计算机辅助测量与人工测量在评估腕关节排列方面的比较。

Robert Sippo, Kira Huuska, Theresa Höglund, Eero Waris
{"title":"计算机辅助测量与人工测量在评估腕关节排列方面的比较。","authors":"Robert Sippo, Kira Huuska, Theresa Höglund, Eero Waris","doi":"10.1177/17531934231220637","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to compare computer-aided analysis and different methods of manual measurements in the evaluation of carpal alignment. The radioscaphoid, radiolunate, radiocapitate and radiometacarpal angles were measured on cone-beam computed tomography (CT) scans of 30 healthy wrists by automated software (Disior Ltd.) and by hand surgeons using lateral radiographs reconstructed from the CT data. Hand surgeons were either given (<i>n</i> = 6) or not given (<i>n</i> = 7) prior instructions on how to perform the measurements. Inter- and intra-observer reliability of manual measurements ranged from good to excellent (intra-class correlation coefficients [ICC] 0.77-0.99), being highest in specialists with standardized methods and in reconstructed radiographs with bone overlap digitally removed. Computer-aided software provided excellent intra-observer reliability (ICC 0.94-1.00) consistently and values that were highly comparable (mean difference range 1°-7°) with the manual measurements made in optimal settings. Computer-aided software provides an accurate and repeatable method to measure carpal alignment in CT scans, minimizing observational errors.</p>","PeriodicalId":94237,"journal":{"name":"The Journal of hand surgery, European volume","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11382436/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of computer-aided and manual measurements in the evaluation of carpal alignment.\",\"authors\":\"Robert Sippo, Kira Huuska, Theresa Höglund, Eero Waris\",\"doi\":\"10.1177/17531934231220637\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study was to compare computer-aided analysis and different methods of manual measurements in the evaluation of carpal alignment. The radioscaphoid, radiolunate, radiocapitate and radiometacarpal angles were measured on cone-beam computed tomography (CT) scans of 30 healthy wrists by automated software (Disior Ltd.) and by hand surgeons using lateral radiographs reconstructed from the CT data. Hand surgeons were either given (<i>n</i> = 6) or not given (<i>n</i> = 7) prior instructions on how to perform the measurements. Inter- and intra-observer reliability of manual measurements ranged from good to excellent (intra-class correlation coefficients [ICC] 0.77-0.99), being highest in specialists with standardized methods and in reconstructed radiographs with bone overlap digitally removed. Computer-aided software provided excellent intra-observer reliability (ICC 0.94-1.00) consistently and values that were highly comparable (mean difference range 1°-7°) with the manual measurements made in optimal settings. Computer-aided software provides an accurate and repeatable method to measure carpal alignment in CT scans, minimizing observational errors.</p>\",\"PeriodicalId\":94237,\"journal\":{\"name\":\"The Journal of hand surgery, European volume\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11382436/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of hand surgery, European volume\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/17531934231220637\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of hand surgery, European volume","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17531934231220637","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/16 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是比较计算机辅助分析和人工测量的不同方法在评估腕骨排列方面的差异。通过自动软件(Disior Ltd.)和手外科医生使用根据 CT 数据重建的侧位X光片,对 30 个健康手腕的锥形束计算机断层扫描(CT)扫描结果进行了桡骨掌角、桡骨月角、桡骨头角和桡腕角的测量。手外科医生事先获得(n = 6)或未获得(n = 7)如何进行测量的指导。人工测量的观察者间和观察者内可靠性从良好到极佳不等(类内相关系数 [ICC] 0.77-0.99),采用标准化方法的专家和用数字去除骨重叠的重建X光片的可靠性最高。计算机辅助软件在观察者内部的可靠性(ICC 0.94-1.00)一直非常出色,其数值与在最佳设置下进行的人工测量结果具有很高的可比性(平均差异范围为 1°-7°)。计算机辅助软件提供了一种精确且可重复的方法来测量 CT 扫描中的腕关节对齐情况,最大程度地减少了观察误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of computer-aided and manual measurements in the evaluation of carpal alignment.

The purpose of this study was to compare computer-aided analysis and different methods of manual measurements in the evaluation of carpal alignment. The radioscaphoid, radiolunate, radiocapitate and radiometacarpal angles were measured on cone-beam computed tomography (CT) scans of 30 healthy wrists by automated software (Disior Ltd.) and by hand surgeons using lateral radiographs reconstructed from the CT data. Hand surgeons were either given (n = 6) or not given (n = 7) prior instructions on how to perform the measurements. Inter- and intra-observer reliability of manual measurements ranged from good to excellent (intra-class correlation coefficients [ICC] 0.77-0.99), being highest in specialists with standardized methods and in reconstructed radiographs with bone overlap digitally removed. Computer-aided software provided excellent intra-observer reliability (ICC 0.94-1.00) consistently and values that were highly comparable (mean difference range 1°-7°) with the manual measurements made in optimal settings. Computer-aided software provides an accurate and repeatable method to measure carpal alignment in CT scans, minimizing observational errors.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Guideline on managing thumb ulnar collateral ligament injuries: the British Society of Surgery for the Hand Evidence for Surgical Treatment (BEST) findings and recommendations. Is the ulnar fovea sign positive only in foveal tears of the triangular fibrocartilage complex? Biomechanical analysis of cadaveric wrists before and after MOTEC wrist arthroplasty using a hexapod robot. Wrist arthrodesis in flexed position combined with proximal row carpectomy and ostectomy of the distal radius for spastic patients. Misinformation about upper extremity conditions in guidelines for clinicians.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1