水泥类型、过量清除和抛光对水泥接缝的影响。

IF 1.3 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Quintessence international Pub Date : 2024-02-28 DOI:10.3290/j.qi.b4780239
Georg Beierlein, Laura Haas, Sebastian Hahnel, Michael Schmidt, Martin Rosentritt
{"title":"水泥类型、过量清除和抛光对水泥接缝的影响。","authors":"Georg Beierlein, Laura Haas, Sebastian Hahnel, Michael Schmidt, Martin Rosentritt","doi":"10.3290/j.qi.b4780239","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To compare marginal gap width and depth with different cementation systems, excess removal, and after polishing.</p><p><strong>Method and materials: </strong>In total, 80 composite crowns were milled, divided into ten groups, and cemented on identical artificial teeth. Eight crowns per group were fixed with (i) zinc phosphate cement (ZnOPh), (ii) glass-ionomer cement (GIC), (iii) resin-reinforced glass-ionomer cement (GIC mod), (iv) dual-curing adhesive composite (Comp dual), or (v) dual-curing self-adhesive composite (Comp SE dual). Excess removal was performed with a scaler after brief light-cure (tack-cure), final light-cure, during rubber or gel phase or by wiping with foam pellet. Curing was completed in chemical, dark cure, or light-curing modus. The specimens were polished and stored in water (37°C). The margins were digitized using a 3D laser-scanning microscope (VK-X100 series, Keyence). The width and the depth of the marginal gap were measured at 10 points between the crown margin and the preparation margin.</p><p><strong>Results: </strong>The width after excess removal varied between 65.1 ± 15.7 µm (Comp dual, wipe, with polishing) and 208.6 ± 266.7 µm (Comp SE dual, dark cure, without polishing). The depth varied between 29.8 ± 22.2 µm (Comp dual, wipe, with polishing) and 89.5 ± 45.2 µm (Comp SE dual, dark cure, without polishing). The impact on gap width and depth was detected for fixation material, excess removal, and polishing.</p><p><strong>Conclusion: </strong>The gap depth and width depend on the luting material and the mode of access removal. Polishing can improve the gap quality, especially for GIC and resin-based systems.</p>","PeriodicalId":20831,"journal":{"name":"Quintessence international","volume":"0 0","pages":"98-105"},"PeriodicalIF":1.3000,"publicationDate":"2024-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of cement type, excess removal, and polishing on the cement joint.\",\"authors\":\"Georg Beierlein, Laura Haas, Sebastian Hahnel, Michael Schmidt, Martin Rosentritt\",\"doi\":\"10.3290/j.qi.b4780239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To compare marginal gap width and depth with different cementation systems, excess removal, and after polishing.</p><p><strong>Method and materials: </strong>In total, 80 composite crowns were milled, divided into ten groups, and cemented on identical artificial teeth. Eight crowns per group were fixed with (i) zinc phosphate cement (ZnOPh), (ii) glass-ionomer cement (GIC), (iii) resin-reinforced glass-ionomer cement (GIC mod), (iv) dual-curing adhesive composite (Comp dual), or (v) dual-curing self-adhesive composite (Comp SE dual). Excess removal was performed with a scaler after brief light-cure (tack-cure), final light-cure, during rubber or gel phase or by wiping with foam pellet. Curing was completed in chemical, dark cure, or light-curing modus. The specimens were polished and stored in water (37°C). The margins were digitized using a 3D laser-scanning microscope (VK-X100 series, Keyence). The width and the depth of the marginal gap were measured at 10 points between the crown margin and the preparation margin.</p><p><strong>Results: </strong>The width after excess removal varied between 65.1 ± 15.7 µm (Comp dual, wipe, with polishing) and 208.6 ± 266.7 µm (Comp SE dual, dark cure, without polishing). The depth varied between 29.8 ± 22.2 µm (Comp dual, wipe, with polishing) and 89.5 ± 45.2 µm (Comp SE dual, dark cure, without polishing). The impact on gap width and depth was detected for fixation material, excess removal, and polishing.</p><p><strong>Conclusion: </strong>The gap depth and width depend on the luting material and the mode of access removal. Polishing can improve the gap quality, especially for GIC and resin-based systems.</p>\",\"PeriodicalId\":20831,\"journal\":{\"name\":\"Quintessence international\",\"volume\":\"0 0\",\"pages\":\"98-105\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Quintessence international\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.qi.b4780239\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quintessence international","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.qi.b4780239","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的比较不同粘接系统、去除多余部分和抛光后的边缘间隙宽度和深度:磨制 80 个复合牙冠,分成 10 组,粘结在相同的人工牙齿上。每组 8 个牙冠分别用 i) 磷酸锌水泥(ZnOPh)、ii) 玻璃离聚物水泥(GIC)、ii) 树脂增强玻璃离聚物水泥(GIC mod)、iv) 双固化粘接复合材料(Comp dual)或 v) 双固化自粘接复合材料(Comp SE dual)固定。在短暂光固化(粘性固化)、最终光固化、橡胶或凝胶阶段或使用泡沫颗粒擦拭后,使用去垢剂清除多余部分。固化以化学固化、暗固化或光固化方式完成。试样经抛光后保存在水中(37°C)。使用三维激光扫描显微镜(VK-X100 系列,Keyence,日本)对边缘进行数字化处理。在牙冠边缘和预备边缘之间的 10 个点测量边缘间隙的宽度和深度:去除多余部分后的宽度介于 65.1 ± 15.7 µm(双层化合物,擦拭,抛光)和 208.6 ± 266.7 µm(SE 双层化合物,深色固化,不抛光)之间。深度在 29.8 ± 22.2 微米(双组分,擦拭,抛光)和 89.5 ± 45.2 微米(SE 双组分,暗固化,不抛光)之间变化。固定材料、多余部分的去除和抛光对间隙宽度和深度有影响:结论:间隙的深度和宽度取决于衬垫材料和去除通道的方式。抛光可以改善间隙的质量,尤其是对于 GIC 和树脂基系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of cement type, excess removal, and polishing on the cement joint.

