[多孔过滤净化-超高效液相色谱-串联质谱法测定中华绒螯蟹中的 14 种全氟烷基物质]。

IF 1.2 4区 化学 Q4 CHEMISTRY, ANALYTICAL 色谱 Pub Date : 2023-12-01 DOI:10.3724/SP.J.1123.2023.07017
Xianli Wang, Qinxiong Rao, Qicai Zhang, Penghui DU, Weiguo Song
{"title":"[多孔过滤净化-超高效液相色谱-串联质谱法测定中华绒螯蟹中的 14 种全氟烷基物质]。","authors":"Xianli Wang, Qinxiong Rao, Qicai Zhang, Penghui DU, Weiguo Song","doi":"10.3724/SP.J.1123.2023.07017","DOIUrl":null,"url":null,"abstract":"<p><p>Perfluoroalkyl substances (PFASs) have become a new food-safety problem. Dietary intake is a major pathway of human exposure to PFASs. Chinese mitten crab (<i>Eriocheir sinensis</i>) is a high-end aquaculture product popular among consumers in China. Conventional extraction methods for PFASs are cumbersome and time consuming, and result in incomplete purification; thus, this technique does not meet the requirements for PFAS detection. Herein, an analytical strategy was established for the rapid detection of 14 PFASs in Chinese mitten crab based on multi-plug filtration cleanup (m-PFC) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The carbon-chain length of the 14 PFASs analyzed in this study ranged from 4 to 14, and they are perfluorobutanoic acid (PFBA), perfluoro-<i>n</i>-pentanoic acid (PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnDA), perfluorododecanoic acid (PFDoDA), perfluorotetradecanoic acid (PFTeDA), perfluoro-1-butane sulfonic acid (PFBS), perfluoro-1-hexane sulfonic acid (PFHxS), perfluoro-1-octane sulfonic acid (PFOS), and perfluoro-1-decanesulfonate (PFDS). The m-PFC column was prepared using carboxy-based multiwalled carbon nanotubes, and used to reduce the interference of sample impurities. The samples were extracted with 5 mL of 0.1% formic acid aqueous solution, 15 mL of acetonitrile and extraction salt (2 g Na<sub>2</sub>SO<sub>4</sub> and 2 g NaCl). The supernatant (10 mL) was purified using the m-PFC column, concentrated to near dryness under nitrogen, and then redissolved in 1 mL of methanol. Finally, the sample solution was filtered through a 0.22 μm polypropylene syringe filter for UPLC-MS/MS analysis. The target analytes were separated using a Shimadzu Shim-pack G1ST-C18 chromatographic column (100 mm×2.1 mm, 2 μm) using methanol (A) and 5 mmol/L ammonium acetate aqueous solution (B) as the mobile phases via gradient elution. The linear gradient program were as follows: 0-0.5 min, 10%A-35%A; 0.5-3 min, 35%A-60%A; 3-5 min, 60%A-100%A; 5-6.5 min, 100%A; 6.5-7 min, 100%A-10%A. The target analytes were analyzed using negative electrospray ionization in multiple-reaction monitoring mode, and quantitative analysis was performed using the internal standard method. In this study, we optimized the mobile-phase system as well as the extraction solvent, time, volume, and salt. The 14 PFASs exhibited good peak shapes and sensitivities when the 5 mmol/L ammonium acetate solution-methanol system was used as the mobile phase. Compared with acetonitrile or methanol alone, the extraction efficiencies of the 14 PFASs were significantly improved when 5 mL of 0.1% formic acid aqueous solution was added, followed by 15 mL of acetonitrile. The extraction efficiencies of the 14 PFASs did not differ significantly when the extraction time was within 3-15 min. The extraction salt (MgSO<sub>4</sub>, Na<sub>2</sub>SO<sub>4</sub>, NaCl, (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub>, and Na<sub>2</sub>SO<sub>4</sub>+NaCl) significantly affected the extraction efficiencies of the 14 PFASs. The highest extraction efficiencies of the 14 PFASs, which ranged from 47.9% to 121.9%, were obtained when Na<sub>2</sub>SO<sub>4</sub>+NaCl was used