底上,并利用电化学石英晶体微天平同时记录压电和电化学响应,从而用于水介质中 F- 的传感。结果发现,氟离子的最低可检测浓度和可检测浓度范围分别为 0.5 ppm 和 0.5-145 ppm。通过拉曼光谱和掠角 X 射线衍射测量对与氟离子相互作用前后的 ODA-SWCNT LS 薄膜进行的分析表明,由于氟与纳米管碳原子的半共价结合,SWCNT 的 π 电子发生了扰动。在一些重金属离子存在的情况下,该传感器对氟离子具有良好的选择性。在当地一些地区的自来水中对传感器进行的氟离子测试表明,该传感器具有良好的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Selective fluoride ion sensing in aqueous medium using ultrathin film of functionalized single-walled carbon nanotubes
The presence of fluoride ion (F - ) in potable water above its permissible limit (1–4 ppm) poses serious health hazards. Hence, detection of fluoride in potable water is essential. The π-electron rich single-walled carbon nanotubes can interact with F- to form semi-covalent C-F bond which can act as a basis for F - sensing in aqueous medium. Here, a single layer of octadecylamine functionalized single-walled carbon nanotubes (ODA-SWCNTs) was transferred onto solid substrates by the Langmuir–Schaefer (LS) method and employed for sensing of F- in aqueous medium by recording piezo and electrochemical responses, simultaneously using an electrochemical quartz crystal microbalance. The lowest detectable concentration and range of detectable concentration of fluoride ion were found to be 0.5 ppm and 0.5–145 ppm, respectively. The analysis of the LS film of ODA-SWCNTs before and after interaction with fluoride ion by Raman spectroscopy and grazing angle x-ray diffraction measurement reveals perturbation of π-electrons of the SWCNTs due to semi-covalent binding of the fluoride with the carbon atom of the nanotubes. The sensor showed a good selectivity towards the F- in the presence of some heavy metal ions. Testing of the sensor towards F- in tap water obtained from some local region showed a good accuracy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Synthesis, characterization and magneto-structural properties of geometrical and compositional modulated nanowires A comparative study of broadband PbS quantum dots/graphene photodetectors with monolayer and bilayer graphene Occurrence of the collective Ziman limit of heat transport in cubic semiconductors Si, Ge, AlAs and AlP: scattering channels and size effects Structure and optical properties of ZnxCd1-xS and Cu:ZnxCd1-xS templated on DNA molecules Lycium ruthenicum stem extract mediated green synthesis of MnO2/Mn3(PO4)2 composite nanowire electrocatalyst for oxygen evolution reaction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1