佩戴悬挂销钉的经胫假肢使用者的远端负重情况

IF 1.3 Q3 REHABILITATION Frontiers in rehabilitation sciences Pub Date : 2023-12-21 DOI:10.3389/fresc.2023.1322202
Adam J Krout, Mathew J. Weissinger, J. Mertens, Katheryn J Allyn, B. Larsen, Nicholas K. McCarthy, J. Garbini, Joan E Sanders
{"title":"佩戴悬挂销钉的经胫假肢使用者的远端负重情况","authors":"Adam J Krout, Mathew J. Weissinger, J. Mertens, Katheryn J Allyn, B. Larsen, Nicholas K. McCarthy, J. Garbini, Joan E Sanders","doi":"10.3389/fresc.2023.1322202","DOIUrl":null,"url":null,"abstract":"Low-level distal weight bearing in transtibial prosthesis users may help maintain perfusion and improve both proprioception and residual limb tissue health.The primary objectives of this research were to develop a sensor to continuously measure distal weight bearing, evaluate how prosthesis design variables affected weight bearing levels, and assess fluctuations in distal weight bearing during at-home and community use.In-lab testing on a small group of participants wearing adjustable sockets demonstrated that if distal contact was present, when socket size was increased distal weight bearing increased and when socket size was reduced distal weight bearing decreased. During take-home use, participants accepted the distal weight bearing level set by the research team. It ranged between 1.1% and 6.4% BW for all days tested. The coefficient of variation (standard deviation/mean) ranged from 25% to 43% and was expected due in part to differences in walking style, speed, terrain, direction of ambulation, and bout duration. Two participants commented that they preferred presence of distal weight bearing to non-presence.Next steps in this research are to develop clinical practices to determine target distal weight bearing levels and ranges, and to simplify the design of the sensor and weight bearing adjustment mechanism for clinical use.","PeriodicalId":73102,"journal":{"name":"Frontiers in rehabilitation sciences","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Distal weight bearing in transtibial prosthesis users wearing pin suspension\",\"authors\":\"Adam J Krout, Mathew J. Weissinger, J. Mertens, Katheryn J Allyn, B. Larsen, Nicholas K. McCarthy, J. Garbini, Joan E Sanders\",\"doi\":\"10.3389/fresc.2023.1322202\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Low-level distal weight bearing in transtibial prosthesis users may help maintain perfusion and improve both proprioception and residual limb tissue health.The primary objectives of this research were to develop a sensor to continuously measure distal weight bearing, evaluate how prosthesis design variables affected weight bearing levels, and assess fluctuations in distal weight bearing during at-home and community use.In-lab testing on a small group of participants wearing adjustable sockets demonstrated that if distal contact was present, when socket size was increased distal weight bearing increased and when socket size was reduced distal weight bearing decreased. During take-home use, participants accepted the distal weight bearing level set by the research team. It ranged between 1.1% and 6.4% BW for all days tested. The coefficient of variation (standard deviation/mean) ranged from 25% to 43% and was expected due in part to differences in walking style, speed, terrain, direction of ambulation, and bout duration. Two participants commented that they preferred presence of distal weight bearing to non-presence.Next steps in this research are to develop clinical practices to determine target distal weight bearing levels and ranges, and to simplify the design of the sensor and weight bearing adjustment mechanism for clinical use.\",\"PeriodicalId\":73102,\"journal\":{\"name\":\"Frontiers in rehabilitation sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-12-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in rehabilitation sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3389/fresc.2023.1322202\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in rehabilitation sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fresc.2023.1322202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

摘要

这项研究的主要目的是开发一种传感器来连续测量远端负重,评估假肢设计变量对负重水平的影响,以及评估在家中和社区使用假肢时远端负重的波动情况。对一小部分佩戴可调节插座的参与者进行的实验室内测试表明,如果存在远端接触,当插座尺寸增大时,远端负重增加,而当插座尺寸减小时,远端负重减少。在带回家使用的过程中,参与者接受了研究小组设定的远端负重水平。在所有测试天数中,远端负重水平介于 1.1% 和 6.4% 体重之间。变异系数(标准偏差/平均值)介于 25% 到 43% 之间,这在一定程度上是由于行走方式、速度、地形、行走方向和持续时间的差异造成的。本研究的下一步工作是开发临床实践,以确定目标远端负重水平和范围,并简化传感器和负重调节机制的设计,以满足临床使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Distal weight bearing in transtibial prosthesis users wearing pin suspension
Low-level distal weight bearing in transtibial prosthesis users may help maintain perfusion and improve both proprioception and residual limb tissue health.The primary objectives of this research were to develop a sensor to continuously measure distal weight bearing, evaluate how prosthesis design variables affected weight bearing levels, and assess fluctuations in distal weight bearing during at-home and community use.In-lab testing on a small group of participants wearing adjustable sockets demonstrated that if distal contact was present, when socket size was increased distal weight bearing increased and when socket size was reduced distal weight bearing decreased. During take-home use, participants accepted the distal weight bearing level set by the research team. It ranged between 1.1% and 6.4% BW for all days tested. The coefficient of variation (standard deviation/mean) ranged from 25% to 43% and was expected due in part to differences in walking style, speed, terrain, direction of ambulation, and bout duration. Two participants commented that they preferred presence of distal weight bearing to non-presence.Next steps in this research are to develop clinical practices to determine target distal weight bearing levels and ranges, and to simplify the design of the sensor and weight bearing adjustment mechanism for clinical use.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
0
期刊最新文献
SONOICE! a Sonar-Voice dynamic user interface for assisting individuals with blindness and visual impairment in pinpointing elements in 2D tactile readers. Innovative approaches for managing patients with chronic vestibular disorders: follow-up indicators and predictive markers for studying the vestibular error signal. Recommendations for clinical decision-making when offering exoskeletons for community use in individuals with spinal cord injury. Editorial: Rehabilitation, communication disorders and person-family-centered care. Person-centered aural rehabilitation program improved mood, cognition, and auditory processing in a professional musician who uses a hearing aid and cochlear implant: Case Report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1