Objectives: To compare marginal gap width and depth with different cementation systems, excess removal, and after polishing.

Method and materials: In total, 80 composite crowns were milled, divided into ten groups, and cemented on identical artificial teeth. Eight crowns per group were fixed with (i) zinc phosphate cement (ZnOPh), (ii) glass-ionomer cement (GIC), (iii) resin-reinforced glass-ionomer cement (GIC mod), (iv) dual-curing adhesive composite (Comp dual), or (v) dual-curing self-adhesive composite (Comp SE dual). Excess removal was performed with a scaler after brief light-cure (tack-cure), final light-cure, during rubber or gel phase or by wiping with foam pellet. Curing was completed in chemical, dark cure, or light-curing modus. The specimens were polished and stored in water (37°C). The margins were digitized using a 3D laser-scanning microscope (VK-X100 series, Keyence). The width and the depth of the marginal gap were measured at 10 points between the crown margin and the preparation margin.

Results: The width after excess removal varied between 65.1 ± 15.7 µm (Comp dual, wipe, with polishing) and 208.6 ± 266.7 µm (Comp SE dual, dark cure, without polishing). The depth varied between 29.8 ± 22.2 µm (Comp dual, wipe, with polishing) and 89.5 ± 45.2 µm (Comp SE dual, dark cure, without polishing). The impact on gap width and depth was detected for fixation material, excess removal, and polishing.

Conclusion: The gap depth and width depend on the luting material and the mode of access removal. Polishing can improve the gap quality, especially for GIC and resin-based systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Quintessence international
Quintessence international 医学-牙科与口腔外科
CiteScore
3.30
自引率
5.30%
发文量
11
审稿时长
1 months
期刊介绍: QI has a new contemporary design but continues its time-honored tradition of serving the needs of the general practitioner with clinically relevant articles that are scientifically based. Dr Eli Eliav and his editorial board are dedicated to practitioners worldwide through the presentation of high-level research, useful clinical procedures, and educational short case reports and clinical notes. Rigorous but timely manuscript review is the first order of business in their quest to publish a high-quality selection of articles in the multiple specialties and disciplines that encompass dentistry.
期刊最新文献
Fully digital workflow involving 3D printed gingivectomy guide and 3D printed waxup to restore and reshape a congenitally missing central incisor after orthodontic treatment. Use of artificial intelligence to detect dental caries on intraoral photos. Complications and risk factors associated with zygomatic implants: retrospective analysis with 73 consecutive patients followed for 3.5 years. Computer-assisted contouring combined with bone ostectomy for dental implant placement of craniofacial fibrous dysplasia involving the right maxilla. Musculoskeletal pain is associated with poor sleep quality and increased daytime sleepiness in dental students: a cross-sectional pilot study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1