开发和验证用于分析母乳中贝达喹啉和 M2 的液相色谱串联质谱分析法

IF 3.1 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY Journal of Mass Spectrometry and Advances in the Clinical Lab Pub Date : 2023-12-13 DOI:10.1016/j.jmsacl.2023.12.001
Buyisile Mkhize, Richard Court, Sandra Castel, Anton Joubert, Marthinus van der Merwe, Lubbe Wiesner
{"title":"开发和验证用于分析母乳中贝达喹啉和 M2 的液相色谱串联质谱分析法","authors":"Buyisile Mkhize,&nbsp;Richard Court,&nbsp;Sandra Castel,&nbsp;Anton Joubert,&nbsp;Marthinus van der Merwe,&nbsp;Lubbe Wiesner","doi":"10.1016/j.jmsacl.2023.12.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>To develop and validate an assay for the analysis of bedaquiline and its M2 metabolite in human breast milk.</p></div><div><h3>Methods</h3><p>The analytes were extracted using solid phase extraction following protein precipitation. Quantification was performed with liquid chromatography coupled with tandem mass spectrometry. Chromatographic separation was achieved using gradient chromatography on a Poroshell 120 SB-C18 analytical column at 40 °C, with a flow rate of 350 µL/minute and a total run time of eight minutes. An AB Sciex 3000 mass spectrometer with electrospray ionization in the positive mode was used for detection, employing multiple reaction monitoring scan mode. Bedaquiline-d6 and M2-d3-<sup>13</sup>C were used as internal standards.</p></div><div><h3>Results</h3><p>Calibrations curves for bedaquiline and M2 exhibited quadratic (weighted 1/x concentration) regressions over the respective concentration ranges of 0.0780 to 5.00 µg/mL and 0.0312 to 2.00 µg/mL. Inter- and intra-day validation accuracies ranged between 96.7 % and 103.5 % for bedaquiline, and 104.2 % to 106.5 % for M2, with a coefficient of variation below 9.2 % for both compounds.</p></div><div><h3>Conclusion</h3><p>The developed assay demonstrated selectivity and robustness, enabling differentiation between bedaquiline and M2 within the context of endogenous compounds from six separate lots of breast milk samples. Successful application was observed in the analysis of breast milk samples sourced from patients treated for multidrug-resistant tuberculosis within a clinical study setting.</p></div>","PeriodicalId":52406,"journal":{"name":"Journal of Mass Spectrometry and Advances in the Clinical Lab","volume":"31 ","pages":"Pages 8-16"},"PeriodicalIF":3.1000,"publicationDate":"2023-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667145X23000391/pdfft?md5=10be0ce9af33a42047481730cdb66b49&pid=1-s2.0-S2667145X23000391-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Development and validation of a liquid chromatography tandem mass spectrometry assay for the analysis of bedaquiline and M2 in breast milk\",\"authors\":\"Buyisile Mkhize,&nbsp;Richard Court,&nbsp;Sandra Castel,&nbsp;Anton Joubert,&nbsp;Marthinus van der Merwe,&nbsp;Lubbe Wiesner\",\"doi\":\"10.1016/j.jmsacl.2023.12.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>To develop and validate an assay for the analysis of bedaquiline and its M2 metabolite in human breast milk.</p></div><div><h3>Methods</h3><p>The analytes were extracted using solid phase extraction following protein precipitation. Quantification was performed with liquid chromatography coupled with tandem mass spectrometry. Chromatographic separation was achieved using gradient chromatography on a Poroshell 120 SB-C18 analytical column at 40 °C, with a flow rate of 350 µL/minute and a total run time of eight minutes. An AB Sciex 3000 mass spectrometer with electrospray ionization in the positive mode was used for detection, employing multiple reaction monitoring scan mode. Bedaquiline-d6 and M2-d3-<sup>13</sup>C were used as internal standards.</p></div><div><h3>Results</h3><p>Calibrations curves for bedaquiline and M2 exhibited quadratic (weighted 1/x concentration) regressions over the respective concentration ranges of 0.0780 to 5.00 µg/mL and 0.0312 to 2.00 µg/mL. Inter- and intra-day validation accuracies ranged between 96.7 % and 103.5 % for bedaquiline, and 104.2 % to 106.5 % for M2, with a coefficient of variation below 9.2 % for both compounds.</p></div><div><h3>Conclusion</h3><p>The developed assay demonstrated selectivity and robustness, enabling differentiation between bedaquiline and M2 within the context of endogenous compounds from six separate lots of breast milk samples. Successful application was observed in the analysis of breast milk samples sourced from patients treated for multidrug-resistant tuberculosis within a clinical study setting.</p></div>\",\"PeriodicalId\":52406,\"journal\":{\"name\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"volume\":\"31 \",\"pages\":\"Pages 8-16\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2023-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2667145X23000391/pdfft?md5=10be0ce9af33a42047481730cdb66b49&pid=1-s2.0-S2667145X23000391-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667145X23000391\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry and Advances in the Clinical Lab","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667145X23000391","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

