{"title":"超声弹性成像结合对比增强超声(CEUS)定量分析在鉴别乳腺结节性纤维囊性病变与浸润性乳腺导管癌中的应用价值","authors":"Jiajia Li, Yunfeng Wu, Zhaoyu Tian, Linfeng Shu, Siru Wu, Zuohui Wu","doi":"10.1177/01617346231217087","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to compare the value of ultrasound elastography combined with contrast-enhanced ultrasound (CEUS) quantitative analysis in the differentiation of nodular fibrocystic breast change (FBC) from breast invasive ductal carcinoma (BIDC). We selected 50 patients each with nodular FBC and BIDC, who were admitted to the Affiliated Hospital of Zunyi Medical University from January 2018 to December 2021. Their ultrasonic elastic images and CEUS videos were collected, their ultrasound elastography scores and the ratio of strain rate (SR) of the lesions were determined, and the exported DICOM format videos of CEUS were quantitatively analyzed using VueBox software to obtain quantitative perfusion parameters. The differences between the ultrasound elastography score and SR while comparing nodular FBC and BIDC cases were statistically significant (<i>p</i> < .05). The sensitivity, specificity, and accuracy of ultrasound elastography scores in the differential diagnoses of nodular FBC and BIDC were 74%, 88%, and 81%, respectively. Additionally, the sensitivity, specificity, and accuracy of SR in the differential diagnosis of nodular FBC and BIDC were 94%, 78%, and 86%, respectively. Statistically significant differences were observed in the CEUS quantitative perfusion parameters PE, AUC (WiAUC, WoAUC, WiWoAUC), and WiPI in both nodular FBC and BIDC according to the VueBox software (<i>p</i> < .05). The sensitivity, specificity, and accuracy of CEUS quantitative analysis in the differential diagnoses of nodular FBC and BIDC were 66%, 82%, and 74%, respectively. Using the pathological findings as the gold standard, ROC curves were established, and the area under the curve (AUC) of the CEUS quantitative analysis, elasticity score, SR, and ultrasound elastography combined with CEUS quantitative analysis were 0.731, 0.838, and 0.892, as well as 0.945, respectively. Ultrasound elasticity scoring, SR and CEUS quantitative analysis have certain application value for differentiating nodular FBC cases from BIDC; however, ultrasound elasticity imaging combined with CEUS quantitative analysis can help in improving the differential diagnostic efficacy of nodular FBC cases from BIDC.</p>","PeriodicalId":49401,"journal":{"name":"Ultrasonic Imaging","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application Value of Ultrasound Elastography Combined With Contrast-Enhanced Ultrasound (CEUS) Quantitative Analysis in Differentiation of Nodular Fibrocystic Changes of the Breast From Invasive Ductal Carcinoma.\",\"authors\":\"Jiajia Li, Yunfeng Wu, Zhaoyu Tian, Linfeng Shu, Siru Wu, Zuohui Wu\",\"doi\":\"10.1177/01617346231217087\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to compare the value of ultrasound elastography combined with contrast-enhanced ultrasound (CEUS) quantitative analysis in the differentiation of nodular fibrocystic breast change (FBC) from breast invasive ductal carcinoma (BIDC). We selected 50 patients each with nodular FBC and BIDC, who were admitted to the Affiliated Hospital of Zunyi Medical University from January 2018 to December 2021. Their ultrasonic elastic images and CEUS videos were collected, their ultrasound elastography scores and the ratio of strain rate (SR) of the lesions were determined, and the exported DICOM format videos of CEUS were quantitatively analyzed using VueBox software to obtain quantitative perfusion parameters. The differences between the ultrasound elastography score and SR while comparing nodular FBC and BIDC cases were statistically significant (<i>p</i> < .05). The sensitivity, specificity, and accuracy of ultrasound elastography scores in the differential diagnoses of nodular FBC and BIDC were 74%, 88%, and 81%, respectively. Additionally, the sensitivity, specificity, and accuracy of SR in the differential diagnosis of nodular FBC and BIDC were 94%, 78%, and 86%, respectively. Statistically significant differences were observed in the CEUS quantitative perfusion parameters PE, AUC (WiAUC, WoAUC, WiWoAUC), and