as the extraction salt. Under the optimal experimental conditions, good linearities (<i>R</i><sup>2</sup>=0.998-0.999) were obtained for seven PFASs (PFBS, PFHxA, PFHpA, PFHxS, PFDA, PFDoDA, PFTeDA) at 0.10-100 μg/L, and seven PFASs (PFBA, PFPeA, PFOA, PFOS, PFNA, PFUnDA, PFDS) at 0.50-100 μg/L. The average spiked recoveries for the 14 PFASs in Chinese mitten crabs at three levels ranged from 73.1% to 120%, with relative standard deviations (RSDs) in the range of 1.68%-19.5%(<i>n</i>=6). The limits of detection (LODs) and quantification (LOQs) of the 14 PFASs were in the range of 0.03-0.15 and 0.10-0.50 μg/kg, respectively. The developed method was applied to the analysis of crab samples collected from three farms in Shanghai, and PFASs with total concentrations of 3.52-37.77 μg/kg were detected in all samples. The detection frequencies for PFDA, PFUnDA, PFDoDA, PFTeDA, and PFOS were 100%. PFDA, PFUnDA, PFOS, and PFDoDA were the most abundant congeners, accounting for 31.2%, 30.6%, 15.0%, and 10.9%, respectively, of the 14 PFASs detected. The proposed method is simple, efficient, accurate, and suitable for the rapid analysis of 14 PFASs in Chinese mitten crabs.</p>","PeriodicalId":9864,"journal":{"name":"色谱","volume":"41 12","pages":"1095-1105"},"PeriodicalIF":1.2000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10719808/pdf/","citationCount":"0","resultStr":"{\"title\":\"[Determination of 14 perfluoroalkyl substances in Chinese mitten crab by multi-plug filtration cleanup coupled with ultra-performance liquid chromatography-tandem mass spectrometry].\",\"authors\":\"Xianli Wang, Qinxiong Rao, Qicai Zhang, Penghui DU, Weiguo Song\",\"doi\":\"10.3724/SP.J.1123.2023.07017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Perfluoroalkyl substances (PFASs) have become a new food-safety problem. Dietary intake is a major pathway of human exposure to PFASs. Chinese mitten crab (<i>Eriocheir sinensis</i>) is a high-end aquaculture product popular among consumers in China. Conventional extraction methods for PFASs are cumbersome and time consuming, and result in incomplete purification; thus, this technique does not meet the requirements for PFAS detection. Herein, an analytical strategy was established for the rapid detection of 14 PFASs in Chinese mitten crab based on multi-plug filtration cleanup (m-PFC) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The carbon-chain length of the 14 PFASs analyzed in this study ranged from 4 to 14, and they are perfluorobutanoic acid (PFBA), perfluoro-<i>n</i>-pentanoic acid (PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnDA), perfluorododecanoic acid (PFDoDA), perfluorotetradecanoic acid (PFTeDA), perfluoro-1-butane sulfonic acid (PFBS), perfluoro-1-hexane sulfonic acid (PFHxS), perfluoro-1-octane sulfonic acid (PFOS), and perfluoro-1-decanesulfonate (PFDS). The m-PFC column was prepared using carboxy-based multiwalled carbon nanotubes, and used to reduce the interference of sample impurities. The samples were extracted with 5 mL of 0.1% formic acid aqueous solution, 15 mL of acetonitrile and extraction salt (2 g Na<sub>2</sub>SO<sub>4</sub> and 2 g NaCl). The supernatant (10 mL) was purified using the m-PFC column, concentrated to near dryness under nitrogen, and then redissolved in 1 mL of methanol. Finally, the sample solution was filtered through a 0.22 μm polypropylene syringe filter for UPLC-MS/MS analysis. The target analytes were separated using a Shimadzu Shim-pack G1ST-C18 chromatographic column (100 mm×2.1 mm, 2 μm) using methanol (A) and 5 mmol/L ammonium acetate aqueous solution (B) as the mobile