方法 在蛋白质沉淀后采用固相萃取法提取分析物。采用液相色谱-串联质谱法进行定量。采用梯度色谱法在 Poroshell 120 SB-C18 分析柱上进行色谱分离,分离温度为 40 °C,流速为 350 µL/分钟,总运行时间为 8 分钟。AB Sciex 3000 质谱仪采用多反应监测扫描模式,在正离子模式下进行电喷雾离子化检测。结果贝达喹啉和 M2 的校准曲线在 0.0780 至 5.00 µg/mL 和 0.0312 至 2.00 µg/mL 的浓度范围内分别呈现二次(加权 1/x 浓度)回归。贝达喹啉的日间和日内验证准确度在 96.7 % 至 103.5 % 之间,M2 的准确度在 104.2 % 至 106.5 % 之间,两种化合物的变异系数均低于 9.2 %。在一项临床研究中,对来自耐多药结核病患者的母乳样本进行分析,取得了成功。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development and validation of a liquid chromatography tandem mass spectrometry assay for the analysis of bedaquiline and M2 in breast milk

Objective

To develop and validate an assay for the analysis of bedaquiline and its M2 metabolite in human breast milk.

Methods

The analytes were extracted using solid phase extraction following protein precipitation. Quantification was performed with liquid chromatography coupled with tandem mass spectrometry. Chromatographic separation was achieved using gradient chromatography on a Poroshell 120 SB-C18 analytical column at 40 °C, with a flow rate of 350 µL/minute and a total run time of eight minutes. An AB Sciex 3000 mass spectrometer with electrospray ionization in the positive mode was used for detection, employing multiple reaction monitoring scan mode. Bedaquiline-d6 and M2-d3-13C were used as internal standards.

Results

Calibrations curves for bedaquiline and M2 exhibited quadratic (weighted 1/x concentration) regressions over the respective concentration ranges of 0.0780 to 5.00 µg/mL and 0.0312 to 2.00 µg/mL. Inter- and intra-day validation accuracies ranged between 96.7 % and 103.5 % for bedaquiline, and 104.2 % to 106.5 % for M2, with a coefficient of variation below 9.2 % for both compounds.

Conclusion

The developed assay demonstrated selectivity and robustness, enabling differentiation between bedaquiline and M2 within the context of endogenous compounds from six separate lots of breast milk samples. Successful application was observed in the analysis of breast milk samples sourced from patients treated for multidrug-resistant tuberculosis within a clinical study setting.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Mass Spectrometry and Advances in the Clinical Lab
Journal of Mass Spectrometry and Advances in the Clinical Lab Health Professions-Medical Laboratory Technology
CiteScore
4.30
自引率
18.20%
发文量
41
审稿时长
81 days
期刊最新文献
Tandem mass spectrometry of serum cholestanoic (C27) acids – Typical concentration ranges and application to the study of peroxisomal biogenesis disorders Research letter: Pilot study of a prototype fully automated mass spectrometry system for routine clinical laboratory use Development and clinical utility of an ultra performance liquid chromatography − tandem mass spectrometry assay for monitoring omadacycline and tigecycline in severe bacterial infections Method validation of an inductively coupled plasma mass spectrometry (ICP-MS) assay for the analysis of magnesium, copper and zinc in red blood cells Liquid chromatography-mass spectrometric method for the simultaneous analysis of branched-chain amino acids and their ketoacids from dried blood spot as secondary analytes for the detection of maple syrup urine disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1