大流量麻醉给药系统及其应用。

M Takahashi, A Ishida, H Toyooka, K Amaha
{"title":"大流量麻醉给药系统及其应用。","authors":"M Takahashi,&nbsp;A Ishida,&nbsp;H Toyooka,&nbsp;K Amaha","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Microcomputer-based anesthesia delivery system using mass flow control devices has been developed. System is superior in computer control to conventional anesthesia machine because there is no mechanical setting. System consists of three thermal mass flow controllers (TMFC), one vapor source controller (VSC), personal computer system, and air circuits. Personal computer system has facilities of digital output, analogue input and analogue output interfaces. TMFCs and VSC are devices which operational principle is based on the thermal conductance and they are controlled by electrical signals from computer in the system. TMFCs control the mass flow of nitrous oxide, oxygen and carbon oxide according to each input voltage signal. VSC regulates mass vapor of halothane in order to keep set value up by means of alteration of oxygen carrier gas flow. Computer always monitors the gas flow of the TMFCs and VSC so that computer compensates the change of the carrier gas flow of VSC by regulating the TMFC for oxygen. Mixed gas from TMFCs and VSC is supplied through the air circuit to subject. Characteristics of the system was measured by mass spectrometer and flowmeter. Stability was 0.05% change after 30 minutes at the initial set of 3%. Experiment on animals using mongrel dogs has been performed to verify the system functions.</p>","PeriodicalId":75957,"journal":{"name":"Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering","volume":"27 1","pages":"19-25"},"PeriodicalIF":0.0000,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Mass flow anesthesia delivery system and its application].\",\"authors\":\"M Takahashi,&nbsp;A Ishida,&nbsp;H Toyooka,&nbsp;K Amaha\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Microcomputer-based anesthesia delivery system using mass flow control devices has been developed. System is superior in computer control to conventional anesthesia machine because there is no mechanical setting. System consists of three thermal mass flow controllers (TMFC), one vapor source controller (VSC), personal computer system, and air circuits. Personal computer system has facilities of digital output, analogue input and analogue output interfaces. TMFCs and VSC are devices which operational principle is based on the thermal conductance and they are controlled by electrical signals from computer in the system. TMFCs control the mass flow of nitrous oxide, oxygen and carbon oxide according to each input voltage signal. VSC regulates mass vapor of halothane in order to keep set value up by means of alteration of oxygen carrier gas flow. Computer always monitors the gas flow of the TMFCs and VSC so that computer compensates the change of the carrier gas flow of VSC by regulating the TMFC for oxygen. Mixed gas from TMFCs and VSC is supplied through the air circuit to subject. Characteristics of the system was measured by mass spectrometer and flowmeter. Stability was 0.05% change after 30 minutes at the initial set of 3%. Experiment on animals using mongrel dogs has been performed to verify the system functions.</p>\",\"PeriodicalId\":75957,\"journal\":{\"name\":\"Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering\",\"volume\":\"27 1\",\"pages\":\"19-25\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研制了一种采用质量流量控制装置的微机麻醉输送系统。该系统无机械设置,在计算机控制方面优于传统麻醉机。系统由三个热质量流量控制器(TMFC)、一个蒸气源控制器(VSC)、个人计算机系统和空气回路组成。个人计算机系统具有数字输出、模拟输入和模拟输出接口。tmfc和VSC是一种以热导率为工作原理,由系统中计算机发出的电信号控制的器件。tmfc根据每个输入电压信号控制氧化亚氮、氧和氧化碳的质量流量。VSC通过改变载氧气体流量来调节氟烷的质量蒸气,使其保持设定值。计算机时刻监测TMFC和VSC的气体流量,通过调节TMFC供氧量来补偿VSC载气流量的变化。来自tmfc和VSC的混合气体通过空气回路供应给受试者。采用质谱仪和流量计对系统进行了特性测试。在初始浓度为3%的情况下,30分钟后稳定性为0.05%。利用杂种狗进行了动物实验,验证了系统的功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Mass flow anesthesia delivery system and its application].

Microcomputer-based anesthesia delivery system using mass flow control devices has been developed. System is superior in computer control to conventional anesthesia machine because there is no mechanical setting. System consists of three thermal mass flow controllers (TMFC), one vapor source controller (VSC), personal computer system, and air circuits. Personal computer system has facilities of digital output, analogue input and analogue output interfaces. TMFCs and VSC are devices which operational principle is based on the thermal conductance and they are controlled by electrical signals from computer in the system. TMFCs control the mass flow of nitrous oxide, oxygen and carbon oxide according to each input voltage signal. VSC regulates mass vapor of halothane in order to keep set value up by means of alteration of oxygen carrier gas flow. Computer always monitors the gas flow of the TMFCs and VSC so that computer compensates the change of the carrier gas flow of VSC by regulating the TMFC for oxygen. Mixed gas from TMFCs and VSC is supplied through the air circuit to subject. Characteristics of the system was measured by mass spectrometer and flowmeter. Stability was 0.05% change after 30 minutes at the initial set of 3%. Experiment on animals using mongrel dogs has been performed to verify the system functions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Society reports and conferences The International Institute for Medical Electronics and Biological Engineering Current applications of fiber optics to fluoroscopy Femur measuring device The international institute—Its relationship to national and regional institutes in medical electronics and biological engineering
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1