phases via gradient elution. The linear gradient program were as follows: 0-0.5 min, 10%A-35%A; 0.5-3 min, 35%A-60%A; 3-5 min, 60%A-100%A; 5-6.5 min, 100%A; 6.5-7 min, 100%A-10%A. The target analytes were analyzed using negative electrospray ionization in multiple-reaction monitoring mode, and quantitative analysis was performed using the internal standard method. In this study, we optimized the mobile-phase system as well as the extraction solvent, time, volume, and salt. The 14 PFASs exhibited good peak shapes and sensitivities when the 5 mmol/L ammonium acetate solution-methanol system was used as the mobile phase. Compared with acetonitrile or methanol alone, the extraction efficiencies of the 14 PFASs were significantly improved when 5 mL of 0.1% formic acid aqueous solution was added, followed by 15 mL of acetonitrile. The extraction efficiencies of the 14 PFASs did not differ significantly when the extraction time was within 3-15 min. The extraction salt (MgSO<sub>4</sub>, Na<sub>2</sub>SO<sub>4</sub>, NaCl, (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub>, and Na<sub>2</sub>SO<sub>4</sub>+NaCl) significantly affected the extraction efficiencies of the 14 PFASs. The highest extraction efficiencies of the 14 PFASs, which ranged from 47.9% to 121.9%, were obtained when Na<sub>2</sub>SO<sub>4</sub>+NaCl was used as the extraction salt. Under the optimal experimental conditions, good linearities (<i>R</i><sup>2</sup>=0.998-0.999) were obtained for seven PFASs (PFBS, PFHxA, PFHpA, PFHxS, PFDA, PFDoDA, PFTeDA) at 0.10-100 μg/L, and seven PFASs (PFBA, PFPeA, PFOA, PFOS, PFNA, PFUnDA, PFDS) at 0.50-100 μg/L. The average spiked recoveries for the 14 PFASs in Chinese mitten crabs at three levels ranged from 73.1% to 120%, with relative standard deviations (RSDs) in the range of 1.68%-19.5%(<i>n</i>=6). The limits of detection (LODs) and quantification (LOQs) of the 14 PFASs were in the range of 0.03-0.15 and 0.10-0.50 μg/kg, respectively. The developed method was applied to the analysis of crab samples collected from three farms in Shanghai, and PFASs with total concentrations of 3.52-37.77 μg/kg were detected in all samples. The detection frequencies for PFDA, PFUnDA, PFDoDA, PFTeDA, and PFOS were 100%. PFDA, PFUnDA, PFOS, and PFDoDA were the most abundant congeners, accounting for 31.2%, 30.6%, 15.0%, and 10.9%, respectively, of the 14 PFASs detected. The proposed method is simple, efficient, accurate, and suitable for the rapid analysis of 14 PFASs in Chinese mitten crabs.</p>\",\"PeriodicalId\":9864,\"journal\":{\"name\":\"色谱\",\"volume\":\"41 12\",\"pages\":\"1095-1105\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10719808/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"色谱\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.3724/SP.J.1123.2023.07017\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"色谱","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2023.07017","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

全氟烷基物质(PFAS)已成为一个新的食品安全问题。膳食摄入是人类接触 PFASs 的主要途径。中华绒螯蟹(Eriocheir sinensis)是深受中国消费者喜爱的高端水产品。传统的全氟辛烷磺酸萃取方法繁琐耗时,且净化不彻底,无法满足全氟辛烷磺酸检测的要求。本文建立了基于多孔滤芯过滤净化(m-PFC)和超高效液相色谱-串联质谱(UPLC-MS/MS)快速检测中华绒螯蟹中14种PFAS的分析策略。本研究分析的14种PFAS的碳链长度在4至14之间,分别为全氟丁酸(PFBA)、全氟正戊酸(PFPeA)、全氟己酸(PFHxA)、全氟庚酸(PFHpA)、全氟辛酸(PFOA)、全氟壬酸(PFNA)、全氟癸酸 (PFDA)、全氟十一烷酸 (PFUnDA)、全氟十二烷酸 (PFDoDA)、全氟十四烷酸 (PFTeDA)、全氟-1-丁烷磺酸 (PFBS)、全氟-1-己烷磺酸 (PFHxS)、全氟-1-辛烷磺酸 (PFOS) 和全氟-1-癸烷磺酸 (PFDS)。m-PFC 色谱柱采用羧基多壁碳纳米管制备,用于减少样品杂质的干扰。样品用 5 mL 0.1% 甲酸水溶液、15 mL 乙腈和提取盐(2 g Na2SO4 和 2 g NaCl)提取。上清液(10 mL)使用 m-PFC 柱纯化,在氮气下浓缩至接近干燥,然后重新溶解在 1 mL 甲醇中。最后,样品溶液经 0.22 μm 聚丙烯注射器过滤器过滤,用于 UPLC-MS/MS 分析。