{"title":"机器人辅助全膝关节置换术技术为评估软组织平衡提供了一种可重复、可再现的方法。","authors":"Laura Y Scholl, Emily L Hampp, Melanie Caba, Ali Azhar, Daniel Hameed, Jeremy Dubin, James P Crutcher, Michael A Mont, Ormonde M Mahoney","doi":"10.1055/a-2232-7511","DOIUrl":null,"url":null,"abstract":"<p><p>Soft-tissue balancing is an important factor in primary total knee arthroplasty (TKA), with 30 to 50% of TKA revisions attributed to technical operative factors including soft-tissue balancing. Robotic-assisted TKA (RATKA) offers opportunities for improved soft-tissue balancing methods. This study aimed to evaluate the repeatability and reproducibility of ligamentous laxity assessments during RATKA using a digital tensioner.Three experienced RATKA surgeons assessed preresection and trialing phases of 12 human cadaveric knees with varying degrees of arthritis. Ligamentous laxity was assessed with manual varus and valgus stresses in extension and flexion, with a digital tensioner providing feedback on the change of laxity displacement. Intraclass correlation coefficient (ICC) analyses were used to determine the repeatability within a single surgeon and reproducibility between the three surgeons.The results showed excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA. Surgeons had excellent repeatability for preresection and trialing assessments, with median ICC values representing excellent reproducibility between surgeons. Surgeons were repeatable within 1 or 1.5 mm for preresection and trialing assessments. On average, the variation within a surgeon was 0.33 ± 0.26 mm during preresection and 0.29 ± 0.28 mm during trialing. When comparing surgeons to each other, they were reproducible within an average of 0.69 ± 0.33 mm for preresection and 0.65 ± 0.31 mm for trialing.This study demonstrated the reliability of robotic-assisted soft-tissue balancing techniques, providing control over ligamentous laxity assessments, and potentially leading to better patient outcomes. The digital tensioner used in this study provided excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA, highlighting the potential benefits of incorporating robotics in TKA procedures.</p>","PeriodicalId":48798,"journal":{"name":"Journal of Knee Surgery","volume":" ","pages":"607-611"},"PeriodicalIF":1.6000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Robotic-assisted Total Knee Arthroplasty Technology Provides a Repeatable and Reproducible Method of Assessing Soft Tissue Balance.\",\"authors\":\"Laura Y Scholl, Emily L Hampp, Melanie Caba, Ali Azhar, Daniel Hameed, Jeremy Dubin, James P Crutcher, Michael A Mont, Ormonde M Mahoney\",\"doi\":\"10.1055/a-2232-7511\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Soft-tissue balancing is an important factor in primary total knee arthroplasty (TKA), with 30 to 50% of TKA revisions attributed to technical operative factors including soft-tissue balancing. Robotic-assisted TKA (RATKA) offers opportunities for improved soft-tissue balancing methods. This study aimed to evaluate the repeatability and reproducibility of ligamentous laxity assessments during RATKA using a digital tensioner.Three experienced RATKA surgeons assessed preresection and trialing phases of 12 human cadaveric knees with varying degrees of arthritis. Ligamentous laxity was assessed with manual varus and valgus stresses in extension and flexion, with a digital tensioner providing feedback on the change of laxity displacement. Intraclass correlation coefficient (ICC) analyses were used to determine the repeatability within a single surgeon and reproducibility between the three surgeons.The results showed excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA. Surgeons had excellent repeatability for preresection and trialing assessments, with median ICC values representing excellent reproducibility between surgeons. Surgeons were repeatable within 1 or 1.5 mm for preresection and trialing assessments. On average, the variation within a surgeon was 0.33 ± 0.26 mm during preresection and 0.29 ± 0.28 mm during trialing. When comparing surgeons to each other, they were reproducible within an average of 0.69 ± 0.33 mm for preresection and 0.65 ± 0.31 mm for trialing.This study demonstrated the reliability of robotic-assisted soft-tissue balancing techniques, providing control over ligamentous laxity assessments, and potentially leading to better patient outcomes. The digital tensioner used in this study provided excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA, highlighting the potential benefits of incorporating robotics in TKA procedures.</p>\",\"PeriodicalId\":48798,\"journal\":{\"name\":\"Journal of Knee Surgery\",\"volume\":\" \",\"pages\":\"607-611\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Knee Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2232-7511\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Knee Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2232-7511","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

