Javier Castañeda, Arcelia Arrieta, Tim van den Heuvel, Tadej Battelino, Ohad Cohen
{"title":"1 型糖尿病患者血糖控制在严格范围内的时间:MiniMed 780G 系统实际用户的预测因素和可实现目标","authors":"Javier Castañeda, Arcelia Arrieta, Tim van den Heuvel, Tadej Battelino, Ohad Cohen","doi":"10.2337/dc23-1581","DOIUrl":null,"url":null,"abstract":"OBJECTIVE We studied time in tight range (TITR; 70–140 mg/dL) in real-world users of the MiniMed 780G system (MM780G). RESEARCH DESIGN AND METHODS CareLink Personal data were extracted (August 2020 to December 2022) to examine TITR and its relationship with time in range (TIR; 70–180 mg/dL), factors predicting higher TITR, and which TITR target is a reasonable treatment goal. RESULTS The 13,461 users (3,762 age ≤15 years and 9,699 age >15 years) showed an average TITR of 48.9% in those age ≤15 years and 48.8% in the older group (vs. TIR 71.2% and 73.9%, respectively). Consistent use of a glucose target (GT) of 100 mg/dL and active insulin time (AIT) of 2 h were the most relevant factors predicting higher TITR (P < 0.0001). In users consistently applying these optimal settings, TITR was 56.7% in those age ≤15 years and 57.0% in the older group, and the relative impact of these settings on TITR was 60% and 86% greater than that on TIR, respectively. TITRs of ∼45% (age ≤15 years 46.3% and older group 45.4%), ∼50% (50.7% and 50.7%) and ∼55% (56.4% and 58.0%) were best associated with glucose management indicators <7.0%, <6.8%, and <6.5%, respectively. TITRs of >45%, >50%, and >55% were achieved in 91%, 74%, and 55% of those age ≤15 years and 93%, 81%, and 57% of older group users, respectively, at optimal settings. CONCLUSIONS This study demonstrates that 1) mean TIR is high with a high mean TITR in MM780G users (>48%), 2) consistent use of optimal GT/AIT improves TITR (>56%), 3) the impact of these settings on TITR is larger than on TIR, and 4) a TITR target >50% is our suggested treatment goal.","PeriodicalId":11140,"journal":{"name":"Diabetes Care","volume":null,"pages":null},"PeriodicalIF":14.8000,"publicationDate":"2023-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Time in Tight Glucose Range in Type 1 Diabetes: Predictive Factors and Achievable Targets in Real-World Users of the MiniMed 780G System\",\"authors\":\"Javier Castañeda, Arcelia Arrieta, Tim van den Heuvel, Tadej Battelino, Ohad Cohen\",\"doi\":\"10.2337/dc23-1581\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVE We studied time in tight range (TITR; 70–140 mg/dL) in real-world users of the MiniMed 780G system (MM780G). RESEARCH DESIGN AND METHODS CareLink Personal data were extracted (August 2020 to December 2022) to examine TITR and its relationship with time in range (TIR; 70–180 mg/dL), factors predicting higher TITR, and which TITR target is a reasonable treatment goal. RESULTS The 13,461 users (3,762 age ≤15 years and 9,699 age >15 years) showed an average TITR of 48.9% in those age ≤15 years and 48.8% in the older group (vs. TIR 71.2% and 73.9%, respectively). Consistent use of a glucose target (GT) of 100 mg/dL and active insulin time (AIT) of 2 h were the most relevant factors predicting higher TITR (P < 0.0001). In users consistently applying these optimal settings, TITR was 56.7% in those age ≤15 years and 57.0% in the older group, and the relative impact of these settings on TITR was 60% and 86% greater than that on TIR, respectively. TITRs of ∼45% (age ≤15 years 46.3% and older group 45.4%), ∼50% (50.7% and 50.7%) and ∼55% (56.4% and 58.0%) were best associated with glucose management indicators <7.0%, <6.8%, and <6.5%, respectively. TITRs of >45%, >50%, and >55% were achieved in 91%, 74%, and 55% of those age ≤15 years and 93%, 81%, and 57% of older group users, respectively, at optimal settings. CONCLUSIONS This study demonstrates that 1) mean TIR is high with a high mean TITR in MM780G users (>48%), 2) consistent use of optimal GT/AIT improves TITR (>56%), 3) the impact of these settings on TITR is larger than on TIR, and 4) a TITR target >50% is our suggested treatment goal.\",\"PeriodicalId\":11140,\"journal\":{\"name\":\"Diabetes Care\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":14.8000,\"publicationDate\":\"2023-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetes Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2337/dc23-1581\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2337/dc23-1581","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
Time in Tight Glucose Range in Type 1 Diabetes: Predictive Factors and Achievable Targets in Real-World Users of the MiniMed 780G System
OBJECTIVE We studied time in tight range (TITR; 70–140 mg/dL) in real-world users of the MiniMed 780G system (MM780G). RESEARCH DESIGN AND METHODS CareLink Personal data were extracted (August 2020 to December 2022) to examine TITR and its relationship with time in range (TIR; 70–180 mg/dL), factors predicting higher TITR, and which TITR target is a reasonable treatment goal. RESULTS The 13,461 users (3,762 age ≤15 years and 9,699 age >15 years) showed an average TITR of 48.9% in those age ≤15 years and 48.8% in the older group (vs. TIR 71.2% and 73.9%, respectively). Consistent use of a glucose target (GT) of 100 mg/dL and active insulin time (AIT) of 2 h were the most relevant factors predicting higher TITR (P < 0.0001). In users consistently applying these optimal settings, TITR was 56.7% in those age ≤15 years and 57.0% in the older group, and the relative impact of these settings on TITR was 60% and 86% greater than that on TIR, respectively. TITRs of ∼45% (age ≤15 years 46.3% and older group 45.4%), ∼50% (50.7% and 50.7%) and ∼55% (56.4% and 58.0%) were best associated with glucose management indicators <7.0%, <6.8%, and <6.5%, respectively. TITRs of >45%, >50%, and >55% were achieved in 91%, 74%, and 55% of those age ≤15 years and 93%, 81%, and 57% of older group users, respectively, at optimal settings. CONCLUSIONS This study demonstrates that 1) mean TIR is high with a high mean TITR in MM780G users (>48%), 2) consistent use of optimal GT/AIT improves TITR (>56%), 3) the impact of these settings on TITR is larger than on TIR, and 4) a TITR target >50% is our suggested treatment goal.
期刊介绍:
The journal's overarching mission can be captured by the simple word "Care," reflecting its commitment to enhancing patient well-being. Diabetes Care aims to support better patient care by addressing the comprehensive needs of healthcare professionals dedicated to managing diabetes.
Diabetes Care serves as a valuable resource for healthcare practitioners, aiming to advance knowledge, foster research, and improve diabetes management. The journal publishes original research across various categories, including Clinical Care, Education, Nutrition, Psychosocial Research, Epidemiology, Health Services Research, Emerging Treatments and Technologies, Pathophysiology, Complications, and Cardiovascular and Metabolic Risk. Additionally, Diabetes Care features ADA statements, consensus reports, review articles, letters to the editor, and health/medical news, appealing to a diverse audience of physicians, researchers, psychologists, educators, and other healthcare professionals.