使用岛津 Shim-pack G1ST-C18 色谱柱(100 mm×2.1 mm,2 μm),以甲醇(A)和 5 mmol/L 乙酸铵水溶液(B)为流动相,通过梯度洗脱分离目标分析物。线性梯度程序如下0-0.5 分钟,10%A-35%A;0.5-3 分钟,35%A-60%A;3-5 分钟,60%A-100%A;5-6.5 分钟,100%A;6.5-7 分钟,100%A-10%A。目标分析物在多重反应监测模式下采用负电喷雾电离进行分析,并采用内标法进行定量分析。本研究对流动相系统以及萃取溶剂、时间、体积和盐进行了优化。以 5 mmol/L 醋酸铵溶液-甲醇体系为流动相时,14 种 PFAS 具有良好的峰形和灵敏度。与单独使用乙腈或甲醇相比,在加入 5 mL 0.1% 甲酸水溶液后再加入 15 mL 乙腈,14 种 PFAS 的萃取效率明显提高。当萃取时间在 3-15 分钟内时,14 种 PFAS 的萃取效率没有明显差异。萃取盐(MgSO4、Na2SO4、NaCl、(NH4)2SO4 和 Na2SO4+NaCl)对 14 种 PFAS 的萃取效率有显著影响。以Na2SO4+NaCl为萃取盐时,14种全氟辛烷磺酸的萃取效率最高,从47.9%到121.9%不等。在最佳实验条件下,7种PFASs(PFBS、PFHxA、PFHpA、PFHxS、PFDA、PFDoDA、PFTeDA)在0.10-100 μg/L、7种PFASs(PFBA、PFPeA、PFOA、PFOS、PFNA、PFUnDA、PFDS)在0.50-100 μg/L的线性关系良好(R2=0.998-0.999)。在3个添加水平下,中华绒螯蟹中14种PFASs的平均加标回收率为73.1%~120%,相对标准偏差为1.68%~19.5%(n=6)。14种全氟辛烷磺酸的检出限(LOD)和定量限(LOQ)分别为0.03~0.15 μg/kg和0.10~0.50 μg/kg。将所建立的方法应用于分析从上海三个养殖场采集的螃蟹样品,所有样品均检出PFASs,总浓度为3.52-37.77 μg/kg。PFDA、PFUnDA、PFDoDA、PFTeDA 和 PFOS 的检出率均为 100%。在检测到的 14 种 PFAS 中,PFDA、PFUnDA、PFOS 和 PFDoDA 的含量最高,分别占 31.2%、30.6%、15.0% 和 10.9%。该方法简便、高效、准确,适用于中华绒螯蟹中14种PFASs的快速分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Determination of 14 perfluoroalkyl substances in Chinese mitten crab by multi-plug filtration cleanup coupled with ultra-performance liquid chromatography-tandem mass spectrometry].

Perfluoroalkyl substances (PFASs) have become a new food-safety problem. Dietary intake is a major pathway of human exposure to PFASs. Chinese mitten crab (Eriocheir sinensis) is a high-end aquaculture product popular among consumers in China. Conventional extraction methods for PFASs are cumbersome and time consuming, and result in incomplete purification; thus, this technique does not meet the requirements for PFAS detection. Herein, an analytical strategy was established for the rapid detection of 14 PFASs in Chinese mitten crab based on multi-plug filtration cleanup (m-PFC) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The carbon-chain length of the 14 PFASs analyzed in this study ranged from 4 to 14, and they are perfluorobutanoic acid (PFBA), perfluoro-n-pentanoic acid (PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnDA), perfluorododecanoic acid (PFDoDA), perfluorotetradecanoic acid (PFTeDA), perfluoro-1-butane sulfonic acid (PFBS), perfluoro-1-hexane sulfonic acid (PFHxS), perfluoro-1-octane sulfonic acid (PFOS), and perfluoro-1-decanesulfonate (PFDS). The m-PFC column was prepared using carboxy-based multiwalled carbon nanotubes, and used to reduce the interference of sample impurities. The samples were extracted with 5 mL of 0.1% formic acid aqueous solution, 15 mL of acetonitrile and extraction salt (2 g Na2SO4 and 2 g NaCl). The supernatant (10 mL) was purified using the m-PFC column, concentrated to near dryness under nitrogen, and then redissolved in 1 mL of methanol. Finally, the sample solution was filtered through a 0.22 μm polypropylene syringe filter for UPLC-MS/MS analysis. The target analytes were separated using a Shimadzu Shim-pack G1ST-C18 chromatographic column (100 mm×2.1 mm, 2 μm) using methanol (A) and 5 mmol/L ammonium acetate aqueous solution (B) as the mobile phases via gradient elution. The linear gradient program were as follows: 0-0.5 min, 10%A-35%A; 0.5-3 min, 35%A-60%A; 3-5 min, 60%A-100%A; 5-6.5 min, 100%A; 6.5-7 min, 100%A-10%A. The target analytes were analyzed using negative electrospray ionization in multiple-reaction monitoring mode, and quantitative analysis was performed using the internal standard method. In this study, we optimized the mobile-phase system as well as the extraction solvent, time, volume, and salt. The 14 PFASs exhibited good peak shapes and