WiPI in both nodular FBC and BIDC according to the VueBox software (<i>p</i> < .05). The sensitivity, specificity, and accuracy of CEUS quantitative analysis in the differential diagnoses of nodular FBC and BIDC were 66%, 82%, and 74%, respectively. Using the pathological findings as the gold standard, ROC curves were established, and the area under the curve (AUC) of the CEUS quantitative analysis, elasticity score, SR, and ultrasound elastography combined with CEUS quantitative analysis were 0.731, 0.838, and 0.892, as well as 0.945, respectively. Ultrasound elasticity scoring, SR and CEUS quantitative analysis have certain application value for differentiating nodular FBC cases from BIDC; however, ultrasound elasticity imaging combined with CEUS quantitative analysis can help in improving the differential diagnostic efficacy of nodular FBC cases from BIDC.</p>\",\"PeriodicalId\":49401,\"journal\":{\"name\":\"Ultrasonic Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasonic Imaging\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/01617346231217087\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonic Imaging","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01617346231217087","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
摘要
本研究旨在比较超声弹性成像联合对比增强超声(CEUS)定量分析在结节性乳腺纤维囊性变(FBC)与乳腺浸润性导管癌(BIDC)鉴别中的价值。我们选取了2018年1月至2021年12月遵义医学院附属医院收治的结节性FBC和BIDC患者各50例。收集其超声弹性图像和CEUS视频,测定其超声弹性成像评分和病变应变率(SR)比值,并利用VueBox软件对导出的DICOM格式CEUS视频进行定量分析,获得定量灌注参数。结节性 FBC 和 BIDC 病例的超声弹性成像评分和 SR 比较,差异有统计学意义(P P
Application Value of Ultrasound Elastography Combined With Contrast-Enhanced Ultrasound (CEUS) Quantitative Analysis in Differentiation of Nodular Fibrocystic Changes of the Breast From Invasive Ductal Carcinoma.
This study aimed to compare the value of ultrasound elastography combined with contrast-enhanced ultrasound (CEUS) quantitative analysis in the differentiation of nodular fibrocystic breast change (FBC) from breast invasive ductal carcinoma (BIDC). We selected 50 patients each with nodular FBC and BIDC, who were admitted to the Affiliated Hospital of Zunyi Medical University from January 2018 to December 2021. Their ultrasonic elastic images and CEUS videos were collected, their ultrasound elastography scores and the ratio of strain rate (SR) of the lesions were determined, and the exported DICOM format videos of CEUS were quantitatively analyzed using VueBox software to obtain quantitative perfusion parameters. The differences between the ultrasound elastography score and SR while comparing nodular FBC and BIDC cases were statistically significant (p < .05). The sensitivity, specificity, and accuracy of ultrasound elastography scores in the differential diagnoses of nodular FBC and BIDC were 74%, 88%, and 81%, respectively. Additionally, the sensitivity, specificity, and accuracy of SR in the differential diagnosis of nodular FBC and BIDC were 94%, 78%, and 86%, respectively. Statistically significant differences were observed in the CEUS quantitative perfusion parameters PE, AUC (WiAUC, WoAUC, WiWoAUC), and WiPI in both nodular FBC and BIDC according to the VueBox software (p < .05). The sensitivity, specificity, and accuracy of CEUS quantitative analysis in the differential diagnoses of nodular FBC and BIDC were 66%, 82%, and 74%, respectively. Using the pathological findings as the gold standard, ROC curves were established, and the area under the curve (AUC) of the CEUS quantitative analysis, elasticity score, SR, and ultrasound elastography combined with CEUS quantitative analysis were 0.731, 0.838, and 0.892, as well as 0.945, respectively. Ultrasound elasticity scoring, SR and CEUS quantitative analysis have certain application value for differentiating nodular FBC cases from BIDC; however, ultrasound elasticity imaging combined with CEUS quantitative analysis can help in improving the differential diagnostic efficacy of nodular FBC cases from BIDC.
期刊介绍:
Ultrasonic Imaging provides rapid publication for original and exceptional papers concerned with the development and application of ultrasonic-imaging technology. Ultrasonic Imaging publishes articles in the following areas: theoretical and experimental aspects of advanced methods and instrumentation for imaging