颈椎头套在远端磨牙中的有效性与患者的依从性有关。

IF 2.8 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE European journal of orthodontics Pub Date : 2024-01-01 DOI:10.1093/ejo/cjad075
Sofia Gratsia, Alina Cocos, Heleni Vastardis, Demetrios Halazonetis
{"title":"颈椎头套在远端磨牙中的有效性与患者的依从性有关。","authors":"Sofia Gratsia, Alina Cocos, Heleni Vastardis, Demetrios Halazonetis","doi":"10.1093/ejo/cjad075","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The purpose of this study was to measure the effectiveness of the cervical headgear for distalizing first permanent maxillary molars in relation to hours of use.</p><p><strong>Methods: </strong>This was a one-centre, prospective, clinical study conducted at the Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece. Participants (N = 26; 17 females, 9 males) were patients with no history of orthodontic treatment, no syndromes or clefts, and Angle's Class II malocclusion, where the treatment plan included a cervical headgear. They were instructed to wear the appliance for at least 12 h per day. A TheraMon® microsensor was embedded in the headgear's strap to objectively measure wear-time. To measure tooth movement, pre- and post-treatment digital models were superimposed, using the palate as a reference area; translation and rotation were measured along three axes. Superimposition and movement measurements were made with the Viewbox 4 software.</p><p><strong>Results: </strong>Average treatment time and headgear wear were 130 days and 55 days, respectively, i.e. 10.1 h/day. During this period, distal movement averaged 1.75 mm with high variability (min 0.2 mm, max 4.5 mm). Distal tipping and rotation had an average of approximately 5 °C. Cumulative headgear wear was significantly correlated with distal movement (r2 = 0.32, P < .002), distal tipping (r2 = 0.27, P < .01), and distal rotation around the long axis of the tooth (r2 = 0.20, P < .05).</p><p><strong>Conclusion: </strong>Compliance is critical for having a successful clinical outcome. Distalization of the molar with a cervical headgear is correlated with the cumulative hours of appliance use, with hours per day being a weaker predictor.</p>","PeriodicalId":11989,"journal":{"name":"European journal of orthodontics","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cervical headgear effectiveness in distalizing molars in relation to patient compliance.\",\"authors\":\"Sofia Gratsia, Alina Cocos, Heleni Vastardis, Demetrios Halazonetis\",\"doi\":\"10.1093/ejo/cjad075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The purpose of this study was to measure the effectiveness of the cervical headgear for distalizing first permanent maxillary molars in relation to hours of use.</p><p><strong>Methods: </strong>This was a one-centre, prospective, clinical study conducted at the Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece. Participants (N = 26; 17 females, 9 males) were patients with no history of orthodontic treatment, no syndromes or clefts, and Angle's Class II malocclusion, where the treatment plan included a cervical headgear. They were instructed to wear the appliance for at least 12 h per day. A TheraMon® microsensor was embedded in the headgear's strap to objectively measure wear-time. To measure tooth movement, pre- and post-treatment digital models were superimposed, using the palate as a reference area; translation and rotation were measured along three axes. Superimposition and movement measurements were made with the Viewbox 4 software.</p><p><strong>Results: </strong>Average treatment time and headgear wear were 130 days and 55 days, respectively, i.e. 10.1 h/day. During this period, distal movement averaged 1.75 mm with high variability (min 0.2 mm, max 4.5 mm). Distal tipping and rotation had an average of approximately 5 °C. Cumulative headgear wear was significantly correlated with distal movement (r2 = 0.32, P < .002), distal tipping (r2 = 0.27, P < .01), and distal rotation around the long axis of the tooth (r2 = 0.20, P < .05).</p><p><strong>Conclusion: </strong>Compliance is critical for having a successful clinical outcome. Distalization of the molar with a cervical headgear is correlated with the cumulative hours of appliance use, with hours per day being a weaker predictor.</p>\",\"PeriodicalId\":11989,\"journal\":{\"name\":\"European journal of orthodontics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European journal of orthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ejo/cjad075\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ejo/cjad075","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究的目的是测量颈部头套对上颌第一恒磨牙远端矫治的有效性与使用时间的关系:这是一项在希腊雅典国立和卡波迪斯特里安大学牙科学院正畸学系进行的单中心、前瞻性临床研究。参与者(N = 26;17 名女性,9 名男性)均为无正畸治疗史、无综合症或裂隙、Angle's II 类错牙合畸形的患者,治疗方案包括颈部头套。他们被要求每天佩戴矫治器至少 12 小时。TheraMon®微型传感器被嵌入头套的带子中,用于客观测量佩戴时间。为了测量牙齿的移动,以上颚为参考区域,将治疗前和治疗后的数字模型叠加在一起;沿着三个轴线测量平移和旋转。使用 Viewbox 4 软件进行叠加和移动测量:平均治疗时间和头套佩戴时间分别为 130 天和 55 天,即每天 10.1 小时。在此期间,远端移动平均为 1.75 毫米,但变化很大(最小 0.2 毫米,最大 4.5 毫米)。远端倾斜和旋转的平均温度约为 5 °C。头套的累积佩戴量与远端移动量有显著相关性(r2 = 0.32,P 结论:顺应性对于取得成功的临床结果至关重要。使用颈式矫治器进行磨牙远端矫治与矫治器的累计使用时间相关,而每天的使用时间则是一个较弱的预测因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Cervical headgear effectiveness in distalizing molars in relation to patient compliance.