sensitivities when the 5 mmol/L ammonium acetate solution-methanol system was used as the mobile phase. Compared with acetonitrile or methanol alone, the extraction efficiencies of the 14 PFASs were significantly improved when 5 mL of 0.1% formic acid aqueous solution was added, followed by 15 mL of acetonitrile. The extraction efficiencies of the 14 PFASs did not differ significantly when the extraction time was within 3-15 min. The extraction salt (MgSO4, Na2SO4, NaCl, (NH4)2SO4, and Na2SO4+NaCl) significantly affected the extraction efficiencies of the 14 PFASs. The highest extraction efficiencies of the 14 PFASs, which ranged from 47.9% to 121.9%, were obtained when Na2SO4+NaCl was used as the extraction salt. Under the optimal experimental conditions, good linearities (R2=0.998-0.999) were obtained for seven PFASs (PFBS, PFHxA, PFHpA, PFHxS, PFDA, PFDoDA, PFTeDA) at 0.10-100 μg/L, and seven PFASs (PFBA, PFPeA, PFOA, PFOS, PFNA, PFUnDA, PFDS) at 0.50-100 μg/L. The average spiked recoveries for the 14 PFASs in Chinese mitten crabs at three levels ranged from 73.1% to 120%, with relative standard deviations (RSDs) in the range of 1.68%-19.5%(n=6). The limits of detection (LODs) and quantification (LOQs) of the 14 PFASs were in the range of 0.03-0.15 and 0.10-0.50 μg/kg, respectively. The developed method was applied to the analysis of crab samples collected from three farms in Shanghai, and PFASs with total concentrations of 3.52-37.77 μg/kg were detected in all samples. The detection frequencies for PFDA, PFUnDA, PFDoDA, PFTeDA, and PFOS were 100%. PFDA, PFUnDA, PFOS, and PFDoDA were the most abundant congeners, accounting for 31.2%, 30.6%, 15.0%, and 10.9%, respectively, of the 14 PFASs detected. The proposed method is simple, efficient, accurate, and suitable for the rapid analysis of 14 PFASs in Chinese mitten crabs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
色谱
色谱 CHEMISTRY, ANALYTICAL-
CiteScore
1.30
自引率
42.90%
发文量
7198
期刊介绍: "Chinese Journal of Chromatography" mainly reports the basic research results of chromatography, important application results of chromatography and its interdisciplinary subjects and their progress, including the application of new methods, new technologies, and new instruments in various fields, the research and development of chromatography instruments and components, instrument analysis teaching research, etc. It is suitable for researchers engaged in chromatography basic and application technology research in scientific research institutes, master and doctoral students in chromatography and related disciplines, grassroots researchers in the field of analysis and testing, and relevant personnel in chromatography instrument development and operation units. The journal has columns such as special planning, focus, perspective, research express, research paper, monograph and review, micro review, technology and application, and teaching research.
期刊最新文献
[Off-line comprehensive two-dimensional countercurrent chromatography-liquid chromatography separation of Curcuma volatile oil]. [Advances in synthesis methods and applications of microporous organic networks for sample preparation]. [Application progress of on-line sample preparation techniques coupled with liquid chromatography-mass spectrometry system in the detection of food hazards]. [Chiral capillary gas chromatography for the separation of the enantiomers of 4-chloromethyl-2,2-dimethyl-1,3-dioxolane]. [Determination of 14 β-agonists in animal meat by ultra high performance liquid chromatography-tandem mass spectrometry].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1