导言:软组织平衡是初级全膝关节置换术(TKA)中的一个重要因素,30%至 50%的 TKA 修 复归因于包括软组织平衡在内的技术操作因素。机器人辅助全膝关节置换术(RATKA)为改进软组织平衡方法提供了机会。本研究旨在评估在 RATKA 过程中使用数字拉力器进行韧带松弛评估的可重复性和再现性:方法:三位经验丰富的 RATKA 外科医生评估了 12 个患有不同程度关节炎的人体尸体膝关节的切除前和试验阶段。韧带松弛度通过伸展和屈曲时的手动变位和外翻应力进行评估,数字拉力器对松弛位移的变化提供反馈。使用类内相关系数(ICC)分析来确定单个外科医生的重复性和三个外科医生之间的再现性:结果:结果显示,RATKA术中韧带松弛评估的重复性和再现性极佳。外科医生在切除前和试验评估中的重复性极佳,中位 ICC 值代表了外科医生之间极佳的重复性。外科医生对切除前和试验评估的重复性在 1 毫米或 1.5 毫米以内。平均而言,每名外科医生在解剖前评估中的误差为 0.33 毫米 ± 0.26 毫米,在试验中的误差为 0.29 毫米 ± 0.28 毫米。当外科医生之间进行比较时,他们的重复性平均在0.69毫米±0.33毫米(解剖前)和0.65毫米±0.31毫米(试运行)之间:这项研究证明了机器人辅助软组织平衡技术的可靠性,为韧带松弛评估提供了控制,并有可能为患者带来更好的治疗效果。本研究中使用的数字拉力器在RATKA过程中的韧带松弛评估中提供了极佳的可重复性和再现性,凸显了将机器人技术应用于TKA手术的潜在优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Robotic-assisted Total Knee Arthroplasty Technology Provides a Repeatable and Reproducible Method of Assessing Soft Tissue Balance.

Soft-tissue balancing is an important factor in primary total knee arthroplasty (TKA), with 30 to 50% of TKA revisions attributed to technical operative factors including soft-tissue balancing. Robotic-assisted TKA (RATKA) offers opportunities for improved soft-tissue balancing methods. This study aimed to evaluate the repeatability and reproducibility of ligamentous laxity assessments during RATKA using a digital tensioner.Three experienced RATKA surgeons assessed preresection and trialing phases of 12 human cadaveric knees with varying degrees of arthritis. Ligamentous laxity was assessed with manual varus and valgus stresses in extension and flexion, with a digital tensioner providing feedback on the change of laxity displacement. Intraclass correlation coefficient (ICC) analyses were used to determine the repeatability within a single surgeon and reproducibility between the three surgeons.The results showed excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA. Surgeons had excellent repeatability for preresection and trialing assessments, with median ICC values representing excellent reproducibility between surgeons. Surgeons were repeatable within 1 or 1.5 mm for preresection and trialing assessments. On average, the variation within a surgeon was 0.33 ± 0.26 mm during preresection and 0.29 ± 0.28 mm during trialing. When comparing surgeons to each other, they were reproducible within an average of 0.69 ± 0.33 mm for preresection and 0.65 ± 0.31 mm for trialing.This study demonstrated the reliability of robotic-assisted soft-tissue balancing techniques, providing control over ligamentous laxity assessments, and potentially leading to better patient outcomes. The digital tensioner used in this study provided excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA, highlighting the potential benefits of incorporating robotics in TKA procedures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
5.90%
发文量
139
期刊介绍: The Journal of Knee Surgery covers a range of issues relating to the orthopaedic techniques of arthroscopy, arthroplasty, and reconstructive surgery of the knee joint. In addition to original peer-review articles, this periodical provides details on emerging surgical techniques, as well as reviews and special focus sections. Topics of interest include cruciate ligament repair and reconstruction, bone grafting, cartilage regeneration, and magnetic resonance imaging.
期刊最新文献
Articular Cartilage Damage in the Patellofemoral Compartment at ACL Reconstruction Predicts Poor Postoperative Subjective Outcomes in Patients Age 40 and Older. Survey Results Concerning Current Trends in Meniscus Repair Indications and Preferences from Members of the Pediatric Research in Sports Medicine (PRiSM) Society. Impact of Joint Laxity on 2-Year KOOS Outcomes of Posterior Stabilized Total Knee Arthroplasty. Interatrial Wall Abnormality is Associated with Adverse Same-Admission Outcomes Following Total Knee Arthroplasty. Survivorship of Primary NexGen Knee Replacement: Comparing Cementless Trabecular Metal to Other Designs of Tibial Component.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1