Objectives: The purpose of this study was to measure the effectiveness of the cervical headgear for distalizing first permanent maxillary molars in relation to hours of use.

Methods: This was a one-centre, prospective, clinical study conducted at the Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece. Participants (N = 26; 17 females, 9 males) were patients with no history of orthodontic treatment, no syndromes or clefts, and Angle's Class II malocclusion, where the treatment plan included a cervical headgear. They were instructed to wear the appliance for at least 12 h per day. A TheraMon® microsensor was embedded in the headgear's strap to objectively measure wear-time. To measure tooth movement, pre- and post-treatment digital models were superimposed, using the palate as a reference area; translation and rotation were measured along three axes. Superimposition and movement measurements were made with the Viewbox 4 software.

Results: Average treatment time and headgear wear were 130 days and 55 days, respectively, i.e. 10.1 h/day. During this period, distal movement averaged 1.75 mm with high variability (min 0.2 mm, max 4.5 mm). Distal tipping and rotation had an average of approximately 5 °C. Cumulative headgear wear was significantly correlated with distal movement (r2 = 0.32, P < .002), distal tipping (r2 = 0.27, P < .01), and distal rotation around the long axis of the tooth (r2 = 0.20, P < .05).

Conclusion: Compliance is critical for having a successful clinical outcome. Distalization of the molar with a cervical headgear is correlated with the cumulative hours of appliance use, with hours per day being a weaker predictor.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European journal of orthodontics
European journal of orthodontics 医学-牙科与口腔外科
CiteScore
5.50
自引率
7.70%
发文量
71
审稿时长
4-8 weeks
期刊介绍: The European Journal of Orthodontics publishes papers of excellence on all aspects of orthodontics including craniofacial development and growth. The emphasis of the journal is on full research papers. Succinct and carefully prepared papers are favoured in terms of impact as well as readability.
期刊最新文献
Clinical risk factors caused by third molar levelling following extraction of a mandibular second molar. Does incisor inclination change during orthodontic treatment affect gingival thickness and the width of keratinized gingiva? A prospective controlled study. Roles of B-cell lymphoma 6 in orthodontic tooth movement of rat molars. Influence of genetic and environmental factors on transverse growth. The effect of micro-osteoperforation (MOP) in molar distalization treatments: an exploratory systematic review and meta-analysis of RCTs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1